期刊文献+
共找到1,349篇文章
< 1 2 68 >
每页显示 20 50 100
Wind-induced vibration of single-layer reticulated shell structures
1
作者 张建胜 武岳 沈世钊 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2008年第4期494-498,共5页
Aiming at the dynamic response of reticulated shell structures under wind load,systematic parameter analyses on wind-induced responses of Kiewitt6-6 type single-layer spherical reticulated shell structures and three-w... Aiming at the dynamic response of reticulated shell structures under wind load,systematic parameter analyses on wind-induced responses of Kiewitt6-6 type single-layer spherical reticulated shell structures and three-way grid single-layer cylindrical reticulated shell structures were performed with the random simulation method in time domain,including geometric parameters,structural parameters and aerodynamic parameters.Moreover,a wind-induced vibration coefficient was obtained,which can be a reference to the wind-resistance design of reticulated shell structures.The results indicate that the geometric parameters are the most important factor influencing wind-induced responses of the reticulated shell structures;the wind-induced vibration coeffi-cient is 3.0-3.2 for the spherical reticulated shell structures and that is 2.8-3.0 for the cylindrical reticula-ted shell structures,which shows that the wind-induced vibration coefficients of these two kinds of space frames are well-proportioned. 展开更多
关键词 reticulated shell structures wind-induced response random simulation method in time domain wind-induced vibration coefficient
在线阅读 下载PDF
Wind-induced vibration control of bridges using liquid column damper 被引量:3
2
作者 薛素铎 高赞明 徐幼麟 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2002年第2期271-280,共10页
The potential application of tuned liquid column damper (TLCD) for suppressing wind-induced vibration of long span bridges is explored in this paper.By installing the TLCD in the bridge deck,a mathematical model for t... The potential application of tuned liquid column damper (TLCD) for suppressing wind-induced vibration of long span bridges is explored in this paper.By installing the TLCD in the bridge deck,a mathematical model for the bridge-TLCD system is established.The governing equations of the system are developed by considering all three displacement components of the deck in vertical,lateral,and torsional vibrations,in which the interactions between the bridge deck,the TLCD,the aeroelastic forces,and the aerodynamic forces are fully reflected.Both buffeting and flutter analyses are carried out.The buffeting analysis is performed through random vibration approach,and a critical flutter condition is identified from flutter analysis.A numerical example is presented to demonstrate the control effectiveness of the damper and it is shown that the TLCD can be an effective device for suppressing wind-induced vibration of long span bridges,either for reducing the buffeting response or increasing the critical flutter wind velocity of the bridge. 展开更多
关键词 long span bridge bridge deck wind-induced vibration vibration control FLUTTER BUFFETING tuned liquid column damper TLCD-bridge interaction mathematical model
在线阅读 下载PDF
Forced Axial and Torsional Vibrations of a Shaft Line Using the Transfer Matrix Method Related to Solution Coefficients 被引量:2
3
作者 Kandouci Chahr-Eddine Adjal Yassine 《Journal of Marine Science and Application》 2014年第2期200-205,共6页
This present paper deals with a mathematical description of linear axial and torsional vibrations. The normal and tangential stress tensor components produced by axial-torsional deformations and vibrations in the prop... This present paper deals with a mathematical description of linear axial and torsional vibrations. The normal and tangential stress tensor components produced by axial-torsional deformations and vibrations in the propeller and intermediate shafts, under the influence of propeller-induced static and variable hydrodynamic excitations are also studied. The transfer matrix method related to the constant coefficients of differential equation solutions is used. The advantage of the latter as compared with a well-known method of transfer matrix associated with state vector is the possibility of reducing the number of multiplied matrices when adjacent shaft segments have the same material properties and diameters. The results show that there is no risk of buckling and confirm that the strength of the shaft line depends on the value of the static tangential stresses which is the most important component of the stress tensor. 展开更多
