The polytetrafluoroethylene fiber grafted acrylic acid was used as a cation exchanger. The exchange capacity of the cation fiber is 3.06 mmol/g. The maximum Cu2+ adsorption capacity is 107.48 mg/g. It could be deso...The polytetrafluoroethylene fiber grafted acrylic acid was used as a cation exchanger. The exchange capacity of the cation fiber is 3.06 mmol/g. The maximum Cu2+ adsorption capacity is 107.48 mg/g. It could be desorbed completely by 1mol/L HCl.展开更多
Electroless nickel (copper)-phosphorus-silicon carbide (SiC)-polytetrafluoroethylene (PTFE) composite coatings were prepared by adding SiC and PTFE into electroless nickel (copper)-phosphorus alloy baths. The effects ...Electroless nickel (copper)-phosphorus-silicon carbide (SiC)-polytetrafluoroethylene (PTFE) composite coatings were prepared by adding SiC and PTFE into electroless nickel (copper)-phosphorus alloy baths. The effects of addition of SiC and PTFE on depositing rate, microhardness, wear resistance and anti-friction of the resulted composite coatings were studied. The results indicated that electroless nickel (copper)-phosphorus alloy coatings were greatly improved in depositing rate, microhardness, wear resistance and antifriction by co-deposited proper amount of SiC and PTFE.展开更多
The simultaneous γ-ray-radiation-induced grafting polymerization of acrylic acid on ex- panded polytetrafluoroethylene (ePTFE) film was investigated. It was found that the degree of grafting (DG) of poly(acrylic...The simultaneous γ-ray-radiation-induced grafting polymerization of acrylic acid on ex- panded polytetrafluoroethylene (ePTFE) film was investigated. It was found that the degree of grafting (DG) of poly(acrylic acid) (PAA) can be controlled by the monomer concentration, absorbed dose, and dose rate under an optimal inhibitor concentration of [Fe2+]=18 mmol/L. SEM observation showed that the macroporous structure in ePTFE films would be covered gradually with the increase of the DG of PAA. The prepared ePTFE-g-PAA film was im- mersed in a neutral silver nitrate solution to fabricate an ePTFE-g-PAA/Ag hybrid film after the addition of NaBH4 as a reduction agent of Ag+ to Ag atom. SEM, XRD, and XPS results proved that Ag nanoparticles with a size of several tens of nanometers to 100 nanometers were in situ immobilized on ePTFE film. The loading capacity of Ag nanoparticles could be tuned by the DG of PAA, and determined by thermal gravimetric analysis. The quart- titative antibacterial activity of the obtained ePTFE-g-PAA/Ag hybrid films was measured using counting plate method. It can kill all the Escherichia coli in the suspension in 1 h. Moreover, this excellent antibacterial activity can last at least for 4 h. This work provides a facile and practical way to make ePTFE meet the demanding antimicrobial requirement in more and more practical application areas.展开更多
In order to study the mechanical properties of modified low-density polytetrafluoroethylene (PTFE), universal testing machine is used for quasi-static tension and compression tests and Hopkinson bar test is for mech...In order to study the mechanical properties of modified low-density polytetrafluoroethylene (PTFE), universal testing machine is used for quasi-static tension and compression tests and Hopkinson bar test is for mechanical property under impact load. The mechanical properties of the samples with different length-diameter ratios under different impact loads are analyzed and dynamic response characteristics of the modified PTFE at different impact speeds are studied. The results show that, adding the copper powder in PTFE material can increase not only the tensile strength and elongation of the PTFE material sig- nificantly, but also the compressive strength; with the increase of strain rate, the yield strength of modified PTFE increases.展开更多
