期刊文献+
共找到794,029篇文章
< 1 2 250 >
每页显示 20 50 100
Design of a Proportional-Integral-Derivative Controller for an Automatic Generation Control of Multi-area Power Thermal Systems Using Firefly Algorithm 被引量:6
1
作者 K.Jagatheesan B.Anand +3 位作者 Sourav Samanta Nilanjan Dey Amira S.Ashour Valentina E.Balas 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI CSCD 2019年第2期503-515,共13页
Essentially, it is significant to supply the consumer with reliable and sufficient power. Since, power quality is measured by the consistency in frequency and power flow between control areas. Thus, in a power system ... Essentially, it is significant to supply the consumer with reliable and sufficient power. Since, power quality is measured by the consistency in frequency and power flow between control areas. Thus, in a power system operation and control,automatic generation control(AGC) plays a crucial role. In this paper, multi-area(Five areas: area 1, area 2, area 3, area 4 and area 5) reheat thermal power systems are considered with proportional-integral-derivative(PID) controller as a supplementary controller. Each area in the investigated power system is equipped with appropriate governor unit, turbine with reheater unit, generator and speed regulator unit. The PID controller parameters are optimized by considering nature bio-inspired firefly algorithm(FFA). The experimental results demonstrated the comparison of the proposed system performance(FFA-PID)with optimized PID controller based genetic algorithm(GAPID) and particle swarm optimization(PSO) technique(PSOPID) for the same investigated power system. The results proved the efficiency of employing the integral time absolute error(ITAE) cost function with one percent step load perturbation(1 % SLP) in area 1. The proposed system based FFA achieved the least settling time compared to using the GA or the PSO algorithms, while, it attained good results with respect to the peak overshoot/undershoot. In addition, the FFA performance is improved with the increased number of iterations which outperformed the other optimization algorithms based controller. 展开更多
关键词 Automatic generation control(AGC) FIREFLY ALGORITHM GENETIC algorithm(GA) particle SWARM optimization(PSO) proportional-integral-derivative(PID) controller
在线阅读 下载PDF
A Hybrid Firefly Algorithm for Optimizing Fractional Proportional-Integral-Derivative Controller in Ship Steering 被引量:1
2
作者 薛晗 邵哲平 +2 位作者 潘家财 赵强 马峰 《Journal of Shanghai Jiaotong university(Science)》 EI 2016年第4期419-423,共5页
In this paper, a new algorithm which integrates the powerful firefly Mgorithm (FA) and the ant colony optimization (ACO) has been used in tracking control of ship steering for optimization of fractional-order prop... In this paper, a new algorithm which integrates the powerful firefly Mgorithm (FA) and the ant colony optimization (ACO) has been used in tracking control of ship steering for optimization of fractional-order proportional-integral-derivative (FOPID) controller gains. Particle swarm optimization (PSO) algorithm is also used to optimize FOPID controllers, and their performances are compared. It is found that FA optimized FOPID controller gives better performance than others. Sensitivity analysis has been carried out to see the robustness of optimum FOPID gains obtained at nominal conditions to wide changes in system parameters, and the optimum FOPID gains need not be reset for wide changes in system parameters. 展开更多
关键词 firefly algorithm (FA) fractional-order proportional-integral-derivative (FOPID) ant colony optimization (ACO) tracking control ship steering
原文传递
Multivariable Nonlinear Proportional-Integral-Derivative Decoupling Control Based on Recurrent Neural Networks 被引量:6
3
作者 张燕 陈增强 +1 位作者 杨鹏 袁著祉 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2004年第5期677-681,共5页
A nonlinear proportional-integral-derivative (PID) controller is constructed based on recurrent neural networks. In the control process of nonlinear multivariable systems, several nonlinear PID controllers have been a... A nonlinear proportional-integral-derivative (PID) controller is constructed based on recurrent neural networks. In the control process of nonlinear multivariable systems, several nonlinear PID controllers have been adopted in parallel. Under the decoupling cost function, a decoupling control strategy is proposed. Then the stability condition of the controller is presented based on the Lyapunov theory. Simulation examples are given to show effectiveness of the proposed decoupling control. 展开更多
关键词 process control reaction engineering neural network
在线阅读 下载PDF
Proportional-integral-derivative control of nonlinear half-car electro-hydraulic suspension systems
4
作者 John E. D. EKORU Jimoh O. PEDRO 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2013年第6期401-416,共16页
