Uncertainty is an essentially challenging for safe construction and long-term stability of geotechnical engineering.The inverse analysis is commonly utilized to determine the physico-mechanical parameters.However,conv...Uncertainty is an essentially challenging for safe construction and long-term stability of geotechnical engineering.The inverse analysis is commonly utilized to determine the physico-mechanical parameters.However,conventional inverse analysis cannot deal with uncertainty in geotechnical and geological systems.In this study,a framework was developed to evaluate and quantify uncertainty in inverse analysis based on the reduced-order model(ROM)and probabilistic programming.The ROM was utilized to capture the mechanical and deformation properties of surrounding rock mass in geomechanical problems.Probabilistic programming was employed to evaluate uncertainty during construction in geotechnical engineering.A circular tunnel was then used to illustrate the proposed framework using analytical and numerical solution.The results show that the geomechanical parameters and associated uncertainty can be properly obtained and the proposed framework can capture the mechanical behaviors under uncertainty.Then,a slope case was employed to demonstrate the performance of the developed framework.The results prove that the proposed framework provides a scientific,feasible,and effective tool to characterize the properties and physical mechanism of geomaterials under uncertainty in geotechnical engineering problems.展开更多
In this paper,a dynamic modeling method of motor driven electromechanical system is presented,and the uncertainty quantification of mechanism motion is investigated based on this method.The main contribution is to pro...In this paper,a dynamic modeling method of motor driven electromechanical system is presented,and the uncertainty quantification of mechanism motion is investigated based on this method.The main contribution is to propose a novel mechanism-motor coupling dynamic modeling method,in which the relationship between mechanism motion and motor rotation is established according to the geometric coordination of the system.The advantages of this include establishing intuitive coupling between the mechanism and motor,facilitating the discussion for the influence of both mechanical and electrical parameters on the mechanism,and enabling dynamic simulation with controller to take the randomness of the electric load into account.Dynamic simulation considering feedback control of ammunition delivery system is carried out,and the feasibility of the model is verified experimentally.Based on probability density evolution theory,we comprehensively discuss the effects of system parameters on mechanism motion from the perspective of uncertainty quantization.Our work can not only provide guidance for engineering design of ammunition delivery mechanism,but also provide theoretical support for modeling and uncertainty quantification research of mechatronics system.展开更多
3D printing is widely adopted to quickly produce rock mass models with complex structures in batches,improving the consistency and repeatability of physical modeling.It is necessary to regulate the mechanical properti...3D printing is widely adopted to quickly produce rock mass models with complex structures in batches,improving the consistency and repeatability of physical modeling.It is necessary to regulate the mechanical properties of 3D-printed specimens to make them proportionally similar to natural rocks.This study investigates mechanical properties of 3D-printed rock analogues prepared by furan resin-bonded silica sand particles.The mechanical property regulation of 3D-printed specimens is realized through quantifying its similarity to sandstone,so that analogous deformation characteristics and failure mode are acquired.Considering similarity conversion,uniaxial compressive strength,cohesion and stress–strain relationship curve of 3D-printed specimen are similar to those of sandstone.In the study ranges,the strength of 3D-printed specimen is positively correlated with the additive content,negatively correlated with the sand particle size,and first increases then decreases with the increase of curing temperature.The regulation scheme with optimal similarity quantification index,that is the sand type of 70/140,additive content of 2.5‰and curing temperature of 81.6℃,is determined for preparing 3D-printed sandstone analogues and models.The effectiveness of mechanical property regulation is proved through uniaxial compression contrast tests.This study provides a reference for preparing rock-like specimens and engineering models using 3D printing technology.展开更多
This paper proposed an efficient research method for high-dimensional uncertainty quantification of projectile motion in the barrel of a truck-mounted howitzer.Firstly,the dynamic model of projectile motion is establi...This paper proposed an efficient research method for high-dimensional uncertainty quantification of projectile motion in the barrel of a truck-mounted howitzer.Firstly,the dynamic model of projectile motion is established considering the flexible deformation of the barrel and the interaction between the projectile and the barrel.Subsequently,the accuracy of the dynamic model is verified based on the external ballistic projectile attitude test platform.Furthermore,the probability density evolution method(PDEM)is developed to high-dimensional uncertainty quantification of projectile motion.The engineering example highlights the results of the proposed method are consistent with the results obtained by the Monte Carlo Simulation(MCS).Finally,the influence of parameter uncertainty on the projectile disturbance at muzzle under different working conditions is analyzed.The results show that the disturbance of the pitch angular,pitch angular velocity and pitch angular of velocity decreases with the increase of launching angle,and the random parameter ranges of both the projectile and coupling model have similar influence on the disturbance of projectile angular motion at muzzle.展开更多
Artificial intelligence(AI),particularly machine learning(ML)and deep learning(DL)techniques,such as convolutional neural networks(CNNs),have emerged as transformative technologies with vast potential in healthcare.Bo...Artificial intelligence(AI),particularly machine learning(ML)and deep learning(DL)techniques,such as convolutional neural networks(CNNs),have emerged as transformative technologies with vast potential in healthcare.Body iron load is usually assessed using slightly invasive blood tests(serum ferritin,serum iron,and serum transferrin).Serum ferritin is widely used to assess body iron and drive medical management;however,it is an acute phase reactant protein offering wrong interpretation in the setting of inflammation and distressed patients.Magnetic resonance imaging is a non-invasive technique that can be used to assess liver iron.The ML and DL algorithms can be used to enhance the detection of minor changes.However,a lack of open-access datasets may delay the advancement of medical research in this field.In this letter,we highlight the importance of standardized datasets for advancing AI and CNNs in medical imaging.Despite the current limitations,embracing AI and CNNs holds promise in revolutionizing disease diagnosis and treatment.展开更多
