4H-SiC single photon counting avalanche photodiodes(SPADs)are prior devices for weak ultraviolet(UV)signal detection with the advantages of small size,low leakage current,high avalanche multiplication gain,and high qu...4H-SiC single photon counting avalanche photodiodes(SPADs)are prior devices for weak ultraviolet(UV)signal detection with the advantages of small size,low leakage current,high avalanche multiplication gain,and high quantum efficiency,which benefit from the large bandgap energy,high carrier drift velocity and excellent physical stability of 4 H-SiC semiconductor material.UV detectors are widely used in many key applications,such as missile plume detection,corona discharge,UV astronomy,and biological and chemical agent detection.In this paper,we will describe basic concepts and review recent results on device design,process development,and basic characterizations of 4 H-SiC avalanche photodiodes.Several promising device structures and uniformity of avalanche multiplication are discussed,which are important for achieving high performance of 4 HSiC UV SPADs.展开更多
A signal chain model of single-bit and multi-bit quanta image sensors(QISs)is established.Based on the proposed model,the photoresponse characteristics and signal error rates of QISs are investigated,and the effects o...A signal chain model of single-bit and multi-bit quanta image sensors(QISs)is established.Based on the proposed model,the photoresponse characteristics and signal error rates of QISs are investigated,and the effects of bit depth,quantum efficiency,dark current,and read noise on them are analyzed.When the signal error rates towards photons and photoelectrons counting are lower than 0.01,the high accuracy photon and photoelectron counting exposure ranges are determined.Furthermore,an optimization method of integration time to ensure that the QIS works in these high accuracy exposure ranges is presented.The trade-offs between pixel area,the mean value of incident photons,and integration time under different illuminance level are analyzed.For the 3-bit QIS with 0.16 e-/s dark current and 0.21 e-r.m.s.read noise,when the illuminance level and pixel area are 1 lux and 1.21μm^(2),or 10000 lux and 0.21μm^(2),the recommended integration time is 8.8 to 30 ms,or 10 to21.3μs,respectively.The proposed method can guide the design and operation of single-bit and multi-bit QISs.展开更多
A true random coded photon counting Lidar system is proposed in this paper,in which a single photon detector acts as the true random sequence signal generator instead of the traditional function generator.Compared wit...A true random coded photon counting Lidar system is proposed in this paper,in which a single photon detector acts as the true random sequence signal generator instead of the traditional function generator.Compared with the traditional pseudo-random coded method,the true random coded method not only improves the anti-crosstalk capability of the system,but more importantly,it effectively overcomes the adverse effect of the detector’s dead time on the ranging performance.The experiment results show that the ranging performance of the true random coded method is obviously better than that of the pseudo-random coded method.As a result,a three-dimensional scanning imaging of a model car is completed by the true random coded method.展开更多
By virtue of the density operator's P-representation in the coherent state representation, we derive a new quantum mechanical photon counting distribution formula. As its application, we calculate photon counting dis...By virtue of the density operator's P-representation in the coherent state representation, we derive a new quantum mechanical photon counting distribution formula. As its application, we calculate photon counting distributions for some given light fields. It is found that the pure squeezed state's photon counting distribution is related to the Legendre function, which is a new result.展开更多
Geiger mode avalanche photodiode detector (Gm-APD) possesses the ultra-high sensitivity. Photon counting chirped amplitude modulation (PCCAM) light detection and ranging (lidar) uses the counting results of the ...Geiger mode avalanche photodiode detector (Gm-APD) possesses the ultra-high sensitivity. Photon counting chirped amplitude modulation (PCCAM) light detection and ranging (lidar) uses the counting results of the returned signal detected by Gm-APD to mix with the reference signal, which makes PCCAM lidar capable of realizing the ultra-high sensitivity, and this is very important for detecting the remote and weak signal. However, Gm-APD is a nonlinear device, different from traditional linear detectors. Due to the nonlinear response of Gm-APD, the counting results of the returned signal detected by Gm-APD are different from those of both the original modulation signal and the reference signal. This will affect the mixing effect and thus degrade the detection performance of PCCAM lidar. In this paper, we propose a response probability correction method. First, the response probability correction model is established on the basis of Gm-APD Poisson prob- ability response model. Then, the response probability correction model is used to adjust the original modulation signal that is used to drive laser, in order to make the counting results of the returned signal detected by Gm-APD better mix with the local reference signal in the same form. Through this method, the detection performance of PCCAM lidar is enhanced efficiently.展开更多