This paper presents the development of a proportional-integral-derivative (PID)-based control method for application to active vehicle suspension systems (AVSS). This method uses an inner PID hydraulic actuator force ... This paper presents the development of a proportional-integral-derivative (PID)-based control method for application to active vehicle suspension systems (AVSS). This method uses an inner PID hydraulic actuator force control loop, in combination with an outer PID suspension travel control loop, to control a nonlinear half-car AVSS. Robustness to model uncertainty in the form of variation in suspension damping is tested, comparing performance of the AVSS with a passive vehicle suspension system (PVSS), with similar model parameters. Spectral analysis of suspension system model output data, obtained by performing a road input disturbance frequency sweep, provides frequency response plots for both nonlinear vehicle suspension systems and time domain vehicle responses to a sinusoidal road input disturbance on a smooth road. The results show the greater robustness of the AVSS over the PVSS to parametric uncertainty in the frequency and time domains. 展开更多
关键词 Force control proportional-integral-derivative (PID) control Nonlinear half-car Active vehicle suspension system (AVSS) Hydraulic actuator dynamics Model uncertainty
原文传递
Feedforward Variable Structural Proportional-Integral-Derivative for Temperature Control of Polymerase Chain Reaction 被引量:3
5
作者 邱宪波 袁景淇 汪志锋 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2006年第2期200-206,共7页
To track the rapidly changing temperature profiles of thermal cycling of polymerase chain reaction (PCR) accurately, an innovative feedforward variable structural proportional-integral-derivative (FVSPID) controll... To track the rapidly changing temperature profiles of thermal cycling of polymerase chain reaction (PCR) accurately, an innovative feedforward variable structural proportional-integral-derivative (FVSPID) controller was developed. Based on the step response test data of the heat block, a reduced first order model was estabfished at different operating points. Based on the reduced model, the FVSPID controller combined a feedforward path with the variable structural proportional-integral-derivative (PID) control. The modified feedforward action provided directly the optimal predictive power for the desired setpoint to speed up the dynamic response. To cooperate with the feedforward action, a variable structural PID was applied, where the P mode was used in the case of the largest errors to speed up response, whereas the PD mode was used in the case of larger errors to suppress overshoot, and finally the PID mode was applied for small error conditions to eliminate the steady state offset. Experimental results illustrated that compared to the conventional PID controller, the FVSPID controller can not only reduce the time taken to complete a standard PCR protocol, but also improve the accuracy of gene amplification. 展开更多
关键词 feedforward variable structural PID controller polymerase chain reaction thermal cycling temperature tracking
在线阅读 下载PDF
Robust Backstepping Control of a Quadrotor Unmanned Aerial Vehicle under Colored Noises
6
作者 Mehmet Karahan 《Computers, Materials & Continua》 SCIE EI 2025年第1期777-798,共22页
Advances in software and hardware technologies have facilitated the production of quadrotor unmanned aerial vehicles(UAVs).Nowadays,people actively use quadrotor UAVs in essential missions such as search and rescue,co... Advances in software and hardware technologies have facilitated the production of quadrotor unmanned aerial vehicles(UAVs).Nowadays,people actively use quadrotor UAVs in essential missions such as search and rescue,counter-terrorism,firefighting,surveillance,and cargo transportation.While performing these tasks,quadrotors must operate in noisy environments.Therefore,a robust controller design that can control the altitude and attitude of the quadrotor in noisy environments is of great importance.Many researchers have focused only on white Gaussian noise in their studies,whereas researchers need to consider the effects of all colored noises during the operation of the quadrotor.This study aims to design a robust controller that is resistant to all colored noises.Firstly,a nonlinear quadrotormodel was created with MATLAB.Then,a backstepping controller resistant to colored noises was designed.Thedesigned backstepping controller was tested under Gaussian white,pink,brown,blue,and purple noises.PID and Lyapunov-based controller designswere also carried out,and their time responses(rise time,overshoot,settling time)were compared with those of the backstepping controller.In the simulations,time was in seconds,altitude was in meters,and roll,pitch,and yaw references were in radians.Rise and settling time values were in seconds,and overshoot value was in percent.When the obtained values are examined,simulations prove that the proposed backstepping controller has the least overshoot and the shortest settling time under all noise types. 展开更多
关键词 Backstepping control colored noises Gaussian noise Lyapunov stability QUADROTOR ROBUSTNESS PID control
在线阅读 下载PDF
Coordinated Control Strategy of New Energy Power Generation System with Hybrid Energy Storage Unit
7
作者 Yun Zhang Zifen Han +2 位作者 Biao Tian Ning Chen Yi Fan 《Energy Engineering》 EI 2025年第1期167-184,共18页
