A new fiber optic hydrophone is described. based on a distributed feedback fiber laser (DFB-fiber laser) Experimental arrangement consists of DFB-FL, unbalanced Mach-Zehnder interferometer, piezoelectric (PZT) modulat...A new fiber optic hydrophone is described. based on a distributed feedback fiber laser (DFB-fiber laser) Experimental arrangement consists of DFB-FL, unbalanced Mach-Zehnder interferometer, piezoelectric (PZT) modulator, detection and feedback control circuit, and oscillograph. Experimental results show that the bare DFB-FL hydrophone is extremely sensitive to small perturbations in their environment and can acquire exact acoustic signals.展开更多
Supercontinuum(SC) generation in a dispersion-shifted fiber(DSF) pumped by a 10 GHz regeneratively mode-locked fiber laser(RMLFL) is presented.Optimization of pump wavelength leads to a 20 dB bandwidth of 58.73 nm,whi...Supercontinuum(SC) generation in a dispersion-shifted fiber(DSF) pumped by a 10 GHz regeneratively mode-locked fiber laser(RMLFL) is presented.Optimization of pump wavelength leads to a 20 dB bandwidth of 58.73 nm,which covers the whole C band and part of L band.Using an angle-tuning thin film filter,multi-wavelength and pico-second pulse trains of low chirp could be chosen from the SC spectrum.Amplified spontaneous emission(ASE) induced degeneration of the achieved pulse trains is observed and discussed.展开更多
Objective:To investigate the value of optic disc retinal nerve fiber layer(RNFL)thickness in the diagnosis of diabetic peripheral neuropathy(DPN).Methods:Ninety patients with type 2 diabetes,including 60 patients with...Objective:To investigate the value of optic disc retinal nerve fiber layer(RNFL)thickness in the diagnosis of diabetic peripheral neuropathy(DPN).Methods:Ninety patients with type 2 diabetes,including 60 patients without DPN(NDPN group)and 30 patients with DPN(DPN group),and 30 healthy participants(normal group)were enrolled.Optical coherence tomography(OCT)was used to measure the four quadrants and the overall average RNFL thickness of the optic disc.The receiver operator characteristic curve was drawn and the area under the curve(AUC)was calculated to evaluate the diagnostic value of RNFL thickness in the optic disc area for DPN.Results:The RNFL thickness of the DPN group was thinner than those of the normal and NDPN groups in the overall average((101.07±12.40)μm vs.(111.07±6.99)μm and(109.25±6.90)μm),superior quadrant((123.00±19.04)μm vs.(138.93±14.16)μm and(134.47±14.34)μm),and inferior quadrant((129.37±17.50)μm vs.(143.60±12.22)μm and(144.48±14.10)μm),and the differences were statistically significant.The diagnostic efficiencies of the overall average,superior quadrant,and inferior quadrant RNFL thicknesses,and a combined index of superior and inferior quadrant RNFL thicknesses were similar,and the AUCs were 0.739(95%confidence interval(CI)0.635–0.826),0.683(95%CI 0.576–0.778),0.755(95%CI 0.652–0.840),and 0.773(95%CI 0.672–0.854),respectively.The diagnostic sensitivity of RNFL thickness in the superior quadrant reached 93.33%.Conclusions:The thickness of the RNFL in the optic disc can be used as a diagnostic method for DPN.展开更多
基金Supported by China Scholarship Council, Natural Science Foun-dation of China (grant no.NSFC 60677027)Natural Science Foun-dation of Shandong Province of China (grant no.Y2006G08)Foundation for Doctoral Research of Shandong Academy of Sci-ence (grant no.2005-79).
文摘A new fiber optic hydrophone is described. based on a distributed feedback fiber laser (DFB-fiber laser) Experimental arrangement consists of DFB-FL, unbalanced Mach-Zehnder interferometer, piezoelectric (PZT) modulator, detection and feedback control circuit, and oscillograph. Experimental results show that the bare DFB-FL hydrophone is extremely sensitive to small perturbations in their environment and can acquire exact acoustic signals.
基金Supperted by National Natural Science Foundation of China(No.60477022)
文摘Supercontinuum(SC) generation in a dispersion-shifted fiber(DSF) pumped by a 10 GHz regeneratively mode-locked fiber laser(RMLFL) is presented.Optimization of pump wavelength leads to a 20 dB bandwidth of 58.73 nm,which covers the whole C band and part of L band.Using an angle-tuning thin film filter,multi-wavelength and pico-second pulse trains of low chirp could be chosen from the SC spectrum.Amplified spontaneous emission(ASE) induced degeneration of the achieved pulse trains is observed and discussed.
基金the Science and Technology Plan Project of Quanzhou(Nos.2018Z114,2018Z115,and 2019N104S)the Qihang Fund of Fujian Medical University(No.2016QH072)the Health Research Talent Training Project of Fujian(No.2019-ZQN-66),China。
文摘Objective:To investigate the value of optic disc retinal nerve fiber layer(RNFL)thickness in the diagnosis of diabetic peripheral neuropathy(DPN).Methods:Ninety patients with type 2 diabetes,including 60 patients without DPN(NDPN group)and 30 patients with DPN(DPN group),and 30 healthy participants(normal group)were enrolled.Optical coherence tomography(OCT)was used to measure the four quadrants and the overall average RNFL thickness of the optic disc.The receiver operator characteristic curve was drawn and the area under the curve(AUC)was calculated to evaluate the diagnostic value of RNFL thickness in the optic disc area for DPN.Results:The RNFL thickness of the DPN group was thinner than those of the normal and NDPN groups in the overall average((101.07±12.40)μm vs.(111.07±6.99)μm and(109.25±6.90)μm),superior quadrant((123.00±19.04)μm vs.(138.93±14.16)μm and(134.47±14.34)μm),and inferior quadrant((129.37±17.50)μm vs.(143.60±12.22)μm and(144.48±14.10)μm),and the differences were statistically significant.The diagnostic efficiencies of the overall average,superior quadrant,and inferior quadrant RNFL thicknesses,and a combined index of superior and inferior quadrant RNFL thicknesses were similar,and the AUCs were 0.739(95%confidence interval(CI)0.635–0.826),0.683(95%CI 0.576–0.778),0.755(95%CI 0.652–0.840),and 0.773(95%CI 0.672–0.854),respectively.The diagnostic sensitivity of RNFL thickness in the superior quadrant reached 93.33%.Conclusions:The thickness of the RNFL in the optic disc can be used as a diagnostic method for DPN.