Short-chain fatty acids (SCFA) play an important role in human biochemistry. They originate primarily from the digestive system through carbohydrates microbial fermentation. Most SCFA produced in the colon are absorbe...Short-chain fatty acids (SCFA) play an important role in human biochemistry. They originate primarily from the digestive system through carbohydrates microbial fermentation. Most SCFA produced in the colon are absorbed by the intestinal wall and enter the bloodstream to be distributed throughout the body for multiple purposes. At the intestinal level, SCFA play a role in controlling fat storage and fatty acid metabolism. The effects of these beneficial compounds therefore concern overall health. They facilitate energy expenditure and are valuable allies in the fight against obesity and diabetes. SCFA are also involved in the regulation of the levels of several neurotransmitters such as GABA (γ-aminobutyric acid), glutamate, serotonin, dopamine, and norepinephrine. Their role is also highlighted in many inflammatory and neurodegenerative diseases such as Alzheimer’s disease (AD) or Parkinson’s disease (PD). To have a realistic picture of the distribution of SCFA in different biological compartments of the human body, we propose to study SCFA simultaneously in five human biological samples: feces, saliva, serum, cerebrospinal fluid (CSF), and urine, as well as in Dried Blood Spot (DBS). To evaluate their concentration and repeatability, we used 10 aliquots from pooled samples, analyzed by 3-nitrophenylhydrazine (3-NPH) derivation and liquid chromatography coupled with high sensitivity mass spectrometry (LC-QqQ-MS). We also evaluated the SCFA assay on Dried Blood Spot (DBS). In this work, we adapted the pre-analytical parts for each sample to be able to use a common calibration curve, thus facilitating multi-assay quantification studies and so being less time-consuming. Moreover, we proposed new daughter ions from the same neutral loss (43 Da) to quantify SCFAs, thus improving the sensitivity. In conclusion, our methodology, based on a unique calibration curve for all samples for each SCFA, is well-suited to quantified them in a clinical context.展开更多
Real-time PCR is a closed DNA amplification system that skillfully integrates biochemical, photoelectric and computer techniques. Fluorescence data acquired once per cycle provides rapid absolute quantification of ini...Real-time PCR is a closed DNA amplification system that skillfully integrates biochemical, photoelectric and computer techniques. Fluorescence data acquired once per cycle provides rapid absolute quantification of initial template copy numbers as PCR products are generated. This technique significantly simplifies and accelerates the process of producing reproducible quantification of nucleic acid molecules. It not only is a sensitive, accurate and rapid quantitative method, but it also provides an easier way to calculate the absolute starting copy number of nucleic acid molecules to be tested. Together with molecular bio-techniques, like microarray, real-time PCR will play a very important role in many aspects of molecular life science such as functional gene analysis and disease molecular diagnostics. This review introduces the detailed principles and application of the real-time PCR technique, describes a recently developed system for exact quantification of AUX/IAA genes In Arabidopsis, and discusses the problems with the real-time PCR process.展开更多
AIM To investigate and compare the analytical and clinical performance of Tian Long automatic hypersensitive hepatitis B virus(HBV) DNA quantification system and Roche CAP/CTM system.METHODS Two hundred blood samples ...AIM To investigate and compare the analytical and clinical performance of Tian Long automatic hypersensitive hepatitis B virus(HBV) DNA quantification system and Roche CAP/CTM system.METHODS Two hundred blood samples for HBV DNA testing, HBV-DNA negative samples and high-titer HBV-DNA mixture samples were collected and prepared. National standard materials for serum HBV and a worldwide HBV DNA panel were employed for performance verification. The analytical performance, such as limit of detection, limit of quantification, accuracy, precision, reproducibility, linearity, genotype coverage and cross-contamination, was determined using the Tian Long automatic hypersensitive HBV DNA quantification system(TL system). Correlation and Bland-Altman plot analyses were carried out to compare the clinical performance of the TL system assay and the CAP/CTM system. RESULTS The detection limit of the TL system was 10 IU/m L, and its limit of quantification was 30 IU/m L. The differences between the expected and tested concentrations of the national standards were less than ± 0.4 Log10 IU/m L, which showed high accuracy of the system. Results of the precision, reproducibility and linearity tests showed that the multiple test coefficient of variation(CV) of the same sample was less than 5% for 102-106 IU/m L; and for 30-108 IU/m L, the linear correlation coefficient r2 = 0.99. The TL system detected HBV DNA(A-H) genotypes and there was no cross-contamination during the "checkerboard" test. When compared with the CAP/CTM assay, the two assays showed 100% consistency in both negative and positive sample results(15 negative samples and 185 positive samples). No statistical differences between the two assays in the HBV DNA quantification values were observed(P > 0.05). Correlation analysis indicated a significant correlation between the two assays, r2 = 0.9774. The Bland-Altman plot analysis showed that 98.9% of the positive data were within the 95% acceptable range, and the maximum difference was-0.49.CONCLUSION The TL system has good analytical performance, and exhibits good agreement with the CAP/CTM system in clinical performance.展开更多
AIM:To investigate precore/basal core promoter(PC/BCP) mutants throughout hepatitis B virus(HBV) infection and to determine their relationship to hepatitis B early antigen(HBeA g) titers.METHODS:We enrolled 191 patien...AIM:To investigate precore/basal core promoter(PC/BCP) mutants throughout hepatitis B virus(HBV) infection and to determine their relationship to hepatitis B early antigen(HBeA g) titers.METHODS:We enrolled 191 patients in various stages of HBV infection at the Huashan Hospital and the Taizhou Municipal Hospital from 2010 to 2012.None of the patients received antiviral therapy.HBV DNA from serum,was quantified by real-time PCR.The HBV genotype was determined by direct sequencing of the S gene.We used the Simpleprobe ultrasensitivequantitative method to detect PC/BCP mutants in each patient.We compared the strain number,percentage,and the changes in PC/BCP mutants in different phases,and analyzed the relationship between PC/BCP mutants and HBe Ag by multiple linear regression and logistic regression.RESULTS:Patients with HBV infection(n = 191) were assigned to groups by phase:Immune tolerance(IT) = 55,Immune clearance(IC) = 67,Low-replicative(LR) = 49,and HBeA g-negative hepatitis(ENH) = 20.Of the patients(male,112; female,79) enrolled,122 were HBe Ag-positive and 69 were HBe Ag-negative.The median age was 33 years(range:18-78 years).PC and BCP mutation detection rates were 84.82%(162/191) and 96.86%(185/191),respectively.In five HBe Ag-negative cases,we detected double mutation G1896A/G1899 A.The logarithm value of PC mutant quantities(log10 PC) significantly differed in IT,IC,and LR phases,as well as in the ENH phase(F = 49.350,P < 0.001).The logarithm value of BCP mutant quantities(log10 BCP) also differed during the four phases(F = 25.530,P < 0.001).Log10 PC and log10 BCP values were high in the IT and IC phases,decreased in the LR phase,and increased in the ENH phase,although the absolute value at this point remained lower than that in the IT and IC phases.PC mutant quantity per total viral load(PC%) and BCP mutant quantity per total viral load(BCP%) differed between phases(F = 20.040,P < 0.001; F = 10.830,P < 0.001),with PC% and BCP% gradually increasing in successive phases.HBeA g titers negatively correlated with PC%(Spearman's rho =-0.354,P < 0.001) and BCP%(Spearman's rho =-0.395,P < 0.001).The negative correlation between PC% and HBeA g status was significant(B =-5.281,P = 0.001),but there was no such correlation between BCP% and HBeA g status(B =-0.523,P = 0.552).CONCLUSION:PC/BCP mutants become predominant in a dynamic and continuous process.Log10 PC,log10 BCP,PC% and BCP% might be combined to evaluate disease progression.PC% determines HBeA g status.展开更多