The new energy power generation is becoming increasingly important in the power system.Such as photovoltaic power generation has become a research hotspot,however,due to the characteristics of light radiation changes,... The new energy power generation is becoming increasingly important in the power system.Such as photovoltaic power generation has become a research hotspot,however,due to the characteristics of light radiation changes,photovoltaic power generation is unstable and random,resulting in a low utilization rate and directly affecting the stability of the power grid.To solve this problem,this paper proposes a coordinated control strategy for a newenergy power generation system with a hybrid energy storage unit based on the lithium iron phosphate-supercapacitor hybrid energy storage unit.Firstly,the variational mode decomposition algorithm is used to separate the high and low frequencies of the power signal,which is conducive to the rapid and accurate suppression of the power fluctuation of the energy storage system.Secondly,the fuzzy control algorithm is introduced to balance the power between energy storage.In this paper,the actual data is used for simulation,and the simulation results show that the strategy realizes the effective suppression of the bus voltage fluctuation and the accurate control of the internal state of the energy storage unit,effectively avoiding problems such as overshoot and over-discharge,and can significantly improve the stability of the photovoltaic power generation systemand the stability of the Direct Current bus.It is of great significance to promote the development of collaborative control technology for photovoltaic hybrid energy storage units. 展开更多
关键词 Photovoltaic power suppression hybrid energy storage unit variationalmodal decomposition fuzzy control power distribution control
在线阅读 下载PDF
Advanced Functional Electromagnetic Shielding Materials:A Review Based on Micro‑Nano Structure Interface Control of Biomass Cell Walls
8
作者 Yang Shi Mingjun Wu +14 位作者 Shengbo Ge Jianzhang Li Anoud Saud Alshammari Jing Luo Mohammed A.Amin Hua Qiu Jinxuan Jiang Yazeed M.Asiri Runzhou Huang Hua Hou Zeinhom M.El‑Bahy Zhanhu Guo Chong Jia Kaimeng Xu Xiangmeng Chen 《Nano-Micro Letters》 SCIE EI CAS 2025年第1期98-134,共37页
Research efforts on electromagnetic interference(EMI)shielding materials have begun to converge on green and sustainable biomass materials.These materials offer numerous advantages such as being lightweight,porous,and... Research efforts on electromagnetic interference(EMI)shielding materials have begun to converge on green and sustainable biomass materials.These materials offer numerous advantages such as being lightweight,porous,and hierarchical.Due to their porous nature,interfacial compatibility,and electrical conductivity,biomass materials hold significant potential as EMI shielding materials.Despite concerted efforts on the EMI shielding of biomass materials have been reported,this research area is still relatively new compared to traditional EMI shielding materials.In particular,a more comprehensive study and summary of the factors influencing biomass EMI shielding materials including the pore structure adjustment,preparation process,and micro-control would be valuable.The preparation methods and characteristics of wood,bamboo,cellulose and lignin in EMI shielding field are critically discussed in this paper,and similar biomass EMI materials are summarized and analyzed.The composite methods and fillers of various biomass materials were reviewed.this paper also highlights the mechanism of EMI shielding as well as existing prospects and challenges for development trends in this field. 展开更多
关键词 Biomass materials Electromagnetic interference shielding Micro-nano structure interface control CONDUCTIVITY
在线阅读 下载PDF
A Verifiable Trust-Based CP-ABE Access Control Scheme for Cloud-Assisted Renewable Energy Systems
9
作者 Jiyu Zhang Kehe Wu +4 位作者 Ruomeng Yan Zheng Tian Yizhen Sun Yuxi Wu Yaogong Guo 《Computers, Materials & Continua》 SCIE EI 2025年第1期1211-1232,共22页
Renewable Energy Systems(RES)provide a sustainable solution to climate warming and environmental pollution by enhancing stability and reliability through status acquisition and analysis on cloud platforms and intellig... Renewable Energy Systems(RES)provide a sustainable solution to climate warming and environmental pollution by enhancing stability and reliability through status acquisition and analysis on cloud platforms and intelligent processing on edge servers(ES).However,securely distributing encrypted data stored in the cloud to terminals that meet decryption requirements has become a prominent research topic.Additionally,managing attributes,including addition,deletion,and modification,is a crucial issue in the access control scheme for RES.To address these security concerns,a trust-based ciphertext-policy attribute-based encryption(CP-ABE)device access control scheme is proposed for RES(TB-CP-ABE).This scheme effectivelymanages the distribution and control of encrypted data on the cloud through robust attribute key management.By introducing trust management mechanisms and outsourced decryption technology,the