关键词 shaft line stress tensor vibration axial vibration torsional vibration transfer matrix constant coefficient vector
在线阅读 下载PDF
Wind-Induced Vibration Control for Substation Frame on Viscous Damper 被引量:1
4
作者 Bingji Lan Kanghao Yan 《Computers, Materials & Continua》 SCIE EI 2020年第3期1303-1315,共13页
In order to study the wind-induced vibration control effect of the viscous damper on the large-scale substation frame,this paper takes the large-scale 1000 kV substation frame of western Inner Mongolia as an example.T... In order to study the wind-induced vibration control effect of the viscous damper on the large-scale substation frame,this paper takes the large-scale 1000 kV substation frame of western Inner Mongolia as an example.The time-history sample of pulsating wind load is simulated by harmonic superposition method based on Matlab software.6 kinds of viscous damper arrangement schemes have been designed,and SAP2000 finite element software is used for fine modeling and input wind speed time history load for nonlinear time history analysis.The displacement and acceleration of a typical node are the indicators of wind vibration control.The wind-induced vibration control effects of different schemes under different damping parameters have compared,and the damping parameters are analyzed for the optimal layout scheme.The results show that a viscous damper has installed in the lower layers of the substation;a viscous damper is placed between the ground column and the lattice beam.It is an integrated optimal solution.The wind-induced vibration control effect of the optimal scheme is sensitive to the viscous damper parameters,and the control effect does not increase linearly with the increase of the damping index and the damping coefficient.Corresponding to different damping indexes,the damping coefficient has a better range of values. 展开更多
关键词 Viscous damper wind-induced vibration control arrangement plan damping coefficient damping index
在线阅读 下载PDF
Reduction of Cogging Torque and Electromagnetic Vibration Based on Different Combination of Pole Arc Coefficient for Interior Permanent Magnet Synchronous Machine 被引量:10
5
作者 Feng Liu Xiuhe Wang +2 位作者 Zezhi Xing Aiguo Yu Changbin Li 《CES Transactions on Electrical Machines and Systems》 CSCD 2021年第4期291-300,共10页
Cogging torque and electromagnetic vibration are two important factors for evaluating permanent magnet synchronous machine(PMSM)and are key issues that must be considered and resolved in the design and manufacture of ... Cogging torque and electromagnetic vibration are two important factors for evaluating permanent magnet synchronous machine(PMSM)and are key issues that must be considered and resolved in the design and manufacture of high-performance PMSM for electric vehicles.A fast and accurate magnetic field calculation model for interior permanent magnet synchronous machine(IPMSM)is proposed in this article.Based on the traditional magnetic potential permeance method,the stator cogging effect and complex boundary conditions of the IPMSM can be fully considered in this model,so as to realize the rapid calculation of equivalent magnetomotive force(MMF),air gap permeance,and other key electromagnetic properties.In this article,a 6-pole 36-slot IPMSM is taken as an example to establish its equivalent solution model,thereby the cogging torque is accurately calculated.And the validity of this model is verified by a variety of different magnetic pole structures,pole slot combinations machines,and prototype experiments.In addition,the improvement measure of the machine with different combination of pole arc coefficient is also studied based on this model.Cogging torque and electromagnetic vibration can be effectively weakened.Combined with the finite element model and multi-physics coupling model,the electromagnetic characteristics and vibration performance of this machine are comprehensively compared and analyzed.The analysis results have well verified its effectiveness.It can be extended to other structures or types of PMSM and has very important practical value and research significance. 展开更多
关键词 Cogging torque different combination of pole arc coefficient electromagnetic vibration interior permanent magnet synchronous machine
在线阅读 下载PDF
Wind-induced vibration control of long-span power transmission towers 被引量:1
6
作者 尹鹏 《Journal of Chongqing University》 CAS 2009年第2期112-124,共13页
