Energy performance assessment on central air-conditioning system is essential to optimize operating, reduce operating costs, improve indoor environmental quality, and determine whether the retrofitting of the equipmen...Energy performance assessment on central air-conditioning system is essential to optimize operating, reduce operating costs, improve indoor environmental quality, and determine whether the retrofitting of the equipment is necessary. But it is difficult to evaluate it reasonably and comprehensively due to its complexity. A "holistic" approach was discussed to evaluate the energy performance of central air-conditioning system for an extra-large commercial building in a subtropical city. All procedures were described in detail, including field investigation method, field measurement instruments, data processing and data analyzing. The main factors affecting energy consumption of air-conditioning system were analyzed and the annual cooling-energy use intensity of this building was calculated and also compared with other shopping malls and other types of buildings in Guangzhou. And COP(coefficient of performance) of chiller, water transfer factor of chilled water system and cooling water system were taken into consideration. At last, the thermal comfort and indoor air quality issues were addressed. The results show that the chilled water pumps are over-sized and the indoor environmental quality should be improved. The purpose of this work is to provide reference for energy performance assessment method for air-conditioning system.展开更多
Passive strategies for acclimatization of buildings have been studied by several authors in many countries, especially the evaporative and radiant cooling techniques. Fiber cement tiles are very common in popular cons...Passive strategies for acclimatization of buildings have been studied by several authors in many countries, especially the evaporative and radiant cooling techniques. Fiber cement tiles are very common in popular constructions due to their low cost. However, they have over twice of the value thermal transmittance indicated to this bioclimatic zone according to Brazilian guidelines. The objective is to present an alternative to reduce high temperatures on fiber cement tiles. In this paper, the monitoring of passive cooling of roofing during the spring season in a city with subtropical climate is described. Single and combined reflective and evaporative cooling systems were studied in different environmental conditions. Internal surface temperatures of tiles were monitored together with weather variables. Results show a decrease of about 6 ℃, 9 ℃, 10 ℃ and 11 ℃ as compared to the original tiles according to environment conditions and the combined passive cooling techniques. These results allow for the conclusion that the use of passive cooling techniques opens up new possibilities to attenuate the internal surface temperatures of tiles and to consequently decrease the roofing solar heat gain into buildings, thus, providing less air cooling energy consumption.展开更多
基金Project(2011B061200043)supported by the Guangdong Provincial Department of Science and Technology,China
文摘Energy performance assessment on central air-conditioning system is essential to optimize operating, reduce operating costs, improve indoor environmental quality, and determine whether the retrofitting of the equipment is necessary. But it is difficult to evaluate it reasonably and comprehensively due to its complexity. A "holistic" approach was discussed to evaluate the energy performance of central air-conditioning system for an extra-large commercial building in a subtropical city. All procedures were described in detail, including field investigation method, field measurement instruments, data processing and data analyzing. The main factors affecting energy consumption of air-conditioning system were analyzed and the annual cooling-energy use intensity of this building was calculated and also compared with other shopping malls and other types of buildings in Guangzhou. And COP(coefficient of performance) of chiller, water transfer factor of chilled water system and cooling water system were taken into consideration. At last, the thermal comfort and indoor air quality issues were addressed. The results show that the chilled water pumps are over-sized and the indoor environmental quality should be improved. The purpose of this work is to provide reference for energy performance assessment method for air-conditioning system.
文摘Passive strategies for acclimatization of buildings have been studied by several authors in many countries, especially the evaporative and radiant cooling techniques. Fiber cement tiles are very common in popular constructions due to their low cost. However, they have over twice of the value thermal transmittance indicated to this bioclimatic zone according to Brazilian guidelines. The objective is to present an alternative to reduce high temperatures on fiber cement tiles. In this paper, the monitoring of passive cooling of roofing during the spring season in a city with subtropical climate is described. Single and combined reflective and evaporative cooling systems were studied in different environmental conditions. Internal surface temperatures of tiles were monitored together with weather variables. Results show a decrease of about 6 ℃, 9 ℃, 10 ℃ and 11 ℃ as compared to the original tiles according to environment conditions and the combined passive cooling techniques. These results allow for the conclusion that the use of passive cooling techniques opens up new possibilities to attenuate the internal surface temperatures of tiles and to consequently decrease the roofing solar heat gain into buildings, thus, providing less air cooling energy consumption.