ES system can effectively assess and manage the trust worthiness of terminal devices,ensuring that only trusted devices can participate in data exchange and access sensitive information.Besides,the ES system dynamically evaluates trust scores to set decryption trust thresholds,thereby regulating device data access permissions and enhancing the system’s security.To validate the security of the proposed TB-CP-ABE against chosen plaintext attacks,a comprehensive formal security analysis is conducted using the widely accepted random oraclemodel under the decisional q-Bilinear Diffie-Hellman Exponent(q-BDHE)assumption.Finally,comparative analysis with other schemes demonstrates that the TB-CP-ABE scheme cuts energy/communication costs by 43%,and scaleswell with rising terminals,maintaining average latency below 50ms,ensuring real-time service feasibility.The proposed scheme not only provides newinsights for the secure management of RES but also lays a foundation for future secure energy solutions. 展开更多
关键词 Access control renewable energy systems(RES) ciphertext-policy attribute-based encryption(CP-ABE) security
在线阅读 下载PDF
Integrated Equipment with Functions of Current Flow Control and Fault Isolation for Multiterminal DC Grids
10
作者 Shuo Zhang Guibin Zou 《Energy Engineering》 EI 2025年第1期85-99,共15页
The multi-terminal direct current(DC)grid has extinctive superiorities over the traditional alternating current system in integrating large-scale renewable energy.Both the DC circuit breaker(DCCB)and the current flow ... The multi-terminal direct current(DC)grid has extinctive superiorities over the traditional alternating current system in integrating large-scale renewable energy.Both the DC circuit breaker(DCCB)and the current flow controller(CFC)are demanded to ensure the multiterminal DC grid to operates reliably and flexibly.However,since the CFC and the DCCB are all based on fully controlled semiconductor switches(e.g.,insulated gate bipolar transistor,integrated gate commutated thyristor,etc.),their separation configuration in the multiterminal DC grid will lead to unaffordable implementation costs and conduction power losses.To solve these problems,integrated equipment with both current flow control and fault isolation abilities is proposed,which shares the expensive and duplicated components of CFCs and DCCBs among adjacent lines.In addition,the complicated coordination control of CFCs and DCCBs can be avoided by adopting the integrated equipment in themultiterminal DC grid.In order to examine the current flow control and fault isolation abilities of the integrated equipment,the simulation model of a specific meshed four-terminal DC grid is constructed in the PSCAD/EMTDC software.Finally,the comparison between the integrated equipment and the separate solution is presented a specific result or conclusion needs to be added to the abstract. 展开更多
关键词 Integrated equipment multiterminal direct current grid current flow control fault isolation
在线阅读 下载PDF
Architecture to Secure Electrical Control System in Cyber-Physical System
11
作者 Depeng Li 《Journal of Information Security》 2025年第1期149-157,共9页
It’s possible for malicious operators to seize hold of electrical control systems, for instance, the engine control unit of driverless vehicles, from various vectors, e.g. autonomic control system, remote vehicle acc... It’s possible for malicious operators to seize hold of electrical control systems, for instance, the engine control unit of driverless vehicles, from various vectors, e.g. autonomic control system, remote vehicle access, or human drivers. To mitigate potential risks, this paper provides the inauguration study by proposing a theoretical framework in the physical, human and cyber triad. Its goal is to, at each time point, detect adversary control behaviors and protect control systems against malicious operations via integrating a variety of methods. This paper only proposes a theoretical framework which tries to indicate possible threats. With the support of the framework, the security system can lightly reduce the risk. The development and implementation of the system are out of scope. 展开更多
关键词 ARCHITECTURE control System FRAMEWORK
在线阅读 下载PDF
Output Voltage Stabilization of Non-Ideal DC-DC Zeta Converter with Output Voltage Error Elimination via Hybrid Control
12
作者 Hafez Sarkawi Noridah Mohd Ridzuan +1 位作者 Muhammad Idzdihar Idris Mohd Syafiq Mispan 《Journal of Power and Energy Engineering》 2025年第1期18-31,共14页
In this paper, we proposed an output voltage stabilization of a DC-DC Zeta converter using hybrid control. We modeled the Zeta converter under continuous conduction mode operation. We derived a switching control law t... In this paper, we proposed an output voltage stabilization of a DC-DC Zeta converter using hybrid control. We modeled the Zeta converter under continuous conduction mode operation. We derived a switching control law that brings the output voltage to the desired level. Due to infinite switching occurring at the desired level, we enhanced the switching control law by allowing a sizeable output voltage ripple. We derived mathematical models that allow one to choose the desired switching frequency. In practice, the existence of the non-ideal properties of the Zeta converter results in steady-state output voltage error. By analyzing the power loss in the zeta converter, we proposed an improved switching control law that eliminates the steady-state output voltage error. The effectiveness of the proposed method is illustrated with simulation results. 展开更多