We investigated wind-induced vibration control of long-span power transmission towers based on a case study of the Jingdongnan-Nanyang-Jingmen 1 000 kV transmission line project in P. R. China. The height of the cup t... We investigated wind-induced vibration control of long-span power transmission towers based on a case study of the Jingdongnan-Nanyang-Jingmen 1 000 kV transmission line project in P. R. China. The height of the cup tower is 181 m with a ground elevation of 47 m, which makes it a super flexible and wind-sensitive structure. Therefore, we should analyze the wind- resistant capacity of the system. We simulated applicable transverse fluctuating wind velocity field, developed a lead-rubber damper (LRD) for controlling wind-induced vibration of long-span transmission towers, deduced LRD calculation model parameter, and researched the best layout scheme and installation method of LRD. To calculate the wind-induced response of tower-line coupling system in seven layout schemes, we used the time history analysis method, and obtained the efficiencies of wind-induced vibration control. LRD deformation research proved that the damp of all LRDs was efficient under the designed wind velocity when they were laid along the edge of tower heads. We studied the controlling efficiency resulting fTom only applying stiffness to the tower polos where the dampers used to be laid under the designed wind velocity. The results show that the controlling efficiency was not ideal when the stiffness is increased on the poles only. Therefore, LRD should conlxibute to both the stiffness and damp of a structure to effectively reduce the dynamic response of a tower-line coupling system under strong winds. We also discussed the controlling efficiency of LRD under static winds. The results show that there was little difference between displacements derived by the finite clement time history method and those obtained by static wind method conducted by a design institute. This means the simulation on space relevant wind velocity field was accurate and reasonable. 展开更多
关键词 transmission towers lead-rubber damper wind-induced vibration control
在线阅读 下载PDF
Case Study of Wind-Induced Vibration of a Cooling Tower Under Typhoon Environment
7
作者 XING Yuan ZHAO Lin +1 位作者 CHEN Xu GE Yaojun 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI CSCD 2020年第1期108-119,共12页
As high-rise cooling towers are constantly emerging,wind effects on this kind of wind-sensitive structures have attracted more and more attention,especially in typhoon prone areas.Terrain Type B turbulent flow fields ... As high-rise cooling towers are constantly emerging,wind effects on this kind of wind-sensitive structures have attracted more and more attention,especially in typhoon prone areas.Terrain Type B turbulent flow fields under the normal wind and typhoon are simulated by active wind tunnel technology,and rigid-pressure-measurement model and aero-elastic-vibration-measurement model of a large cooling tower are built.The stagnation point,peak suction point,separation point and leeward point of the throat position shell are selected to analyze pressure coefficient,probability distribution,peak factor,power spectral density and dynamic amplification factor under normal wind and typhoon.It is clarified that there exists a significant non-Gaussian characteristic under typhoon condition,which also exists in structural response level.Resonance response ratio of the total response is higher during typhoon condition.The maximum value of dynamic amplification coefficient under typhoon field is up to 1.18 times over that under normal wind.The findings of this study are expected to be of interest and practical use to professional and researchers involved in the wind-resistant designs of super-large cooling towers in typhoon prone regions. 展开更多
关键词 cooling towers active wind tunnel non-Gaussian characteristic wind-induced vibration dynamic amplification coefficient
在线阅读 下载PDF
Wind tunnel study on wind-induced vibration of middle pylon of Taizhou Bridge
8
作者 Ma Rujin Zhang Zhen Chen Airong 《Engineering Sciences》 EI 2012年第3期77-80,92,共5页
Full aero-elastic model tests are carried out to investigate wind-induced vibration of middle steel pylon of Taizhou Bridge. Model of the pylon under different construction periods is tested in both uniform and turbul... Full aero-elastic model tests are carried out to investigate wind-induced vibration of middle steel pylon of Taizhou Bridge. Model of the pylon under different construction periods is tested in both uniform and turbulent flow field. And the yaw angle of wind changes from transverse to longitudinal. Through full aero-elastic model testing, wind-induced vibration is checked, which includes vortex resonance, buffeting and galloping. Vortex resonance is observed and further studies are carried out by changing damping ratio. Based on wind tunnel testing results, wind-resistance of middle pylon is evaluated and some suggestions are given for middle pylon's construction. 展开更多