This paper reviews recent research on the demand flexibility of residential buildings in regard to definitions,flexible loads,and quantification methods.A systematic distinction of the terminology is made,including th...This paper reviews recent research on the demand flexibility of residential buildings in regard to definitions,flexible loads,and quantification methods.A systematic distinction of the terminology is made,including the demand flexibility,operation flexibility,and energy flexibility of buildings.A comprehensive definition of building demand flexibility is proposed based on an analysis of the existing definitions.Moreover,the flexibility capabilities and operation characteristics of the main residential flexible loads are summarized and compared.Models and evaluation indicators to quantify the flexibility of these flexible loads are reviewed and summarized.Current research gaps and challenges are identified and analyzed as well.The results indicate that previous studies have focused on the flexibility of central air conditioning,electric water heaters,wet appliances,refrigerators,and lighting,where the proportion of studies focusing on each of these subjects is 36.7%,25.7%,14.7%,9.2%,and 8.3%,respectively.These flexible loads are different in running modes,usage frequencies,seasons,and capabilities for shedding,shifting,and modulation,while their response characteristics are not yet clear.Furthermore,recommendations are given for the application of white-,black-,and grey-box models for modeling flexible loads in different situations.Numerous static flexibility evaluation indicators that are based on the aspects of power,temporality,energy,efficiency,economics,and the environment have been proposed in previous publications,but a consensus and standardized evaluation framework is lacking.This review can help readers better understand building demand flexibility and learn about the characteristics of different residential flexible loads,while also providing suggestions for future research on the modeling techniques and evaluation metrics of residential building demand flexibility.展开更多
To establish a rapid quantification method for heparinase I during its production in recombinant Escherichia coli, a translational fusion vector was constructed by fusing the N terminus of heparinase I to the C termin...To establish a rapid quantification method for heparinase I during its production in recombinant Escherichia coli, a translational fusion vector was constructed by fusing the N terminus of heparinase I to the C terminus of a green fluorescent protein mutant (GFPmutl). As a result, not only was the functional recombinant expression of heparinase I in E. coli accomplished, but also a linear correlation was obtained between the GFP fluorescence intensity and heparinase I activity, allowing enzyme activity to be quantified rapidly during the fermentation.展开更多
AIM: To evaluate the feasibility of quantifying liver choline concentrations in both normal and apoptotic rabbit livers in vivo, using 1H magnetic resonance spectroscopy (1H-MRS). METHODS: 1H-MRS was performed in 18 r...AIM: To evaluate the feasibility of quantifying liver choline concentrations in both normal and apoptotic rabbit livers in vivo, using 1H magnetic resonance spectroscopy (1H-MRS). METHODS: 1H-MRS was performed in 18 rabbits using a 1.5T GE MR system with an eight-channel head/neck receiving coil. Fifteen rabbits were injected with sodium selenite at a dose of 10 μmol/kg to induce the liver cell apoptosis. Point-resolved spectroscopy sequencelocalized spectra were obtained from 10 livers once before and once 24 h after sodium selenite injection in vivo. T1 and T2 relaxation time of water and choline was measured separately in the livers of three healthy rabbits and three selenite-treated rabbits. Hematoxylin and eosin and dUTP-biotin nick end labeling (TUNEL) staining was used to detect and confirm apoptosis. Choline peak areas were measured relative to unsuppressed water using LCModel. Relaxation attenuation was corrected using the average of T1 and T2 relaxation time. The choline concentration was quantified using a formula, which was tested by a phantom with a known concentration. RESULTS: Apoptosis of hepatic cells was confirmed by TUNEL assay. In phantom experiment, the choline concentration (3.01 mmol/L), measured by 1H-MRS, was in good agreement with the actual concentration (3 mmol/L). The average T1 and T2 relaxation time of choline was 612 ± 15 ms and 74 ± 4 ms in the control group and 670 ± 27 ms and 78 ± 5 ms in apoptotic livers in vivo, respectively. Choline was quantified in 10 rabbits, once before and once after the injection with sodium selenite. The choline concentration decreased from 14.5 ± 7.57 mmol/L before sodium selenite injection to 10.8 ± 6.58 mmol/L (mean ± SD, n = 10) after treatment (Z = -2.395, P < 0.05, two-sample paired Wilcoxon test). CONCLUSION: 1H-MRS can be used to quantify liver choline in vivo using unsuppressed water as an internal reference. Decreased liver choline concentrations are found in sodium selenite-treated rabbits undergoing liver cell apoptosis.展开更多
BACKGROUND Diabetic kidney disease(DKD)is a common complication of diabetes.The patient’s prognosis is poor once DKD progresses to advanced stage.Accurate diagnosis and timely treatment of early DKD are important for...BACKGROUND Diabetic kidney disease(DKD)is a common complication of diabetes.The patient’s prognosis is poor once DKD progresses to advanced stage.Accurate diagnosis and timely treatment of early DKD are important for improving patient’s prognosis and reducing mortality.AIM To explore the value of elastography point quantification(ElastPQ)in improving the accuracy of early DKD diagnosis.METHODS A total of 69 patients with type 2 diabetes were recruited from Naval Military Medical University Affiliated Gongli Hospital.Patients were divided into early DKD group and medium DKD group according to pathological results and urinary albumin excretion rate(UAER).Another 40 patients with simple diabetes were included as the diabetes group.The baseline data,laboratory diagnostic indicators,and ultrasound indicators for each patient were recorded.The differences of the indicators in the three groups were compared.Multivariate logistic regression was used to analyze the influencing factors of the development from simple diabetes into early DKD and from early DKD into medium DKD.Receiver operating characteristic analyses of potential indicators in identifying early DKD and medium DKD,and early DKD and simple diabetes were established.RESULTS Multivariate logistic regression analysis showed that UAER(P<0.001),renocortical Young's Modulus(YM)(P<0.001),and renal parenchymal thickness(P=0.013)were the independent influencing factors of the development from early DKD into medium DKD.Diabetes duration(P=0.041),UAER(P=0.034),and renocortical YM(P=0.017)were the independent influencing factors of the development from simple diabetes into early DKD.Receiver operating characteristic analysis indicated that UAER,renocortical YM,and renal parenchymal thickness were accurate in identifying early DKD and medium DKD[all area under curve(AUC)>0.9].The accuracy of UAER(AUC=0.744),diabetes duration(AUC=0.757),and renocortical YM(AUC=0.782)for the diagnosis of early DKD and simple diabetes were limited.However,the combined diagnosis of UAER,diabetes duration,and renocortical YM was accurate in identifying early DKD and simple diabetes(AUC=0.906),which was significantly higher than any of the three indicators(all P<0.05).CONCLUSION ElastPQ is of great value in the diagnosis of early DKD.When combined with the diabetes duration and UAER,it is expected to diagnose accurately early DKD.展开更多
As an alternative or complementary approach to the classical probability theory,the ability of the evidence theory in uncertainty quantification(UQ) analyses is subject of intense research in recent years.Two state-...As an alternative or complementary approach to the classical probability theory,the ability of the evidence theory in uncertainty quantification(UQ) analyses is subject of intense research in recent years.Two state-of-the-art numerical methods,the vertex method and the sampling method,are commonly used to calculate the resulting uncertainty based on the evidence theory.The vertex method is very effective for the monotonous system,but not for the non-monotonous one due to its high computational errors.The sampling method is applicable for both systems.But it always requires a high computational cost in UQ analyses,which makes it inefficient in most complex engineering systems.In this work,a computational intelligence approach is developed to reduce the computational cost and improve the practical utility of the evidence theory in UQ analyses.The method is demonstrated on two challenging problems proposed by Sandia National Laboratory.Simulation results show that the computational efficiency of the proposed method outperforms both the vertex method and the sampling method without decreasing the degree of accuracy.Especially,when the numbers of uncertain parameters and focal elements are large,and the system model is non-monotonic,the computational cost is five times less than that of the sampling method.展开更多