关键词 Continuous Conduction Mode DC-DC Zeta Converter Hybrid control Output Voltage Error Switching control Law Switching Frequency
在线阅读 下载PDF
Grid-Connected/Islanded Switching Control Strategy for Photovoltaic Storage Hybrid Inverters Based on Modified Chimpanzee Optimization Algorithm
13
作者 Chao Zhou Narisu Wang +1 位作者 Fuyin Ni Wenchao Zhang 《Energy Engineering》 EI 2025年第1期265-284,共20页
Uneven power distribution,transient voltage,and frequency deviations are observed in the photovoltaic storage hybrid inverter during the switching between grid-connected and island modes.In response to these issues,th... Uneven power distribution,transient voltage,and frequency deviations are observed in the photovoltaic storage hybrid inverter during the switching between grid-connected and island modes.In response to these issues,this paper proposes a grid-connected/island switching control strategy for photovoltaic storage hybrid inverters based on the modified chimpanzee optimization algorithm.The proposed strategy incorporates coupling compensation and power differentiation elements based on the traditional droop control.Then,it combines the angular frequency and voltage amplitude adjustments provided by the phase-locked loop-free pre-synchronization control strategy.Precise pre-synchronization is achieved by regulating the virtual current to zero and aligning the photovoltaic storage hybrid inverter with the grid voltage.Additionally,two novel operators,learning and emotional behaviors are introduced to enhance the optimization precision of the chimpanzee algorithm.These operators ensure high-precision and high-reliability optimization of the droop control parameters for photovoltaic storage hybrid inverters.A Simulink model was constructed for simulation analysis,which validated the optimized control strategy’s ability to evenly distribute power under load transients.This strategy effectively mitigated transient voltage and current surges during mode transitions.Consequently,seamless and efficient switching between gridconnected and island modes was achieved for the photovoltaic storage hybrid inverter.The enhanced energy utilization efficiency,in turn,offers robust technical support for grid stability. 展开更多
关键词 Photovoltaic storage hybrid inverters modified chimpanzee optimization algorithm droop control seamless switching
在线阅读 下载PDF
Multi-Stage Voltage Control Optimization Strategy for Distribution Networks Considering Active-Reactive Co-Regulation of Electric Vehicles
14
作者 Shukang Lyu Fei Zeng +3 位作者 Huachun Han Huiyu Miao Yi Pan Xiaodong Yuan 《Energy Engineering》 EI 2025年第1期221-242,共22页
The high proportion of uncertain distributed power sources and the access to large-scale random electric vehicle(EV)charging resources further aggravate the voltage fluctuation of the distribution network,and the exis... The high proportion of uncertain distributed power sources and the access to large-scale random electric vehicle(EV)charging resources further aggravate the voltage fluctuation of the distribution network,and the existing research has not deeply explored the EV active-reactive synergistic regulating characteristics,and failed to realize themulti-timescale synergistic control with other regulatingmeans,For this reason,this paper proposes amultilevel linkage coordinated optimization strategy to reduce the voltage deviation of the distribution network.Firstly,a capacitor bank reactive power compensation voltage control model and a distributed photovoltaic(PV)activereactive power regulationmodel are established.Additionally,an external characteristicmodel of EVactive-reactive power regulation is developed considering the four-quadrant operational characteristics of the EVcharger.Amultiobjective optimization model of the distribution network is then constructed considering the time-series coupling constraints of multiple types of voltage regulators.A multi-timescale control strategy is proposed by considering the impact of voltage regulators on active-reactive EV energy consumption and PV energy consumption.Then,a four-stage voltage control optimization strategy is proposed for various types of voltage regulators with multiple time scales.Themulti-objective optimization is solved with the improvedDrosophila algorithmto realize the power fluctuation control of the distribution network and themulti-stage voltage control optimization.Simulation results validate that the proposed voltage control optimization strategy achieves the coordinated control of decentralized voltage control resources in the distribution network.It effectively reduces the voltage deviation of the distribution network while ensuring the energy demand of EV users and enhancing the stability and economic efficiency of the distribution network. 展开更多