关键词 wind tunnel test aero-elastic modeL wind-induced vibration middle pylon
在线阅读 下载PDF
Effect of vibration at low frequency on the friction coefficient of Ti6AI4V alloy
9
《焊接技术》 北大核心 2011年第4期I0001-I0002,共2页
关键词 《焊接技术》 英文摘要 内容介绍 期刊
在线阅读 下载PDF
Wind-induced responses of super-large cooling towers 被引量:3
10
作者 柯世堂 葛耀君 +2 位作者 赵林 陈少林 Y.Tamura 《Journal of Central South University》 SCIE EI CAS 2013年第11期3216-3228,共13页
Traditional gust load factor(GLF)method,inertial wind load(IWL)method and tri-component method(LRC+IWL)cannot accurately analyze the wind-induced responses of super-large cooling towers,so the real combination formula... Traditional gust load factor(GLF)method,inertial wind load(IWL)method and tri-component method(LRC+IWL)cannot accurately analyze the wind-induced responses of super-large cooling towers,so the real combination formulas of fluctuating wind-induced responses and equivalent static wind loads(ESWLSs)were derived based on structural dynamics and random vibration theory.The consistent coupled method(CCM)was presented to compensate the coupled term between background and resonant response.Taking the super-large cooling tower(H=215 m)of nuclear power plant in Jiangxi Province,China,which is the highest and largest in China,as the example,based on modified equivalent beam-net design method,the aero-elastic model for simultaneous pressure and vibration measurement of super-large cooling tower is firstly carried out.Then,combining wind tunnel test and CCM,the effects of self-excited force on the surface pressures and wind-induced responses are discussed,and the wind-induced response characteristics of background component,resonant component,coupled term between background and resonant response,fluctuating responses,and wind vibration coefficients are discussed.It can be concluded that wind-induced response mechanism must be understood to direct the wind resistant design for super-large cooling towers. 展开更多
关键词 super-large cooling towers wind-induced responses wind vibration coefficients aero-elastic model consistent coupled method
在线阅读 下载PDF
Wind Vibration Study of Long-span Steel Arch Structure of Beijing Capital International Airport 被引量:4
11
作者 周岱 马俊 +1 位作者 朱忠义 柳杰 《Journal of Shanghai Jiaotong university(Science)》 EI 2005年第4期429-435,共7页
The wind-induced dynamic response of long-span light-weight steel arch structure of the global transportation center (GTC) of Beijing Capital International Airport was studied. A composite technique with combination o... The wind-induced dynamic response of long-span light-weight steel arch structure of the global transportation center (GTC) of Beijing Capital International Airport was studied. A composite technique with combination of WAWS(Weighted Amplitude Wavelet Superposition) and FFT(Fast Fourier Transformation) was introduced to simulate wind velocity time series of hundreds of spatial points simultaneously. The structural shape factors of wind load was obtained from wind tunnel model test. The wind vibration factor based on structural displacement response was investigated. After comparing the computational results with wind tunnel model test data, it was found out that the two results accord with each other if wind comes from 0° direction angle, but are quite different if wind comes from 180° direction angle in the area blocked off by airport terminals. The possible reasons of this difference were analyzed. Haar wavelet was used to transform and analyze wind velocity time series and structural wind-induced dynamic responses. The relationship between exciting wind loads and structural responses was studied in time and frequency domains. 展开更多
关键词 steel arch structure wind velocity time series wind-induced vibration factor wavelet analysis
在线阅读 下载PDF
TORSIONAL VIBRATIONS OF A RIGID CIRCULAR PLATE ON SATURATED STRATUM OVERLAYING BEDROCK 被引量:3
12
作者 CaiYuanqiang WuDazhi XuChangjie 《Acta Mechanica Solida Sinica》 SCIE EI 2005年第2期142-149,共8页