The influence of alkali on astaxanthin and the optimal working wave length for measurement of astaxanthin from Haematocoecus crude extract were investigated, and a spectrophotometric method for precise quantification ...The influence of alkali on astaxanthin and the optimal working wave length for measurement of astaxanthin from Haematocoecus crude extract were investigated, and a spectrophotometric method for precise quantification of the astaxanthin based on the method of Boussiba et al. was established. According to Boussiba's method, alkali treatment destroys chlorophyll. However, we found that: 1) carotenoid content declined for about 25% in Haematococcus fresh cysts and up to 30% in dry powder of Haematococcus broken cysts after alkali treatment; and 2) dimethyl sulfoxide (DMSO)-extracted chlorophyll of green Haematococeus bares little absorption at 520-550 nm. Interestingly, a good linear relationship existed between absorbance at 530 nm and astaxanthin content, while an unknown interference at 540-550 nm was detected in our study. Therefore, with 530 nm as working wavelength, the alkali treatment to destroy chlorophyll was not necessary and the influence of chlorophyll, other carotenoids, and the unknown interference could be avoided. The astaxanthin contents of two samples were measured at 492 nm and 530 nm; the measured values at 530 nm were 2.617 g/100 g and 1.811 g/100 g. When compared with the measured values at 492 nm, the measured values at 530 nm decreased by 6.93% and 11.96%, respectively. The measured values at 530 nm are closer to the true astaxanthin contents in the samples. The data show that 530 nm is the most suitable wave length for spectrophotometric determination to the astaxanthin in Haematococcus crude extract.展开更多
Hundreds of mine flooding accidents have occurred in China since the 1950s. These flooding accidents result in submerged working faces, even entire coal mines, leading to tremendous economic losses. It is reported tha...Hundreds of mine flooding accidents have occurred in China since the 1950s. These flooding accidents result in submerged working faces, even entire coal mines, leading to tremendous economic losses. It is reported that among 601 state-owned mines in China, 285 mines are exposed to water-inrush risks. The water pressure is becoming larger and larger with the increase of mining depth, leading to an increase of water-inrush hazards. Only when the risk of mine flooding is predicted in a reasonable manner, can we take timely and effective measures to prevent mine flooding from taking place. In our investigation quantification(H) theory is used to study the risk prediction problem about mine flooding. By investigating the main factors which affect mine flooding, eight risk assessment items have been identified. The extent of risk is classified into 4 grades. Given the data from different periods in the Feicheng mining area, a prediction model for the risk of mine flooding is established. The test analysis indicates a model correlation coefficient of 0.97 and the incidence of discrimination is as high as 97.37%, which implies that the effect of the model is quite satisfactory. With the help of computers, this method can be widely applied.展开更多
Green fluorescent protein (GFP) and its variants /homolog proteins are generally called as GFP-like fluorescent proteins (FPs), which are widely used as visible molecular tools for monitoring a wide range of biologica...Green fluorescent protein (GFP) and its variants /homolog proteins are generally called as GFP-like fluorescent proteins (FPs), which are widely used as visible molecular tools for monitoring a wide range of biological processes due to their capability of simple, accurate and real time quantification. The FPs-based molecular and visible quantification tools are giving more impact on bioprocess engineering, enabling the biomolecule-level dynamic information to be linked with the process-level events. In this review, different applications of FPs in biological engineering with emphasis on rapid molecular bioprocess quantification, such as quantification of the transcription efficiency, the protein production, the protein folding efficiency, the cell concentration, the intracellular microenvironments and so on, would be first introduced. The challenges of using FPs with respect to actual bioprocess applications for the precise quantification including the interaction of FPs and the fused partner proteins, the maturation of FPs, the inner filter effect and sensing technology were then discussed. Finally, the future development for the FPs used in molecular bioprocess quantification would be proposed.展开更多
A simple and accurate high-performance liquid chromatography(HPLC)coupled with diode array detector(DAD)and evaporative light scattering detector(ELSD)was established for the determination of six bioactive compo...A simple and accurate high-performance liquid chromatography(HPLC)coupled with diode array detector(DAD)and evaporative light scattering detector(ELSD)was established for the determination of six bioactive compounds in Zhenqi Fuzheng preparation(ZFP).The monitoring wavelengths were 254,275 and 328 nm.Under the optimum conditions,good separation was achieved,and the assay was fully validated in respect of precision,repeatability and accuracy.The proposed method was successfully applied to quantify the six ingredients in 31 batches of ZFP samples and evaluate the variation by hierarchical cluster analysis(HCA),which demonstrated significant variations on the content of these compounds in the samples from different manufacturers with different preparation procedures.The developed HPLC method can be used as a valid analytical method to evaluate the intrinsic quality of this preparation.展开更多
The quantificational and normative design is the precondition of improving the design of copper staves for blast furnaces. Based on a 3-dimensional temperature field calculation model, from the view point of heat tran...The quantificational and normative design is the precondition of improving the design of copper staves for blast furnaces. Based on a 3-dimensional temperature field calculation model, from the view point of heat transfer and long campaigns note with the core of forming accretion, the forming-accretion-ability (FAA) and the rib hot surface maximum temperature difference (ATmax) as quantificational indexes to direct and evaluate the design of copper staves for blast furnaces were presented. The application of the two indexes in design essentially embodies the new long campaigns in the stage of design. With the application of the two indexes, good results can be obtained. Firstly, it was suggested that the rib height of a copper stave can be reduced to 15 mm, which is a new method and theory for the reduction of copper staves. Secondly, the influence of insert on FAA and ATmax, is decided by the volume of insert. According to this, the principle of design for the hot surface geometry of copper staves was put forward that the ratio of the rib hot surface to the copper stave hot surface (abbreviated as the ratio of rib to stave) must be maintained in the range of 45% to 55%; for the present copper stave with a 35-40 mm thick rib, the ratio of rib to stave in the range of 50% to 55% can optimize the design of copper staves; for the copper stave with a smaller rib thickness, for example 15 ram, the ratio of rib to stave in the range of 45% to 50% can optimize the design of copper staves. It can be summarized that the thicker the rib thickness, the larger is the ratio of rib to stave. 2008 University of Science and Technology Beijing. All rights reserved.展开更多
基金The authors gratefully acknowledge the support from the National Natural Science Foundation of China(Grant No.42377174)the Natural Science Foundation of Shandong Province,China(Grant No.ZR2022ME198)the Open Research Fund of State Key Laboratory of Geomechanics and Geotechnical Engineering,Institute of Rock and Soil Mechanics,Chinese Academy of Sciences(Grant No.Z020006).