By virtue of the neat expression of the two-mode squeezing operator in the Einstein, Podolsky and Rosen entangled state representation, we provide a new approach for discussing the teleportation scheme using optical s...By virtue of the neat expression of the two-mode squeezing operator in the Einstein, Podolsky and Rosen entangled state representation, we provide a new approach for discussing the teleportation scheme using optical squeezers and photon counting devices. We derive the explicit form of the teleported states, so that the conditional property of teleportation and teleportation fidelity of this protocol can be seen more clearly. The derivation is concise.展开更多
Single-photon detectors possess the ultra-high sensitivity, but they cannot directly respond to signal intensity. Conven- tional methods adopt sampling gates with fixed width and count the triggered number of sampling...Single-photon detectors possess the ultra-high sensitivity, but they cannot directly respond to signal intensity. Conven- tional methods adopt sampling gates with fixed width and count the triggered number of sampling gates, which is capable of obtaining photon counting probability to estimate the echo signal intensity. In this paper, we not only count the number of triggered sampling gates, but also record the triggered time position of photon counting pulses. The photon counting probability density distribution is obtained through the statistics of a series of the triggered time positions. Then Minimum Variance Unbiased Estimation (MVUE) method is used to estimate the echo signal intensity. Compared with conventional methods, this method can improve the estimation accuracy of echo signal intensity due to the acquisition of more detected information. Finally, a proof-of-principle laboratory system is established. The estimation accuracy of echo signal intensity is discussed and a high accuracy intensity image is acquired under low-light level environments.展开更多
We investigate the influence of the field fluctuations to the emission photons of V-type three-level systems.The emission intensity I and Mandel's Q parameter show stochastic resonance with respect to the pure dephas...We investigate the influence of the field fluctuations to the emission photons of V-type three-level systems.The emission intensity I and Mandel's Q parameter show stochastic resonance with respect to the pure dephasing constantγp.The amplitude fluctuation of the field causes these systems to lose their coherence.On the other hand,the amplitude fluctuation provides a new interference method for these systems.The quantum beats are shown in the orthogonal system.展开更多
A novel FPGA-based pulse pile-up rejection method for single photon imaging detectors is reported. Tile method is easy to implement in FPGAs for real-time data processing. The rejection principle and entire design are...A novel FPGA-based pulse pile-up rejection method for single photon imaging detectors is reported. Tile method is easy to implement in FPGAs for real-time data processing. The rejection principle and entire design are introduced in detail. The photon counting imaging detector comprises a micro-channel plate (MCP) stack, and a wedge and strip anode (WSA). The resolution mask pattern in front of the MCP can be reconstructed after data processing in the FPGA. For high count rates, the rejection design can effectively reduce the impact of the pulse pile-up on the image. The resolution can reach up to 140μm. The pulse pile-up rejection design can also be applied to high-energy physics and particle detection.展开更多
X-ray charge-coupled-device(CCD) camera working in single photon counting mode is a type of x-ray spectrometer with high-sensitivity and superior signal-to-noise performance. In this study, two single photon countin...X-ray charge-coupled-device(CCD) camera working in single photon counting mode is a type of x-ray spectrometer with high-sensitivity and superior signal-to-noise performance. In this study, two single photon counting CCD cameras with the same mode(model: PI-LCX: 1300) are calibrated with quasi-monochromatic x-rays from radioactive sources and a conventional x-ray tube. The details of the CCD response to x-rays are analyzed by using a computer program of multi-pixel analyzing and event-distinguishing capability. The detection efficiency, energy resolution, fraction of multi-pixel events each as a function of x-ray energy, and consistence of two CCD cameras are obtained. The calibrated detection efficiency is consistent with the detection efficiency from Monte Carlo calculations with XOP program. When the multi-pixel event analysis is applied, the CCDs may be used to measure x-rays up to 60 ke V with good energy resolution(E /?E ≈ 100 at60 ke V). The difference in detection efficiency between two CCD cameras is small(5.6% at 5.89 ke V), but the difference in fraction of the single pixel event between them is much larger(25% at 8.04 ke V). The obtained small relative error of detection efficiency(2.4% at 5.89 ke V) makes the high accurate measurement of x-ray yield possible in the laser plasma interaction studies. Based on the discrete calibration results, the calculated detection efficiency with XOP can be used for the whole range of 5 ke V–30 ke V.展开更多