The torsional vibration of a rigid plate resting on saturated stratum overlaying bedrock has been analysed for the first time. The dynamic governing differential equations for saturated poroelastic medium are solved b... The torsional vibration of a rigid plate resting on saturated stratum overlaying bedrock has been analysed for the first time. The dynamic governing differential equations for saturated poroelastic medium are solved by employing the technology of Hankel transform. By taking into account the boundary conditions, the dual integral equations of torsional vibration of a rigid circular plate are established, which are further converted into a Fredholm integral equation of the second kind. Subsequently, the dynamic compliance coefficients of the foundation on saturated stratum, the contact shear stress under the foundation and the angular amplitude of the foundation are evaluated. Numerical results indicate that, when the dimensionless height is bigger than 5, saturated stratum overlaying bedrock can be treated as saturated half space approximately. When the dimensionless frequency is low, the permeability of the soil must be taken into account. Furthermore, when the vibration frequency is a constant, the height of the saturated stratum has a slight effect on the dimensionless contact shear stress under the foundation. 展开更多
关键词 saturated stratum overlaying bedrock torsional vibration rigid circular plate dynamical compliance coefficients contact shear stress
在线阅读 下载PDF
Hydrodynamics of A Flexible Riser Undergoing the Vortex-Induced Vibration at High Reynolds Number 被引量:1
13
作者 REN Tie ZHANG Meng-meng +1 位作者 FU Shi-xiao SONG Lei-jian 《China Ocean Engineering》 SCIE EI CSCD 2018年第5期570-581,共12页
This study proposed a method to obtain hydrodynamic forces and coefficients for a flexible riser undergoing the vortex-induced vibration(VIV), based on the measured strains collected from the scale-model testing with ... This study proposed a method to obtain hydrodynamic forces and coefficients for a flexible riser undergoing the vortex-induced vibration(VIV), based on the measured strains collected from the scale-model testing with the Reynolds numbers ranging from 1.34 E5 to 2.35 E5. The riser is approximated as a tensioned spatial beam, and an inverse method based on the FEM of spatial beam is adopted for the calculation of hydrodynamic forces in the cross flow(CF) and inline(IL) directions. The drag coefficients and vortex-induced force coefficients are obtained through the Fourier Series Theory. Finally, the hydrodynamic characteristics of a flexible riser model undergoing the VIV in a uniform flow are carefully investigated. The results indicate that the VIV amplifies the drag coefficient, and the drag coefficient does not change with time when the CF VIV is stable. Only when the VIVs in the CF and IL directions are all steady vibrations, the vortex-induced force coefficients keep as a constant with time, and under"lock-in" condition, whether the added-mass coefficient changes with time or not, the oscillation frequency of the VIV keeps unchanged. It further shows that the CF excitation coefficients at high frequency are much smaller than those at the dominant frequency, while, the IL excitation coefficients are in the same range. The axial distributions of the excitation and damping region at the dominant frequency and high frequency are approximately consistent in the CF direction, while, in the IL direction, there exists a great difference. 展开更多
关键词 flexible riser vortex-induced vibration vortex-induced force excitation coefficient added-mass coefficient drag coefficient
在线阅读 下载PDF
ACTIVE VIBRATION CONTROL OF TWO-BEAM STRUCTURES 被引量:1
14
作者 陈涛 王立刚 冯国锋 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 2013年第2期193-201,共9页
The wave propagation approach is presented to research the active vibration control of two-beam structures.Considering the continuity of the generalized displacement and the equilibrium of the generalized force at the... The wave propagation approach is presented to research the active vibration control of two-beam structures.Considering the continuity of the generalized displacement and the equilibrium of the generalized force at the discontinuity,the wave reflection and transmission coefficients are calculated.Wave control is applied somewhere upstream or downstream to two-beam structures.Vibrations of two coupled beams per unit disturbance are investigated.The results show that wave control is efficient,and the influence of the thickness ratio of two-beam structures on control location is discussed. 展开更多
关键词 two-beam STRUCTURES vibration CONTROL REFLECTION coefficientS TRANSMISSION coefficientS
在线阅读 下载PDF
Passive Perforated Pipe Control Method for Wind?Induced Vibration of a High?Rise Chemical Tower 被引量:2
15
作者 LU Shanshan ZHANG Zhifu +1 位作者 ZHANG Runtao CHEN Wenli 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI CSCD 2020年第1期99-107,共9页