文摘Uncertainty is an essentially challenging for safe construction and long-term stability of geotechnical engineering.The inverse analysis is commonly utilized to determine the physico-mechanical parameters.However,conventional inverse analysis cannot deal with uncertainty in geotechnical and geological systems.In this study,a framework was developed to evaluate and quantify uncertainty in inverse analysis based on the reduced-order model(ROM)and probabilistic programming.The ROM was utilized to capture the mechanical and deformation properties of surrounding rock mass in geomechanical problems.Probabilistic programming was employed to evaluate uncertainty during construction in geotechnical engineering.A circular tunnel was then used to illustrate the proposed framework using analytical and numerical solution.The results show that the geomechanical parameters and associated uncertainty can be properly obtained and the proposed framework can capture the mechanical behaviors under uncertainty.Then,a slope case was employed to demonstrate the performance of the developed framework.The results prove that the proposed framework provides a scientific,feasible,and effective tool to characterize the properties and physical mechanism of geomaterials under uncertainty in geotechnical engineering problems.
基金supported by the National Natural Science Foundation of China(Grant Nos.11472137 and U2141246)。
文摘In this paper,a dynamic modeling method of motor driven electromechanical system is presented,and the uncertainty quantification of mechanism motion is investigated based on this method.The main contribution is to propose a novel mechanism-motor coupling dynamic modeling method,in which the relationship between mechanism motion and motor rotation is established according to the geometric coordination of the system.The advantages of this include establishing intuitive coupling between the mechanism and motor,facilitating the discussion for the influence of both mechanical and electrical parameters on the mechanism,and enabling dynamic simulation with controller to take the randomness of the electric load into account.Dynamic simulation considering feedback control of ammunition delivery system is carried out,and the feasibility of the model is verified experimentally.Based on probability density evolution theory,we comprehensively discuss the effects of system parameters on mechanism motion from the perspective of uncertainty quantization.Our work can not only provide guidance for engineering design of ammunition delivery mechanism,but also provide theoretical support for modeling and uncertainty quantification research of mechatronics system.
基金the National Natural Science Foundation of China(Nos.51988101 and 42007262).
文摘3D printing is widely adopted to quickly produce rock mass models with complex structures in batches,improving the consistency and repeatability of physical modeling.It is necessary to regulate the mechanical properties of 3D-printed specimens to make them proportionally similar to natural rocks.This study investigates mechanical properties of 3D-printed rock analogues prepared by furan resin-bonded silica sand particles.The mechanical property regulation of 3D-printed specimens is realized through quantifying its similarity to sandstone,so that analogous deformation characteristics and failure mode are acquired.Considering similarity conversion,uniaxial compressive strength,cohesion and stress–strain relationship curve of 3D-printed specimen are similar to those of sandstone.In the study ranges,the strength of 3D-printed specimen is positively correlated with the additive content,negatively correlated with the sand particle size,and first increases then decreases with the increase of curing temperature.The regulation scheme with optimal similarity quantification index,that is the sand type of 70/140,additive content of 2.5‰and curing temperature of 81.6℃,is determined for preparing 3D-printed sandstone analogues and models.The effectiveness of mechanical property regulation is proved through uniaxial compression contrast tests.This study provides a reference for preparing rock-like specimens and engineering models using 3D printing technology.
基金the National Natural Science Foundation of China(Grant No.11472137).
文摘This paper proposed an efficient research method for high-dimensional uncertainty quantification of projectile motion in the barrel of a truck-mounted howitzer.Firstly,the dynamic model of projectile motion is established considering the flexible deformation of the barrel and the interaction between the projectile and the barrel.Subsequently,the accuracy of the dynamic model is verified based on the external ballistic projectile attitude test platform.Furthermore,the probability density evolution method(PDEM)is developed to high-dimensional uncertainty quantification of projectile motion.The engineering example highlights the results of the proposed method are consistent with the results obtained by the Monte Carlo Simulation(MCS).Finally,the influence of parameter uncertainty on the projectile disturbance at muzzle under different working conditions is analyzed.The results show that the disturbance of the pitch angular,pitch angular velocity and pitch angular of velocity decreases with the increase of launching angle,and the random parameter ranges of both the projectile and coupling model have similar influence on the disturbance of projectile angular motion at muzzle.
文摘Artificial intelligence(AI),particularly machine learning(ML)and deep learning(DL)techniques,such as convolutional neural networks(CNNs),have emerged as transformative technologies with vast potential in healthcare.Body iron load is usually assessed using slightly invasive blood tests(serum ferritin,serum iron,and serum transferrin).Serum ferritin is widely used to assess body iron and drive medical management;however,it is an acute phase reactant protein offering wrong interpretation in the setting of inflammation and distressed patients.Magnetic resonance imaging is a non-invasive technique that can be used to assess liver iron.The ML and DL algorithms can be used to enhance the detection of minor changes.However,a lack of open-access datasets may delay the advancement of medical research in this field.In this letter,we highlight the importance of standardized datasets for advancing AI and CNNs in medical imaging.Despite the current limitations,embracing AI and CNNs holds promise in revolutionizing disease diagnosis and treatment.
文摘Short-chain fatty acids (SCFA) play an important role in human biochemistry. They originate primarily from the digestive system through carbohydrates microbial fermentation. Most SCFA produced in the colon are absorbed by the intestinal wall and enter the bloodstream to be distributed throughout the body for multiple purposes. At the intestinal level, SCFA play a role in controlling fat storage and fatty acid metabolism. The effects of these beneficial compounds therefore concern overall health. They facilitate energy expenditure and are valuable allies in the fight against obesity and diabetes. SCFA are also involved in the regulation of the levels of several neurotransmitters such as GABA (γ-aminobutyric acid), glutamate, serotonin, dopamine, and norepinephrine. Their role is also highlighted in many inflammatory and neurodegenerative diseases such as Alzheimer’s disease (AD) or Parkinson’s disease (PD). To have a realistic picture of the distribution of SCFA in different biological compartments of the human body, we propose to study SCFA simultaneously in five human biological samples: feces, saliva, serum, cerebrospinal fluid (CSF), and urine, as well as in Dried Blood Spot (DBS). To evaluate their concentration and repeatability, we used 10 aliquots from pooled samples, analyzed by 3-nitrophenylhydrazine (3-NPH) derivation and liquid chromatography coupled with high sensitivity mass spectrometry (LC-QqQ-MS). We also evaluated the SCFA assay on Dried Blood Spot (DBS). In this work, we adapted the pre-analytical parts for each sample to be able to use a common calibration curve, thus facilitating multi-assay quantification studies and so being less time-consuming. Moreover, we proposed new daughter ions from the same neutral loss (43 Da) to quantify SCFAs, thus improving the sensitivity. In conclusion, our methodology, based on a unique calibration curve for all samples for each SCFA, is well-suited to quantified them in a clinical context.