关键词 Electric vehicle(EV) distribution network multi-stage optimization active-reactive power regulation voltage control
在线阅读 下载PDF
Cooperative maximum adhesion tracking control for multi-motor electric locomotives
15
作者 Leiting Zhao Yongxiang Wang +3 位作者 Kan Liu Liran Li Jingyuan Zhan Qingliang Liu 《Railway Sciences》 2025年第1期22-36,共15页
Purpose–This study aims to propose a cooperative adhesion control method for trains with multiple motors electric locomotives.The method is intended to optimize the output torque of each motor,maximize the utilizatio... Purpose–This study aims to propose a cooperative adhesion control method for trains with multiple motors electric locomotives.The method is intended to optimize the output torque of each motor,maximize the utilization of train adhesion within the total torque command,reduce the train skidding/sliding phenomenon and achieve optimal adhesion utilization for each axle,thus realizing the optimal allocation of the multi-motor electric locomotives.Design/methodology/approach–In this study,a model predictive control(MPC)-based cooperative maximum adhesion tracking control method for multi-motor electric locomotives is presented.Firstly,train traction system with multiple motors is constructed in accordance with Newton’s second law.These equations include the train dynamics equations,the axle dynamics equations,and the wheel-rail adhesion coefficient equations.Then,a new MPC-based multi-axle adhesion co-optimization method is put forward.This method calculates the optimal output torque through real-time iteration based on the known reference slip speed to achieve multi-axle co-optimization under different circumstances.Findings–This paper presents a MPC system designed for the cooperative control of multi-axle adhesion.The results indicate that the proposed control system is able to optimize the adhesion of multiple axles under numerous different conditions and achieve the optimal power distribution based on the reduction of train skidding/sliding.Originality/value–This study presents a novel cooperative adhesion tracking control scheme.It is designed for multi-motor electric locomotives,which has rarely been studied before.And simulations are carried out in different conditions,including variable surfaces and motor failing. 展开更多
关键词 Cooperative control Adhesion control Model predictive control Slip prevent
在线阅读 下载PDF
Association of the glycemic background patterns and the diabetes management efficacy in poorly controlled type 2 diabetes
16
作者 Ayşe N Erbakan Müzeyyen Arslan Bahadır +6 位作者 FatoşN Kaya Büşra Güleç MiraçVural Keskinler Ümmügülsüm AktemurÇelik Özge Faydalıel Banu Mesçi Aytekin Oğuz 《World Journal of Diabetes》 SCIE 2025年第1期74-90,共17页
BACKGROUND Inadequate glycemic control in patients with type 2 diabetes(T2DM)is a major public health problem and a significant risk factor for the progression of diabetic complications.AIM To evaluate the effects of ... BACKGROUND Inadequate glycemic control in patients with type 2 diabetes(T2DM)is a major public health problem and a significant risk factor for the progression of diabetic complications.AIM To evaluate the effects of intensive and supportive glycemic management strategies over a 12-month period in individuals with T2DM with glycated hemoglobin(HbA1c)≥10%and varying backgrounds of glycemic control.METHODS This prospective observational study investigated glycemic control in patients with poorly controlled T2DM over 12 months.Participants were categorized into four groups based on prior glycemic history:Newly diagnosed,previously well controlled with recent worsening,previously off-target but now worsening,and HbA1c consistently above 10%.HbA1c levels were monitored quarterly,and patients received medical,educational,and dietary support as needed.The analysis focused on the success rates of good glycemic control and the associated factors within each group.RESULTS The study showed significant improvements in HbA1c levels in all participants.The most significant improvement was observed in individuals newly diagnosed with diabetes:65%achieved an HbA1c target of≤7%.The results varied between participants with different glycemic control histories,followed by decreasing success rates:39%in participants with previously good glycemic control,21%in participants whose glycemic control had deteriorated compared to before,and only 10%in participants with persistently poor control,with mean HbA1c levels of 6.3%,7.7%,8.2%,and 9.7%,respectively.After one year,65.2%of the“newly diagnosed patients”,39.3%in the“previously controlled group”,21.9%in the“previously off-target but now worsened'”group and 10%in the“poorly controlled from the start”group had achieved HbA1c levels of 7 and below.CONCLUSION In poorly controlled diabetes,the rate at which treatment goals are achieved is associated with the glycemic background characteristics,emphasizing the need for tailored strategies.Therefore,different and comprehensive treatment approaches are needed for patients with persistent uncontrolled diabetes. 展开更多