Vortex-induced vibration is likely to occur when subjected to wind loads because of low horizontal stiffness,resulting in internal force and large lateral amplitude.Long-term wind-induced vibration can not only affect... Vortex-induced vibration is likely to occur when subjected to wind loads because of low horizontal stiffness,resulting in internal force and large lateral amplitude.Long-term wind-induced vibration can not only affect the normal service and durability performance of chemical towers,but also seriously endanger the safety of towers in service periods,and cause property losses.In this study,a passive control method for suppressing wind-induced vibration of chemical towers is proposed.The flow around the flow field is guided by a pre-set air-blowing channel,thus destroying the unsteady vortex shedding in the wake region of the flow field and achieving the purpose of flow control.Two accelerometers are used to measure the vibration signal of the chemical tower model with and without the perforated pipe.The control effects of the spacing and the installation position of the perforated pipe are then studied.Experimental results show that the passive perforated pipe control method can effectively reduce the vibration amplitude of the chemical tower under wind loads,and decrease the potential wind-induced vibration. 展开更多
关键词 chemical tower wind-induced vibration pneumatic control
在线阅读 下载PDF
A Correlation Coefficient Approach for Evaluation of Stiffness Degradation of Beams Under Moving Load 被引量:2
16
作者 Thanh Q.Nguyen Thao T.D.Nguyen +1 位作者 H.Nguyen-Xuan Nhi K.Ngo 《Computers, Materials & Continua》 SCIE EI 2019年第7期27-53,共27页
This paper presents a new approach using correlation and cross-correlation coefficients to evaluate the stiffness degradation of beams under moving load.The theoretical study of identifying defects by vibration method... This paper presents a new approach using correlation and cross-correlation coefficients to evaluate the stiffness degradation of beams under moving load.The theoretical study of identifying defects by vibration methods showed that the traditional methods derived from the vibration measurement data have not met the needs of the actual issues.We show that the correlation coefficients allow us to evaluate the degree and the effectiveness of the defects on beams.At the same time,the cross-correlation model is the basis for determining the relative position of defects.The results of this study are experimentally conducted to confirm the relationship between the correlation coefficients and the existence of the defects.In particular,the manuscript shows that the sensitivity of the correlation coefficients and cross-correlation is much higher than the parameters such as changes in stiffness(EJ)and natural frequency values(Δf).This study suggests using the above parameters to evaluate the stiffness degradation of beams by vibration measurement data in practice. 展开更多
关键词 Correlation coefficient CROSS-CORRELATION vibration signal vibration amplitude FREQUENCY
在线阅读 下载PDF
Wind-induced response analysis of conical membrane structures 被引量:2
17
作者 陈波 武岳 沈世钊 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2005年第5期481-487,共7页
Conical membrane structures are a typical form of tensile membrane structures. In the past, most studies focused on the static performance, but few on dynamic performance. In this paper, systematic parameter analysis ... Conical membrane structures are a typical form of tensile membrane structures. In the past, most studies focused on the static performance, but few on dynamic performance. In this paper, systematic parameter analysis of wind-induced response of conical membrane structures has been performed with nonlinear random simulation method in a time domain, by considering some parameters, such as span, rise-span ratio, prestress of membrane, and characteristic of the approaching wind flow. Moreover, formulas of the dynamic coefficient and nonlinear adjustment factor are advised, which can be conveniently used in wind-resistant design of conical membrane structures. 展开更多
关键词 conical membrane structures wind-induced response the dynamic coefficient nonlinear adjustment factor
在线阅读 下载PDF
Impact coefficient and reliability of mid-span continuous beam bridge under action of extra heavy vehicle with low speed 被引量:12
18
作者 刘波 王有志 +1 位作者 胡朋 袁泉 《Journal of Central South University》 SCIE EI CAS CSCD 2015年第4期1510-1520,共11页