Photon counting detectors(PCDs) have attained w ide use in X-ray imaging for various preclinical and clinical applications in the past decade. This paper briefly review s the preclinical and clinical applications of P...Photon counting detectors(PCDs) have attained w ide use in X-ray imaging for various preclinical and clinical applications in the past decade. This paper briefly review s the preclinical and clinical applications of PCDs based X-ray imaging systems.Starting with an introduction of X-ray single photon detection mechanism,the brief review first describes tw o major advantages of utilizing PCDs: photon energy resolving capability and electronic noise elimination. Compared to energy integrating detectors(EIDs),the aforementioned advantages make PCDs more favorable in X-ray imaging with profound benefits such as enhanced tissue contrast,decreased image noise,increased signal to noise ratio,decreased radiation dose to the small animals and patients,and more accurate material decomposition. The utilizations of PCDs in X-ray projection radiography and computed tomography(CT)including micro-CT,dedicated breast CT,K-edge CT,and clinical CT are then review ed for the imaging applications ranging from phantoms to small animals and humans. In addition,optimization methods aiming to improve the imaging performance using PCDs are briefly review ed. PCDs are not flaw less though,and their limitations are also discussed in this review. Nevertheless,PCDs may continuously contribute to the advancement of X-ray imaging techniques in future preclinical and clinical applications.展开更多
The first photon bias of photon detection results in distortion of the photon waveform,which seriously affects the accurate acquisition of target information.A rapid universal recursive correction method is proposed,w...The first photon bias of photon detection results in distortion of the photon waveform,which seriously affects the accurate acquisition of target information.A rapid universal recursive correction method is proposed,which is suitable for multi-trigger and single-trigger modes of photon detection.The calculation time is 2 to 3 orders of magnitude faster than that of Xu et al.'s method.In the experiment,we have obtained good correction results for area targets and targets with varying depths.When the average number of echo photons is 0.89,the correlation distance of the correction waveform is reduced by 85%.展开更多
High speed pseudorandom modulation and photon counting techniques are applied to a three-dimensional imaging lidar system.The specific structure and working principle of the lidar system is described.The actual detect...High speed pseudorandom modulation and photon counting techniques are applied to a three-dimensional imaging lidar system.The specific structure and working principle of the lidar system is described.The actual detector efficiency of a single-photon detector in an imaging system is discussed,and the result shows that a variety of reasons lead to the decrease in detection efficiency.A series of ranging and imaging experiments are conducted,and a series of high-resolution three-dimensional images and a distance value of 1200 m of noncooperative targets are acquired.展开更多
A two-dimensional photon counting imaging detector based on a Vernier position sensitive anode is reported. The decode principle and design of a two-dimensional Vernier anode are introduced in detail. A photon countin...A two-dimensional photon counting imaging detector based on a Vernier position sensitive anode is reported. The decode principle and design of a two-dimensional Vernier anode are introduced in detail. A photon counting imaging system was built based on a Vernier anode. The image of very weak optical radiation can be reconstructed by image processing in a period of integration time. The resolution is superior to 100 μm according to the resolution test. The detector may realize the imaging of very weak particle flow of highenergy photons, electrons and ions, so it can be used for high-energy physics, deep space exploration, spectral measurement and bio-luminescence detection.展开更多
The decoding algorithms of two-dimensional Vernier anodes are deduced theoretically.The precision of decoding and uniqueness of encoding are proved.The influencing factors of detection sensitivity and spatial resoluti...The decoding algorithms of two-dimensional Vernier anodes are deduced theoretically.The precision of decoding and uniqueness of encoding are proved.The influencing factors of detection sensitivity and spatial resolution are discussed.The single photon imaging system is constructed,and the two-dimensional Vernier collector is fabricated.The image of the ultra-weak emission source is reconstructed.The spatial resolution of the system is about 100μm.展开更多
Photon-counting LiDAR using a two-dimensional(2D)array detector has the advantages of high lateral resolution and fast acquisition speed.The non-uniform intensity profile of the illumination beam and non-uniform quant...Photon-counting LiDAR using a two-dimensional(2D)array detector has the advantages of high lateral resolution and fast acquisition speed.The non-uniform intensity profile of the illumination beam and non-uniform quantum efficiency of the detectors in the 2D array deteriorate the imaging quality.Herein,we propose a photon-counting LiDAR system that uses a spatial light modulator to control the spatial intensity to compensate for both the non-uniform intensity profile of the illumination beam,and the variation in the quantum efficiency of the detectors in the 2D array.By using a 635 nm peak wavelength and 4 mW average power semiconductor laser,lab-based experiments at a 4.27 m stand-off distance are performed to verify the effectiveness of the proposed method.Compared with the unmodulated method,the standard deviation of the intensity image of the proposed method is reduced from 0.109 to 0.089 for a whiteboard target,with an average signal photon number of 0.006 per pixel.展开更多
