In order to evaluate the effects of structural control and energy transition for the base-isolation with energy transducer (BIET), shaking table tests on a steel frame model (BIET system) with scale of 1:4 were c...In order to evaluate the effects of structural control and energy transition for the base-isolation with energy transducer (BIET), shaking table tests on a steel frame model (BIET system) with scale of 1:4 were conducted and the results were compared with the lead rubber beating (LRB) isolation system for the same model. Then numerical analysis of the system was carried out, in which the improved Wen analytic model was used to simulate the hysteretic law of transducers. The results show that the structural system can transform the partial earthquake energy to hydraulic energy ; furthermore, the effect of structural control can reach or be close to that of the LRB isolation system. The agreements between numerical analysis results and those of shaking table tests demonstrate the accuracy of the numerical model.展开更多
By analyzing the correlation between modal calculations and modal experiments of a typical supporter, an effective finite element analysis( FEA)model of the actual aerospace supporter is created. According to the anal...By analyzing the correlation between modal calculations and modal experiments of a typical supporter, an effective finite element analysis( FEA)model of the actual aerospace supporter is created. According to the analysis of constrained viscoelastic damping, the strategies of PVC have been worked out, and the correlation between modal calculations and modal experiments of the supporter has also been computed, and then, an experiment has been designed based on the calculation results. The results of experiments verify that the PVC strategy can effectively suppress vibration.展开更多
The grid-connected inverter with LCL filter has the ability of easily attenuating high-frequency current harmonics. However, its suppression effect on the background harmonics in grid voltage is limited. A control str...The grid-connected inverter with LCL filter has the ability of easily attenuating high-frequency current harmonics. However, its suppression effect on the background harmonics in grid voltage is limited. A control strategy is presented, which is composed of an inner loop of capacitor current feedforward, an outer loop of grid-current feedforward and feedforward of grid voltage. The limitations and steps of parameters design for LCL filter are analyzed. Meanwhile, the capacitor current loop is employed to damp the resonant peak caused by the LCL filter and enhance the stability. The properties of different controllers are analyzed and compared, thereinto quasi-proportional-rasonant (PR) controller realizes the control with zero steady-state error of AC variables in static coordinates. In order to suppress the current distortion effected by the background harmonics in grid voltage, the feed-forward function is calculated for the grid-connected inverter with an LCL filter. After simplifying the block diagram, a full-feedforward control strategy for grid voltage is proposed. Theoretical analysis and Matlab/Simulink simulation results show that the proposed method has the advantages of high steady accuracy, fast dynamic response and strong robustness.展开更多
Digital control of a general-purpose switching power supply is one of the key technologies to perform the high reliability and the intelligent function demanded for the next generation. The contribution of this paper ...Digital control of a general-purpose switching power supply is one of the key technologies to perform the high reliability and the intelligent function demanded for the next generation. The contribution of this paper is the development of a digital control-based switching power supply. In the developed system, the generation method of the optimal voltage reference to eliminate the limit cycle oscillation of output voltage due to the AD/DA resolution is proposed. In the proposed method, the variation of the input power source voltage can be also compensated. The effectiveness of the proposed optimal reference generation method is experimentally verified.展开更多
The 3rd generation synchrotron light source requires high level of electron beam orbit stability.Shanghai Synchrotron Radiation Facility (SSRF) is a 3rd generation light source under construction;its orbit stability r...The 3rd generation synchrotron light source requires high level of electron beam orbit stability.Shanghai Synchrotron Radiation Facility (SSRF) is a 3rd generation light source under construction;its orbit stability requirement is up to micro or sub-micro range.The storage ring mechanical components vibration caused by the ground motion would influence the orbit stability.The ground motion of SSRF is severe.It is essential to control the vibration of the mechanical components.Vibration damping is an effective method to control the vibration.The author designed a vibration damping structure for the SSRF mechanical components.The test results show that it can effectively control the mechanical vibration.展开更多
基金Sponsored by the Hebei Scientific and Technological Research and Development Plans (Grant No.07215615)
文摘In order to evaluate the effects of structural control and energy transition for the base-isolation with energy transducer (BIET), shaking table tests on a steel frame model (BIET system) with scale of 1:4 were conducted and the results were compared with the lead rubber beating (LRB) isolation system for the same model. Then numerical analysis of the system was carried out, in which the improved Wen analytic model was used to simulate the hysteretic law of transducers. The results show that the structural system can transform the partial earthquake energy to hydraulic energy ; furthermore, the effect of structural control can reach or be close to that of the LRB isolation system. The agreements between numerical analysis results and those of shaking table tests demonstrate the accuracy of the numerical model.
基金Sponsored by the National 863 Project of China (Grant No. 863 -2 -416)
文摘By analyzing the correlation between modal calculations and modal experiments of a typical supporter, an effective finite element analysis( FEA)model of the actual aerospace supporter is created. According to the analysis of constrained viscoelastic damping, the strategies of PVC have been worked out, and the correlation between modal calculations and modal experiments of the supporter has also been computed, and then, an experiment has been designed based on the calculation results. The results of experiments verify that the PVC strategy can effectively suppress vibration.
基金National Natural Science Foundation of China(No.51767014)China Railway Corporation of Science and Technology Research and Development Projects(No.2016J010-C)
文摘The grid-connected inverter with LCL filter has the ability of easily attenuating high-frequency current harmonics. However, its suppression effect on the background harmonics in grid voltage is limited. A control strategy is presented, which is composed of an inner loop of capacitor current feedforward, an outer loop of grid-current feedforward and feedforward of grid voltage. The limitations and steps of parameters design for LCL filter are analyzed. Meanwhile, the capacitor current loop is employed to damp the resonant peak caused by the LCL filter and enhance the stability. The properties of different controllers are analyzed and compared, thereinto quasi-proportional-rasonant (PR) controller realizes the control with zero steady-state error of AC variables in static coordinates. In order to suppress the current distortion effected by the background harmonics in grid voltage, the feed-forward function is calculated for the grid-connected inverter with an LCL filter. After simplifying the block diagram, a full-feedforward control strategy for grid voltage is proposed. Theoretical analysis and Matlab/Simulink simulation results show that the proposed method has the advantages of high steady accuracy, fast dynamic response and strong robustness.
文摘Digital control of a general-purpose switching power supply is one of the key technologies to perform the high reliability and the intelligent function demanded for the next generation. The contribution of this paper is the development of a digital control-based switching power supply. In the developed system, the generation method of the optimal voltage reference to eliminate the limit cycle oscillation of output voltage due to the AD/DA resolution is proposed. In the proposed method, the variation of the input power source voltage can be also compensated. The effectiveness of the proposed optimal reference generation method is experimentally verified.
文摘The 3rd generation synchrotron light source requires high level of electron beam orbit stability.Shanghai Synchrotron Radiation Facility (SSRF) is a 3rd generation light source under construction;its orbit stability requirement is up to micro or sub-micro range.The storage ring mechanical components vibration caused by the ground motion would influence the orbit stability.The ground motion of SSRF is severe.It is essential to control the vibration of the mechanical components.Vibration damping is an effective method to control the vibration.The author designed a vibration damping structure for the SSRF mechanical components.The test results show that it can effectively control the mechanical vibration.