Polytetrafluoroethylene (Teflon), a widely used spacecraft material, isstudied to investigate the vacuum ultraviolet (VUV) effects and its synergistic effects with atomicoxygen (AO) in a ground-based simulation facili...Polytetrafluoroethylene (Teflon), a widely used spacecraft material, isstudied to investigate the vacuum ultraviolet (VUV) effects and its synergistic effects with atomicoxygen (AO) in a ground-based simulation facility. The samples before and after the experiments arecompared in appearance, mass, optical properties and surface composition. The reactioncharacteristics of Teflon are summarized and the reaction mechanisms are analyzed. The followingconclusion can be drawn: at the action of VUV the Teflon sample surface is darkened for theaccumulation of carbon; and when the sample is exposed to AO, the carbon is oxidized and thedarkening surface is bleached; the synergistic effects of VUV and AO may cause the erosion of Teflonmore severe.展开更多
Polymer-based composite was investigated by embedding calcium copper titanate(CaCu_3Ti_4O_(12); CCTO) fillers into polytetrafluoroethylene(PTFE) matrix. The dielectric performances of the composite were investigated w...Polymer-based composite was investigated by embedding calcium copper titanate(CaCu_3Ti_4O_(12); CCTO) fillers into polytetrafluoroethylene(PTFE) matrix. The dielectric performances of the composite were investigated within the frequency range from 100 Hz to 1 MHz. It is indicated that dielectric permittivity(ε) and dielectric loss(tanδ) increase gradually as the filler content increases. Dielectric permittivity for the composite with 50 vol% CCTO filler loading is 33.5, approximately 16 times higher than that of pure PTFE(ε = 2.1) at 100 Hz. As the frequency increases, the dielectric loss decreases rapidly and reaches stability, and then remains low when the frequency rises to 1 MHz. The values for dielectric permittivity and dielectric loss in the microwave frequency(8-13 GHz) are lower than that in low frequency of 10 kHz for the composites because of different polarization modes. Several theoretical models were implemented to compare the experimental results with the theoretical calculations and the modified Lichtenecker equation was found to fit the best.展开更多
Bilirubin removal from human plasma was obtained via an affinity microporous polytetrafluoroethylene(MPTFE) capillary. The new adsorbent comprised grafted glycidyl methacrylate(GMA) via radiation-induced polymeriz...Bilirubin removal from human plasma was obtained via an affinity microporous polytetrafluoroethylene(MPTFE) capillary. The new adsorbent comprised grafted glycidyl methacrylate(GMA) via radiation-induced polymerization as hydrophilic coating and reactive sites; ethylenediamine(EDA) as a spacer arm; Cibacron Blue F3GA(CB F3GA) as an affinity ligand; MPTFE capillary as the supporting matrix. The average density of CB F3GA attachment to MPTFE capillaries was found to be 136.5 μmol/g. The capacity of bilirubin adsorbed on affinity MPTFE capillaries is 76.1 mg bilirubin/g polymer(at 25℃). This new adsorbent has advantages over both membrane and traditional micro-column, and this system is stable and easy to operate. The results of blood tests suggest the CB F3GA affinity capillary has good blood compatibility.展开更多
文摘The polytetrafluoroethylene fiber grafted acrylic acid was used as a cation exchanger. The exchange capacity of the cation fiber is 3.06 mmol/g. The maximum Cu2+ adsorption capacity is 107.48 mg/g. It could be desorbed completely by 1mol/L HCl.
文摘Electroless nickel (copper)-phosphorus-silicon carbide (SiC)-polytetrafluoroethylene (PTFE) composite coatings were prepared by adding SiC and PTFE into electroless nickel (copper)-phosphorus alloy baths. The effects of addition of SiC and PTFE on depositing rate, microhardness, wear resistance and anti-friction of the resulted composite coatings were studied. The results indicated that electroless nickel (copper)-phosphorus alloy coatings were greatly improved in depositing rate, microhardness, wear resistance and antifriction by co-deposited proper amount of SiC and PTFE.