文摘Real-time PCR is a closed DNA amplification system that skillfully integrates biochemical, photoelectric and computer techniques. Fluorescence data acquired once per cycle provides rapid absolute quantification of initial template copy numbers as PCR products are generated. This technique significantly simplifies and accelerates the process of producing reproducible quantification of nucleic acid molecules. It not only is a sensitive, accurate and rapid quantitative method, but it also provides an easier way to calculate the absolute starting copy number of nucleic acid molecules to be tested. Together with molecular bio-techniques, like microarray, real-time PCR will play a very important role in many aspects of molecular life science such as functional gene analysis and disease molecular diagnostics. This review introduces the detailed principles and application of the real-time PCR technique, describes a recently developed system for exact quantification of AUX/IAA genes In Arabidopsis, and discusses the problems with the real-time PCR process.
文摘AIM To investigate and compare the analytical and clinical performance of Tian Long automatic hypersensitive hepatitis B virus(HBV) DNA quantification system and Roche CAP/CTM system.METHODS Two hundred blood samples for HBV DNA testing, HBV-DNA negative samples and high-titer HBV-DNA mixture samples were collected and prepared. National standard materials for serum HBV and a worldwide HBV DNA panel were employed for performance verification. The analytical performance, such as limit of detection, limit of quantification, accuracy, precision, reproducibility, linearity, genotype coverage and cross-contamination, was determined using the Tian Long automatic hypersensitive HBV DNA quantification system(TL system). Correlation and Bland-Altman plot analyses were carried out to compare the clinical performance of the TL system assay and the CAP/CTM system. RESULTS The detection limit of the TL system was 10 IU/m L, and its limit of quantification was 30 IU/m L. The differences between the expected and tested concentrations of the national standards were less than ± 0.4 Log10 IU/m L, which showed high accuracy of the system. Results of the precision, reproducibility and linearity tests showed that the multiple test coefficient of variation(CV) of the same sample was less than 5% for 102-106 IU/m L; and for 30-108 IU/m L, the linear correlation coefficient r2 = 0.99. The TL system detected HBV DNA(A-H) genotypes and there was no cross-contamination during the "checkerboard" test. When compared with the CAP/CTM assay, the two assays showed 100% consistency in both negative and positive sample results(15 negative samples and 185 positive samples). No statistical differences between the two assays in the HBV DNA quantification values were observed(P > 0.05). Correlation analysis indicated a significant correlation between the two assays, r2 = 0.9774. The Bland-Altman plot analysis showed that 98.9% of the positive data were within the 95% acceptable range, and the maximum difference was-0.49.CONCLUSION The TL system has good analytical performance, and exhibits good agreement with the CAP/CTM system in clinical performance.
基金Supported by National Science and Technology Major Project of China,No.2012ZX10002007-001-002 and No.2013ZX10002001(to Zhang JM)the National Natural Science Foundation of China,No.81271833 and No.81471933(to Zhang JM)+1 种基金the Science and Technology Plan Project of Taizhou,Zhejiang province,No.1402ky19(to Tu WH and Hou W)the Scientific Research Project of Taizhou University,Zhejiang province,No:2014PY054(to Tu WH and Hou W)
文摘AIM:To investigate precore/basal core promoter(PC/BCP) mutants throughout hepatitis B virus(HBV) infection and to determine their relationship to hepatitis B early antigen(HBeA g) titers.METHODS:We enrolled 191 patients in various stages of HBV infection at the Huashan Hospital and the Taizhou Municipal Hospital from 2010 to 2012.None of the patients received antiviral therapy.HBV DNA from serum,was quantified by real-time PCR.The HBV genotype was determined by direct sequencing of the S gene.We used the Simpleprobe ultrasensitivequantitative method to detect PC/BCP mutants in each patient.We compared the strain number,percentage,and the changes in PC/BCP mutants in different phases,and analyzed the relationship between PC/BCP mutants and HBe Ag by multiple linear regression and logistic regression.RESULTS:Patients with HBV infection(n = 191) were assigned to groups by phase:Immune tolerance(IT) = 55,Immune clearance(IC) = 67,Low-replicative(LR) = 49,and HBeA g-negative hepatitis(ENH) = 20.Of the patients(male,112; female,79) enrolled,122 were HBe Ag-positive and 69 were HBe Ag-negative.The median age was 33 years(range:18-78 years).PC and BCP mutation detection rates were 84.82%(162/191) and 96.86%(185/191),respectively.In five HBe Ag-negative cases,we detected double mutation G1896A/G1899 A.The logarithm value of PC mutant quantities(log10 PC) significantly differed in IT,IC,and LR phases,as well as in the ENH phase(F = 49.350,P < 0.001).The logarithm value of BCP mutant quantities(log10 BCP) also differed during the four phases(F = 25.530,P < 0.001).Log10 PC and log10 BCP values were high in the IT and IC phases,decreased in the LR phase,and increased in the ENH phase,although the absolute value at this point remained lower than that in the IT and IC phases.PC mutant quantity per total viral load(PC%) and BCP mutant quantity per total viral load(BCP%) differed between phases(F = 20.040,P < 0.001; F = 10.830,P < 0.001),with PC% and BCP% gradually increasing in successive phases.HBeA g titers negatively correlated with PC%(Spearman's rho =-0.354,P < 0.001) and BCP%(Spearman's rho =-0.395,P < 0.001).The negative correlation between PC% and HBeA g status was significant(B =-5.281,P = 0.001),but there was no such correlation between BCP% and HBeA g status(B =-0.523,P = 0.552).CONCLUSION:PC/BCP mutants become predominant in a dynamic and continuous process.Log10 PC,log10 BCP,PC% and BCP% might be combined to evaluate disease progression.PC% determines HBeA g status.