We demonstrate a photon-counting chirped amplitude modulation (CAM) light detection and ranging (lidar) system incorporating a superconducting nanowire single-photon detector (SNSPD) and operated at a wavelength...We demonstrate a photon-counting chirped amplitude modulation (CAM) light detection and ranging (lidar) system incorporating a superconducting nanowire single-photon detector (SNSPD) and operated at a wavelength of 1550 nm. The distance accuracy of the lidar system was determined by the CAM bandwidth and signal-to-noise ratio (SNR) of an intermediate frequency (IF) signal. Owing to a short dead time (10 ns) and negligible dark count rate (70 Hz) of the SNSPD, the obtained IF signal attained an SNR of 42 dB and the direct distance accuracy was improved to 3 mm when the modulation bandwidth of the CAM signal was 240 MHz and the modulation period was 1 ms.展开更多
Purpose K-edge imaging based on the photon counting detectors(PCDs)is an effective enhanced imaging method because the PCDs are conducive to the K-edge imaging due to the adjustable energy thresholds.The energy bins s...Purpose K-edge imaging based on the photon counting detectors(PCDs)is an effective enhanced imaging method because the PCDs are conducive to the K-edge imaging due to the adjustable energy thresholds.The energy bins significantly affect the image quality of the K-edge imaging,but the conventional energy bins used for K-edge imaging are continuous which weaken the K-edge signal and decline the image quality.Hence,how to get a better K-edge signal by the optimized energy bins is the key point for the K-edge imaging based on the PCDs.Method This paper experimentally studied the influence of the energy bins used for the K-edge imaging based on the PCDs.The conventional energy bins were determined by the theoretical-attenuation method(TAM),and the optimized energy bins were determined by the threshold-scan method(TSM).For the phantom and mice imaging,we performed both the K-edge subtraction algorithm and the K-edge decomposition algorithm on the projections obtained by the energy bins which were determined by the TAM and TSM.The image quality was compared using the CNR of the objective area.Results The experimental results showed that the energy bins identified by the TSM had a better performance than the TAM in both imaging methods.The TSM improved the CNR by~39%than the TAM in the phantom results and could better highlight the areas where the contrast agents are enriched(such as the kidney).Conclusions The optimized energy bins can better highlight the K-edge signal than the conventional energy bins which can improve the image quality and have the potential to reduce the amount of the contrast agents.展开更多
In this Letter, we propose a novel three-dimeusional (3D) color microscopy for microorganisms under photon- starved conditions using photon counting integral imaging and Bayesian estimation with adaptive priori info...In this Letter, we propose a novel three-dimeusional (3D) color microscopy for microorganisms under photon- starved conditions using photon counting integral imaging and Bayesian estimation with adaptive priori infor- mation. In photon counting integral imaging, 3D images can be visualized using maximum likelihood estimation (MLE). However, since MLE does not consider a priori information of objects, the visual quality of 3D images may not be accurate. In addition, the only grayscale image can be reconstructed. Therefore, to enhance the visual quality of 3D images, we propose photon counting microscopy using maximum a posteriori with adaptive priori information. In addition, we consider a wavelength of each basic color channel to reconstruct 3D color images. To verify our proposed method, we carry out optical experiments.展开更多
The Cramer–Rao lower bound on range error is modeled for pseudo-random ranging systems using Geiger-mode avalanche photodiodes. The theoretical results are shown to agree with the Monte Carlo simulation, satisfying b...The Cramer–Rao lower bound on range error is modeled for pseudo-random ranging systems using Geiger-mode avalanche photodiodes. The theoretical results are shown to agree with the Monte Carlo simulation, satisfying boundary evaluations. Experimental tests prove that range errors caused by the fluctuation of the number of photon counts in the laser echo pulse leads to the range drift of the time point spread function. The function relationship between the range error and the photon counting ratio is determined by using numerical fitting.Range errors due to a different echo energy is calibrated so that the corrected range root mean square error is improved to 1 cm.展开更多
基金supported in part by National Key R&D Program of China under Grant No. 2016YFB0400902in part by the Priority Academic Program Development of Jiangsu Higher Education Institutions
文摘4H-SiC single photon counting avalanche photodiodes(SPADs)are prior devices for weak ultraviolet(UV)signal detection with the advantages of small size,low leakage current,high avalanche multiplication gain,and high quantum efficiency,which benefit from the large bandgap energy,high carrier drift velocity and excellent physical stability of 4 H-SiC semiconductor material.UV detectors are widely used in many key applications,such as missile plume detection,corona discharge,UV astronomy,and biological and chemical agent detection.In this paper,we will describe basic concepts and review recent results on device design,process development,and basic characterizations of 4 H-SiC avalanche photodiodes.Several promising device structures and uniformity of avalanche multiplication are discussed,which are important for achieving high performance of 4 HSiC UV SPADs.