关键词 Type 2 diabetes mellitus Glycated hemoglobin Glycemic control Patient-centered care Diabetes management glycemic background
在线阅读 下载PDF
Evaluation of Two Methods of Production and Release of the Parasitoid Habrobracon hebetor Say (Hymenoptera: Braconidae) for the Control of Pearl Millet Head Miner Heliocheilus albipunctella (de Joannis) (Lepidoptera: Noctuidae) in Maradi (Niger)
17
作者 Laouali Amadou Mahaman Nassirou Oumarou +5 位作者 Ousseina Abdoulaye Souleymane Laminou Issa Yacouba Ibrahim Baoua Malick N. Ba Rangaswamy Muniappan 《Advances in Entomology》 2025年第1期126-138,共13页
Pearl millet, Pennisetum glaucum (Leeke) R. Br, is the main cereal crop in Niger. This crop is seriously attacked by the millet Head miner (MHM), Heliocheilus albipunctella (de Joannis) (Lepidoptera, Noctuidae) causin... Pearl millet, Pennisetum glaucum (Leeke) R. Br, is the main cereal crop in Niger. This crop is seriously attacked by the millet Head miner (MHM), Heliocheilus albipunctella (de Joannis) (Lepidoptera, Noctuidae) causing significant yield losses. This study to optimize biological control of this pest was carried out in Niger in the laboratory and in a farming environment. In the laboratory, the larval paralysis and emergence of the parasitoid Habrobracon hebetor Say (Hymenoptera: Braconidae) were compared between release jute bags, plastic boxes and cardboard boxes. In a farming environment, direct releases were carried out with plastic boxes and releases with jute bags in 12 villages of the Maradi region during the cropping seasons of 2021 and 2022. The results indicated that 25 larvae of Corcyra cephalonica Stainton (Lepidoptera: Pyralidae) in the boxes were all paralyzed by 2 females of H. hebetor within 7 hours 30 minutes. The emergence of adults began on the 7th day after the beginning of the experiment for a period of two weeks and three weeks respectively in the boxes and jute bags. The production varied from 107.08 to 110.17 parasitoids and was comparable between the Jute bags, plastic boxes and cardboard boxes. In Farmers’ fields, the parasitoid release with the two methods caused the parasitism rates that varied from 64.32 to 66.52% depending on the year but in 2022 the rate of parasitism was higher in the fields with direct releases using plastic boxes (72.66%) compared to those released with jute bags (56.35%). Plastic boxes and cardboard boxes can be used for the production of the H. hebetor parasitoids. These results can be recommended to the cottage industries in the Sahel in order to improve the production and release methods of H. hebetor and make them more adapted to farmers’ fields. 展开更多
关键词 Biological control Parasitoid Release Hebrobracon hebetor Heliocheilus albipunctella NIGER
在线阅读 下载PDF
Factors Associated with Poor Tension Control in Hypertensive Patients
18
作者 Marguerite Téning Diouf Serigne Fallou Diouf +9 位作者 Papa Adama Faye Joseph Salvator Mingou Malick Ndiaye Ndeye Faye Aimé Mbaye Sy Daouda Timéra Fatou Aw Momar Dioum Alassane Mbaye Abdoul Kane 《World Journal of Cardiovascular Diseases》 2025年第2期127-134,共8页
Introduction: High blood pressure is a major public health issue affecting 1.28 billion people worldwide in 2019, making it the leading chronic disease. Blood pressure control remains particularly difficult, especiall... Introduction: High blood pressure is a major public health issue affecting 1.28 billion people worldwide in 2019, making it the leading chronic disease. Blood pressure control remains particularly difficult, especially in sub-Saharan Africa. The objective of our study was to identify factors associated with poor blood pressure control in hypertensive patients followed up at the cardiology department of the Dalal Jamm National Hospital. Patients and methods: This was a retrospective, descriptive and analytical, single-center cross-sectional study conducted over a 12-month period from January 1, 2021 to December 31, 2021, involving hypertensive patients followed for at least 3 months. The parameters studied were sociodemographic data, cardiovascular risk factors associated with high blood pressure, clinical signs, therapeutic compliance, therapeutic aspects, blood pressure control, and factors associated with poor control. The data were analyzed using RStudio 4.6 software. Result: High blood pressure represented 26.6% (n = 722) of the reasons for consultations and 109 patients were included in the study. We found a female predominance with a sex ratio of 0.48. The mean age of the population was 61.9 years ± 12. The predominant age group was 60 - 80 years representing 67% (n = 73) of patients. Diabetics represented 30% (n = 33) all type 2, 40% (n = 43) had dyslipidemia, 58 women had reached menopause. Sedentary lifestyle was found in 76% of patients, 61% (n = 67) had a family history of hypertension. In addition, 43.5% of the population studied had more than 3 risk factors in addition to hypertension. Patient follow-up was irregular in 21.1%. The mean systolic blood pressure was 162.4 ± 21 mm Hg and diastolic 96.16 ± 13.6 mm Hg. The mean heart rate was 77.84 ± 18.01 beats per minute. Dieulafoy signs were reported in 58% of patients. The