基金the financial support of the Science and Technology Innovation Program of Hunan Province(2020RC5003)the research and application of key technologies for zero-energy buildings based on distributed energy storage and air conditioning demand response(2020-K-165)+1 种基金the Technology Innovation Program of Hunan Province(2017XK2015)the Technology Innovation Program of Hunan Province(2020RC2017)。
文摘This paper reviews recent research on the demand flexibility of residential buildings in regard to definitions,flexible loads,and quantification methods.A systematic distinction of the terminology is made,including the demand flexibility,operation flexibility,and energy flexibility of buildings.A comprehensive definition of building demand flexibility is proposed based on an analysis of the existing definitions.Moreover,the flexibility capabilities and operation characteristics of the main residential flexible loads are summarized and compared.Models and evaluation indicators to quantify the flexibility of these flexible loads are reviewed and summarized.Current research gaps and challenges are identified and analyzed as well.The results indicate that previous studies have focused on the flexibility of central air conditioning,electric water heaters,wet appliances,refrigerators,and lighting,where the proportion of studies focusing on each of these subjects is 36.7%,25.7%,14.7%,9.2%,and 8.3%,respectively.These flexible loads are different in running modes,usage frequencies,seasons,and capabilities for shedding,shifting,and modulation,while their response characteristics are not yet clear.Furthermore,recommendations are given for the application of white-,black-,and grey-box models for modeling flexible loads in different situations.Numerous static flexibility evaluation indicators that are based on the aspects of power,temporality,energy,efficiency,economics,and the environment have been proposed in previous publications,but a consensus and standardized evaluation framework is lacking.This review can help readers better understand building demand flexibility and learn about the characteristics of different residential flexible loads,while also providing suggestions for future research on the modeling techniques and evaluation metrics of residential building demand flexibility.
基金Supported by the National Natural Science Foundation of China (No.20336010 and No.20176025).
文摘To establish a rapid quantification method for heparinase I during its production in recombinant Escherichia coli, a translational fusion vector was constructed by fusing the N terminus of heparinase I to the C terminus of a green fluorescent protein mutant (GFPmutl). As a result, not only was the functional recombinant expression of heparinase I in E. coli accomplished, but also a linear correlation was obtained between the GFP fluorescence intensity and heparinase I activity, allowing enzyme activity to be quantified rapidly during the fermentation.
基金Supported by Grants from Medical Scientific Research Foundation of Guangdong Province, China, No. B2008128National Natural Science Foundation of China, No. 30930027 and No. 60971075, in part
文摘AIM: To evaluate the feasibility of quantifying liver choline concentrations in both normal and apoptotic rabbit livers in vivo, using 1H magnetic resonance spectroscopy (1H-MRS). METHODS: 1H-MRS was performed in 18 rabbits using a 1.5T GE MR system with an eight-channel head/neck receiving coil. Fifteen rabbits were injected with sodium selenite at a dose of 10 μmol/kg to induce the liver cell apoptosis. Point-resolved spectroscopy sequencelocalized spectra were obtained from 10 livers once before and once 24 h after sodium selenite injection in vivo. T1 and T2 relaxation time of water and choline was measured separately in the livers of three healthy rabbits and three selenite-treated rabbits. Hematoxylin and eosin and dUTP-biotin nick end labeling (TUNEL) staining was used to detect and confirm apoptosis. Choline peak areas were measured relative to unsuppressed water using LCModel. Relaxation attenuation was corrected using the average of T1 and T2 relaxation time. The choline concentration was quantified using a formula, which was tested by a phantom with a known concentration. RESULTS: Apoptosis of hepatic cells was confirmed by TUNEL assay. In phantom experiment, the choline concentration (3.01 mmol/L), measured by 1H-MRS, was in good agreement with the actual concentration (3 mmol/L). The average T1 and T2 relaxation time of choline was 612 ± 15 ms and 74 ± 4 ms in the control group and 670 ± 27 ms and 78 ± 5 ms in apoptotic livers in vivo, respectively. Choline was quantified in 10 rabbits, once before and once after the injection with sodium selenite. The choline concentration decreased from 14.5 ± 7.57 mmol/L before sodium selenite injection to 10.8 ± 6.58 mmol/L (mean ± SD, n = 10) after treatment (Z = -2.395, P < 0.05, two-sample paired Wilcoxon test). CONCLUSION: 1H-MRS can be used to quantify liver choline in vivo using unsuppressed water as an internal reference. Decreased liver choline concentrations are found in sodium selenite-treated rabbits undergoing liver cell apoptosis.
基金Shanghai Health and Family Planning Commission,No.201440051Shanghai Pudong New Area Health and Family Planning Commission,No.PW2016A-19
文摘BACKGROUND Diabetic kidney disease(DKD)is a common complication of diabetes.The patient’s prognosis is poor once DKD progresses to advanced stage.Accurate diagnosis and timely treatment of early DKD are important for improving patient’s prognosis and reducing mortality.AIM To explore the value of elastography point quantification(ElastPQ)in improving the accuracy of early DKD diagnosis.METHODS A total of 69 patients with type 2 diabetes were recruited from Naval Military Medical University Affiliated Gongli Hospital.Patients were divided into early DKD group and medium DKD group according to pathological results and urinary albumin excretion rate(UAER).Another 40 patients with simple diabetes were included as the diabetes group.The baseline data,laboratory diagnostic indicators,and ultrasound indicators for each patient were recorded.The differences of the indicators in the three groups were compared.Multivariate logistic regression was used to analyze the influencing factors of the development from simple diabetes into early DKD and from early DKD into medium DKD.Receiver operating characteristic analyses of potential indicators in identifying early DKD and medium DKD,and early DKD and simple diabetes were established.RESULTS Multivariate logistic regression analysis showed that UAER(P<0.001),renocortical Young's Modulus(YM)(P<0.001),and renal parenchymal thickness(P=0.013)were the independent influencing factors of the development from early DKD into medium DKD.Diabetes duration(P=0.041),UAER(P=0.034),and renocortical YM(P=0.017)were the independent influencing factors of the development from simple diabetes into early DKD.Receiver operating characteristic analysis indicated that UAER,renocortical YM,and renal parenchymal thickness were accurate in identifying early DKD and medium DKD[all area under curve(AUC)>0.9].The accuracy of UAER(AUC=0.744),diabetes duration(AUC=0.757),and renocortical YM(AUC=0.782)for the diagnosis of early DKD and simple diabetes were limited.However,the combined diagnosis of UAER,diabetes duration,and renocortical YM was accurate in identifying early DKD and simple diabetes(AUC=0.906),which was significantly higher than any of the three indicators(all P<0.05).CONCLUSION ElastPQ is of great value in the diagnosis of early DKD.When combined with the diabetes duration and UAER,it is expected to diagnose accurately early DKD.