To analyze the dynamic response and reliability of a continuous beam bridge under the action of an extra heavy vehicle, a vehicle–bridge coupled vibration model was established based on the virtual work principle and... To analyze the dynamic response and reliability of a continuous beam bridge under the action of an extra heavy vehicle, a vehicle–bridge coupled vibration model was established based on the virtual work principle and vehicle–bridge displacement compatibility equation, which can accurately simulate the dynamic characteristics of the vehicle and bridge. Results show that deck roughness has an important function in the effect of the vehicle on the bridge. When an extra heavy vehicle passes through the continuous beam bridge at a low speed of 5 km/h, the impact coefficient reaches a high value, which should not be disregarded in bridge safety assessments. Considering that no specific law exists between the impact coefficient and vehicle speed, vehicle speed should not be unduly limited and deck roughness repairing should be paid considerable attention. Deck roughness has a significant influence on the reliability index, which decreases as deck roughness increases. For the continuous beam bridge in this work, the reliability index of each control section is greater than the minimum reliability index. No reinforcement measures are required for over-sized transport. 展开更多
关键词 continuous beam bridge extra heavy vehicle coupled vibration impact coefficient reliability
在线阅读 下载PDF
Humidification vibration deformation behavior of intact loess 被引量:1
19
作者 CHENG Da-wei LUO Ya-sheng +2 位作者 WU Cai-ping CHEN Xi GUO Hong 《Journal of Central South University》 SCIE EI CAS 2013年第7期1985-1991,共7页
A parameter, known as the parameter of humidification vibration deformation, was proposed, describing quantitatively the impact of water content on vibration settlement deformation, and its relationship with humidific... A parameter, known as the parameter of humidification vibration deformation, was proposed, describing quantitatively the impact of water content on vibration settlement deformation, and its relationship with humidification water content, dynamic shear stress peak value, initial consolidation stress and vibration frequency was built. The result shows that 1) the parameter of humidification vibration deformation increases with the vibration shear stress peak value increasing. 2) The humidification water content has significant influence on the curve of the parameter of humidification vibration deformation and the peak vibration shear stress. When the humidification water content is low, the curve increases slowly. However, when the humidification water content is high, the curve increases rapidly. 3) Initial consolidation stress has significant influence on the humidification vibration deformation coefficient. When initial consolidation stress is not large enough to destroy the loess structure, with initial consolidation stress increasing, the humidification vibration deformation coefficient decreases. On the contrary, the humidification vibration deformation coefficient increases with initial consolidation stress increasing. 4) With the increase of vibration time, the parameter of humidification vibration settlement shows an increasing trend overall. The initial dynamic shear stress peak value and humidification water content all have significant effects on the curve of the parameter of humidification vibration settlement and vibration time. However, the humidification water content is even more significant. 展开更多
关键词 intact loess vibration deformation humidification vibration deformation coefficient
在线阅读 下载PDF
Application of Lead Viscoelastic Dampers to Wind Vibration Control on Big-Span Power Transmission Tower 被引量:1
20
作者 梁政平 李黎 +1 位作者 尹鹏 段松涛 《Journal of Southwest Jiaotong University(English Edition)》 2008年第4期320-328,共9页
To study the wind vibration response of power transmission tower, the lead viscoelastic dampers (LVDs) were applied to a cup tower. With time history analysis method, the displacement, velocity, acceleration and for... To study the wind vibration response of power transmission tower, the lead viscoelastic dampers (LVDs) were applied to a cup tower. With time history analysis method, the displacement, velocity, acceleration and force response of the tower was calculated and analyzed. The results show that the control effect of lead viscoelastic dampers is very good, and the damping ratio can reach 20% or more when they are applied to the tower head. 展开更多
关键词 Transmission tower Lead viscoelastic damper wind-induced vibration control
在线阅读 下载PDF
上一页 1 2 68 下一页 到第
使用帮助 返回顶部