low-sodium diet was respected by 77% of patients. Dual therapy was the most prescribed protocol with 42% (n = 46). Among the complications, heart failure was the most frequent (49%), followed by stroke (30%). The Girerd test was applied to assess therapeutic compliance, 30% of patients were good adherents, 43.5% had a minimal problem of adherence and 26.5% were not at all adherent. The blood pressure control rate was 53.20%. In bivariate analysis, sedentary lifestyle (p Conclusion: The management of high blood pressure encounters significant difficulties, resulting in inadequate control of blood pressure figures. Blood pressure was not controlled in almost half of the patients. The factor of poor blood pressure control identified was therapeutic non-compliance. It is imperative to make care more accessible and promote therapeutic education. 展开更多
关键词 Arterial Hypertension Therapeutic Compliance Poor Blood Pressure control DAKAR
在线阅读 下载PDF
Assessment of Local Substrates from Burkina Faso for the Growth of Entomopathogenic Fungi Metarhizium pingshaense for Malaria Vector Control Perspectives
19
作者 Issiaka Sare Carine Letitia Traore +2 位作者 Armel Judicael Lingani Abdoulaye Diabate Etienne Bilgo 《Advances in Microbiology》 2025年第2期126-135,共10页
Malaria is a potentially lethal disease caused by parasites of the Plasmodium genus, transmitted to humans through the bite of infected female mosquitoes, primarily Anopheles. To control this disease, various strategi... Malaria is a potentially lethal disease caused by parasites of the Plasmodium genus, transmitted to humans through the bite of infected female mosquitoes, primarily Anopheles. To control this disease, various strategies are implemented, including biological control, which targets the vectors of the parasite. This approach uses biological agents such as entomopathogenic fungi, including Metarhizium pingshaense, a fungus capable of causing lethal infections in mosquitoes. The production of Metarhizium pingshaense is still limited in Burkina Faso, and local cultivation of this fungus could help fill this gap. A study was conducted to identify optimal local substrates that promote its growth. Indeed, after gathering information on the dietary habits of populations in Bobo-Dioulasso and Bama, three potential substrates were selected: rice, cornmeal dough (MFL), and beans. These substrates were inoculated with two strains of Metarhizium pingshaense (S10 and S26) to assess their ability to support fungal growth and their effectiveness. Experimental results showed that MFL and bean substrates favored optimal growth of Metarhizium pingshaense, with growths of 1.91 cm and 2.13 cm after 8 days, compared to 1.83 cm on a standard media (PDA). In terms of virulence, S26 strain caused 60% mosquito mortality on both the bean and PDA media, while S10 strain induced mortalities of 50% for bean and 62% for PDA. 展开更多
关键词 MALARIA ANOPHELES Biological control Metarhizium pingshaense Local Culture Media Burkina Faso
在线阅读 下载PDF
Quality Control and Optimization of Computed Tomography Dose Index Volume (CTDIvol) of LightSpeed RT16 Xtra CT Scanner
20
作者 Umme Sadia Binte Kashem Shirin Akter +4 位作者 Afroza Shelley Rajada Khatun Ashrafun Nahar Monika Laila Sharmin Md. Anwarul Islam 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2025年第1期1-13,共13页
Dose estimation and quality control in computed tomography (CT) scanners are useful in controlling the dose of radiation given to patients while tests are carried out. The study was performed in a 16-slice Computed To... Dose estimation and quality control in computed tomography (CT) scanners are useful in controlling the dose of radiation given to patients while tests are carried out. The study was performed in a 16-slice Computed Tomography (CT) system of LightSpeed RT16 Xtra CT scanner. Quality control was done using a vendor-provided QA Phantom, and the six aspects of image quality were measured. For CT dosimetry, Computed Tomography Dose index volume (CTDIvol) was performed using Computed Tomography Dose Index (CTDI) Phantom. CTDI Phantom consists of three parts: Pediatric Head, Adult Head, and Adult Body Phantom. A 10 cm long pencil ion chamber DCT-10 was used to measure the dose at different positions inside the CTDI Phantom. Data were collected using MagicMax Universal software. For dose estimation of the CTDIvol Report of AAPM Task Group, 96 and 111 formalisms were used. For Pediatric Head, Adult Head, and Adult Body Phantom the measured CIDIvol was 61.04 mGy, 48.11 mGy, and 18.08 mGy respectively. The study has shown deviations of 7%, 15%, and 19% between estimated and console-displayed doses for Pediatric Head, Adult Head, and Adult Body scan techniques respectively. The six aspects of image quality measured by QA Phantom were found to be compatible with the specifications of the machine and CTDIvol measured by CTDI Phantom were found within a tolerance limit of ±20%. Hence, the QC and dosimetry of the mentioned machine are within the limit. 展开更多
关键词 Quality control CTDIvol LightSpeed RT16 Xtra CT Scanner PHANTOM
在线阅读 下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部