文摘The simultaneous γ-ray-radiation-induced grafting polymerization of acrylic acid on ex- panded polytetrafluoroethylene (ePTFE) film was investigated. It was found that the degree of grafting (DG) of poly(acrylic acid) (PAA) can be controlled by the monomer concentration, absorbed dose, and dose rate under an optimal inhibitor concentration of [Fe2+]=18 mmol/L. SEM observation showed that the macroporous structure in ePTFE films would be covered gradually with the increase of the DG of PAA. The prepared ePTFE-g-PAA film was im- mersed in a neutral silver nitrate solution to fabricate an ePTFE-g-PAA/Ag hybrid film after the addition of NaBH4 as a reduction agent of Ag+ to Ag atom. SEM, XRD, and XPS results proved that Ag nanoparticles with a size of several tens of nanometers to 100 nanometers were in situ immobilized on ePTFE film. The loading capacity of Ag nanoparticles could be tuned by the DG of PAA, and determined by thermal gravimetric analysis. The quart- titative antibacterial activity of the obtained ePTFE-g-PAA/Ag hybrid films was measured using counting plate method. It can kill all the Escherichia coli in the suspension in 1 h. Moreover, this excellent antibacterial activity can last at least for 4 h. This work provides a facile and practical way to make ePTFE meet the demanding antimicrobial requirement in more and more practical application areas.
基金Graduate Education Innovation Project of Shanxi Province(No.2015SY59)
文摘In order to study the mechanical properties of modified low-density polytetrafluoroethylene (PTFE), universal testing machine is used for quasi-static tension and compression tests and Hopkinson bar test is for mechanical property under impact load. The mechanical properties of the samples with different length-diameter ratios under different impact loads are analyzed and dynamic response characteristics of the modified PTFE at different impact speeds are studied. The results show that, adding the copper powder in PTFE material can increase not only the tensile strength and elongation of the PTFE material sig- nificantly, but also the compressive strength; with the increase of strain rate, the yield strength of modified PTFE increases.
文摘Polytetrafluoroethylene (Teflon), a widely used spacecraft material, isstudied to investigate the vacuum ultraviolet (VUV) effects and its synergistic effects with atomicoxygen (AO) in a ground-based simulation facility. The samples before and after the experiments arecompared in appearance, mass, optical properties and surface composition. The reactioncharacteristics of Teflon are summarized and the reaction mechanisms are analyzed. The followingconclusion can be drawn: at the action of VUV the Teflon sample surface is darkened for theaccumulation of carbon; and when the sample is exposed to AO, the carbon is oxidized and thedarkening surface is bleached; the synergistic effects of VUV and AO may cause the erosion of Teflonmore severe.
基金Funded by the National Natural Science Foundation of China(No.61172004)the Fundamental Research Funds for the Central Universities(No.2017KFYXJJ022)
文摘Polymer-based composite was investigated by embedding calcium copper titanate(CaCu_3Ti_4O_(12); CCTO) fillers into polytetrafluoroethylene(PTFE) matrix. The dielectric performances of the composite were investigated within the frequency range from 100 Hz to 1 MHz. It is indicated that dielectric permittivity(ε) and dielectric loss(tanδ) increase gradually as the filler content increases. Dielectric permittivity for the composite with 50 vol% CCTO filler loading is 33.5, approximately 16 times higher than that of pure PTFE(ε = 2.1) at 100 Hz. As the frequency increases, the dielectric loss decreases rapidly and reaches stability, and then remains low when the frequency rises to 1 MHz. The values for dielectric permittivity and dielectric loss in the microwave frequency(8-13 GHz) are lower than that in low frequency of 10 kHz for the composites because of different polarization modes. Several theoretical models were implemented to compare the experimental results with the theoretical calculations and the modified Lichtenecker equation was found to fit the best.
基金Supported by the National Natural Science Foundation of China(No.29405038)
文摘Bilirubin removal from human plasma was obtained via an affinity microporous polytetrafluoroethylene(MPTFE) capillary. The new adsorbent comprised grafted glycidyl methacrylate(GMA) via radiation-induced polymerization as hydrophilic coating and reactive sites; ethylenediamine(EDA) as a spacer arm; Cibacron Blue F3GA(CB F3GA) as an affinity ligand; MPTFE capillary as the supporting matrix. The average density of CB F3GA attachment to MPTFE capillaries was found to be 136.5 μmol/g. The capacity of bilirubin adsorbed on affinity MPTFE capillaries is 76.1 mg bilirubin/g polymer(at 25℃). This new adsorbent has advantages over both membrane and traditional micro-column, and this system is stable and easy to operate. The results of blood tests suggest the CB F3GA affinity capillary has good blood compatibility.