基金supported by the Advanced Research of National Defense Foundation of China(426010501)
文摘As an alternative or complementary approach to the classical probability theory,the ability of the evidence theory in uncertainty quantification(UQ) analyses is subject of intense research in recent years.Two state-of-the-art numerical methods,the vertex method and the sampling method,are commonly used to calculate the resulting uncertainty based on the evidence theory.The vertex method is very effective for the monotonous system,but not for the non-monotonous one due to its high computational errors.The sampling method is applicable for both systems.But it always requires a high computational cost in UQ analyses,which makes it inefficient in most complex engineering systems.In this work,a computational intelligence approach is developed to reduce the computational cost and improve the practical utility of the evidence theory in UQ analyses.The method is demonstrated on two challenging problems proposed by Sandia National Laboratory.Simulation results show that the computational efficiency of the proposed method outperforms both the vertex method and the sampling method without decreasing the degree of accuracy.Especially,when the numbers of uncertain parameters and focal elements are large,and the system model is non-monotonic,the computational cost is five times less than that of the sampling method.
基金Supported by the Yunnan Provincial Sciences and Technology Department,China (No. 2007AD009)the National Natural Science Foundation of China (No. CNSF30570183)the Knowledge Innovation Program of Chinese Academy of Sciences (No. KSCX2-YW-G-060)
文摘The influence of alkali on astaxanthin and the optimal working wave length for measurement of astaxanthin from Haematocoecus crude extract were investigated, and a spectrophotometric method for precise quantification of the astaxanthin based on the method of Boussiba et al. was established. According to Boussiba's method, alkali treatment destroys chlorophyll. However, we found that: 1) carotenoid content declined for about 25% in Haematococcus fresh cysts and up to 30% in dry powder of Haematococcus broken cysts after alkali treatment; and 2) dimethyl sulfoxide (DMSO)-extracted chlorophyll of green Haematococeus bares little absorption at 520-550 nm. Interestingly, a good linear relationship existed between absorbance at 530 nm and astaxanthin content, while an unknown interference at 540-550 nm was detected in our study. Therefore, with 530 nm as working wavelength, the alkali treatment to destroy chlorophyll was not necessary and the influence of chlorophyll, other carotenoids, and the unknown interference could be avoided. The astaxanthin contents of two samples were measured at 492 nm and 530 nm; the measured values at 530 nm were 2.617 g/100 g and 1.811 g/100 g. When compared with the measured values at 492 nm, the measured values at 530 nm decreased by 6.93% and 11.96%, respectively. The measured values at 530 nm are closer to the true astaxanthin contents in the samples. The data show that 530 nm is the most suitable wave length for spectrophotometric determination to the astaxanthin in Haematococcus crude extract.
基金Project 106084 supported by the Scientific and Technological Research of the Ministry of EducationBK2007701 by the Natural Science Foundation ofJisngsu Province2006CB2022010 by the National Basic Research Program of China and the Qing-lan Project of Jiangsu Province
文摘Hundreds of mine flooding accidents have occurred in China since the 1950s. These flooding accidents result in submerged working faces, even entire coal mines, leading to tremendous economic losses. It is reported that among 601 state-owned mines in China, 285 mines are exposed to water-inrush risks. The water pressure is becoming larger and larger with the increase of mining depth, leading to an increase of water-inrush hazards. Only when the risk of mine flooding is predicted in a reasonable manner, can we take timely and effective measures to prevent mine flooding from taking place. In our investigation quantification(H) theory is used to study the risk prediction problem about mine flooding. By investigating the main factors which affect mine flooding, eight risk assessment items have been identified. The extent of risk is classified into 4 grades. Given the data from different periods in the Feicheng mining area, a prediction model for the risk of mine flooding is established. The test analysis indicates a model correlation coefficient of 0.97 and the incidence of discrimination is as high as 97.37%, which implies that the effect of the model is quite satisfactory. With the help of computers, this method can be widely applied.
基金Supported by the National Natural Science Foundation of China (20836004 20806046) the Special Fund for Major State Basic Research Program of China (2009CB724702) the National High Technology Research and Development Program ofChina (2009AA062903)
文摘Green fluorescent protein (GFP) and its variants /homolog proteins are generally called as GFP-like fluorescent proteins (FPs), which are widely used as visible molecular tools for monitoring a wide range of biological processes due to their capability of simple, accurate and real time quantification. The FPs-based molecular and visible quantification tools are giving more impact on bioprocess engineering, enabling the biomolecule-level dynamic information to be linked with the process-level events. In this review, different applications of FPs in biological engineering with emphasis on rapid molecular bioprocess quantification, such as quantification of the transcription efficiency, the protein production, the protein folding efficiency, the cell concentration, the intracellular microenvironments and so on, would be first introduced. The challenges of using FPs with respect to actual bioprocess applications for the precise quantification including the interaction of FPs and the fused partner proteins, the maturation of FPs, the inner filter effect and sensing technology were then discussed. Finally, the future development for the FPs used in molecular bioprocess quantification would be proposed.
文摘A simple and accurate high-performance liquid chromatography(HPLC)coupled with diode array detector(DAD)and evaporative light scattering detector(ELSD)was established for the determination of six bioactive compounds in Zhenqi Fuzheng preparation(ZFP).The monitoring wavelengths were 254,275 and 328 nm.Under the optimum conditions,good separation was achieved,and the assay was fully validated in respect of precision,repeatability and accuracy.The proposed method was successfully applied to quantify the six ingredients in 31 batches of ZFP samples and evaluate the variation by hierarchical cluster analysis(HCA),which demonstrated significant variations on the content of these compounds in the samples from different manufacturers with different preparation procedures.The developed HPLC method can be used as a valid analytical method to evaluate the intrinsic quality of this preparation.
基金the National Natural Science Foundation of China(No.60672145).
文摘The quantificational and normative design is the precondition of improving the design of copper staves for blast furnaces. Based on a 3-dimensional temperature field calculation model, from the view point of heat transfer and long campaigns note with the core of forming accretion, the forming-accretion-ability (FAA) and the rib hot surface maximum temperature difference (ATmax) as quantificational indexes to direct and evaluate the design of copper staves for blast furnaces were presented. The application of the two indexes in design essentially embodies the new long campaigns in the stage of design. With the application of the two indexes, good results can be obtained. Firstly, it was suggested that the rib height of a copper stave can be reduced to 15 mm, which is a new method and theory for the reduction of copper staves. Secondly, the influence of insert on FAA and ATmax, is decided by the volume of insert. According to this, the principle of design for the hot surface geometry of copper staves was put forward that the ratio of the rib hot surface to the copper stave hot surface (abbreviated as the ratio of rib to stave) must be maintained in the range of 45% to 55%; for the present copper stave with a 35-40 mm thick rib, the ratio of rib to stave in the range of 50% to 55% can optimize the design of copper staves; for the copper stave with a smaller rib thickness, for example 15 ram, the ratio of rib to stave in the range of 45% to 50% can optimize the design of copper staves. It can be summarized that the thicker the rib thickness, the larger is the ratio of rib to stave. 2008 University of Science and Technology Beijing. All rights reserved.