In an integrated structure low resistance CICC joint, current is conducted by outer cable strands coming into touch with the conductive Cu sole. So it is an important condition for satisfying joint performance that ea...In an integrated structure low resistance CICC joint, current is conducted by outer cable strands coming into touch with the conductive Cu sole. So it is an important condition for satisfying joint performance that each strand of the cable inside the joint is able to come to the outermost by transposition. This paper presents analysis, calculation and figures for the strand transposition. According to the twist procedures of the superconducting cable, the author computed the actual pitch of each stage cable, consecutively computed the projection of each stage cable on the axis of the cable (z axis) and the corresponding twist angle as the z coordinate changes, which is then drawn by AutoCAD. From the results shown in the figures, the minimal cable length, which enables each strand to transpose almost equally to the outermost of the cable in such a length, call be determined as the optimal joint length.展开更多
The oscillating voltage test is a nondestructive detection method for partial discharge of XLPE (cross linked polyethylene) cable and has been applied recently. This paper made three kinds of varying severity artifi...The oscillating voltage test is a nondestructive detection method for partial discharge of XLPE (cross linked polyethylene) cable and has been applied recently. This paper made three kinds of varying severity artificial defect models of cable joints in 10 kV XLPE cable. Oscillating voltage is applied to the model, by use of pulse current method to detect partial discharge signals. In order to study the statistical characteristics of partial discharge of cable joint under the oscillating voltage, three-dimensional statistical map has been made. The results show that for the same kind of defects, with the increases of the defect severity, the discharge interval extended, the magnitude and the number of partial discharge increase, for different kinds of defects, obvious differences exist among the maps, this may established a foundation for the further study of the partial discharge pattern recognition of XLPE cable under oscillating voltage.展开更多
文摘In an integrated structure low resistance CICC joint, current is conducted by outer cable strands coming into touch with the conductive Cu sole. So it is an important condition for satisfying joint performance that each strand of the cable inside the joint is able to come to the outermost by transposition. This paper presents analysis, calculation and figures for the strand transposition. According to the twist procedures of the superconducting cable, the author computed the actual pitch of each stage cable, consecutively computed the projection of each stage cable on the axis of the cable (z axis) and the corresponding twist angle as the z coordinate changes, which is then drawn by AutoCAD. From the results shown in the figures, the minimal cable length, which enables each strand to transpose almost equally to the outermost of the cable in such a length, call be determined as the optimal joint length.
文摘The oscillating voltage test is a nondestructive detection method for partial discharge of XLPE (cross linked polyethylene) cable and has been applied recently. This paper made three kinds of varying severity artificial defect models of cable joints in 10 kV XLPE cable. Oscillating voltage is applied to the model, by use of pulse current method to detect partial discharge signals. In order to study the statistical characteristics of partial discharge of cable joint under the oscillating voltage, three-dimensional statistical map has been made. The results show that for the same kind of defects, with the increases of the defect severity, the discharge interval extended, the magnitude and the number of partial discharge increase, for different kinds of defects, obvious differences exist among the maps, this may established a foundation for the further study of the partial discharge pattern recognition of XLPE cable under oscillating voltage.