基金supported by the Tianjin Key Laboratory of Imaging and Sensing Microelectronic Technology。
文摘A signal chain model of single-bit and multi-bit quanta image sensors(QISs)is established.Based on the proposed model,the photoresponse characteristics and signal error rates of QISs are investigated,and the effects of bit depth,quantum efficiency,dark current,and read noise on them are analyzed.When the signal error rates towards photons and photoelectrons counting are lower than 0.01,the high accuracy photon and photoelectron counting exposure ranges are determined.Furthermore,an optimization method of integration time to ensure that the QIS works in these high accuracy exposure ranges is presented.The trade-offs between pixel area,the mean value of incident photons,and integration time under different illuminance level are analyzed.For the 3-bit QIS with 0.16 e-/s dark current and 0.21 e-r.m.s.read noise,when the illuminance level and pixel area are 1 lux and 1.21μm^(2),or 10000 lux and 0.21μm^(2),the recommended integration time is 8.8 to 30 ms,or 10 to21.3μs,respectively.The proposed method can guide the design and operation of single-bit and multi-bit QISs.
基金This work was supported by the National Natural Science Foundation of China(NSFC)(61805249)the Youth Innovation Promotion Association CAS(2019369).
文摘A true random coded photon counting Lidar system is proposed in this paper,in which a single photon detector acts as the true random sequence signal generator instead of the traditional function generator.Compared with the traditional pseudo-random coded method,the true random coded method not only improves the anti-crosstalk capability of the system,but more importantly,it effectively overcomes the adverse effect of the detector’s dead time on the ranging performance.The experiment results show that the ranging performance of the true random coded method is obviously better than that of the pseudo-random coded method.As a result,a three-dimensional scanning imaging of a model car is completed by the true random coded method.
基金supported by the National Natural Science Foundation of China(Grant Nos.11174114 and 11175113)the Research Foundation of Changzhou Institute of Technology,China(Grant No.YN1007)the Research Foundation of Education Department of Jiangxi Province,China(Grant No.GJJ10097)
文摘By virtue of the density operator's P-representation in the coherent state representation, we derive a new quantum mechanical photon counting distribution formula. As its application, we calculate photon counting distributions for some given light fields. It is found that the pure squeezed state's photon counting distribution is related to the Legendre function, which is a new result.
基金Project supported by the Fundamental Research Funds for the National Defense Basic Scientific Research,China(Grant No.JCKY2016603C007)
文摘Geiger mode avalanche photodiode detector (Gm-APD) possesses the ultra-high sensitivity. Photon counting chirped amplitude modulation (PCCAM) light detection and ranging (lidar) uses the counting results of the returned signal detected by Gm-APD to mix with the reference signal, which makes PCCAM lidar capable of realizing the ultra-high sensitivity, and this is very important for detecting the remote and weak signal. However, Gm-APD is a nonlinear device, different from traditional linear detectors. Due to the nonlinear response of Gm-APD, the counting results of the returned signal detected by Gm-APD are different from those of both the original modulation signal and the reference signal. This will affect the mixing effect and thus degrade the detection performance of PCCAM lidar. In this paper, we propose a response probability correction method. First, the response probability correction model is established on the basis of Gm-APD Poisson prob- ability response model. Then, the response probability correction model is used to adjust the original modulation signal that is used to drive laser, in order to make the counting results of the returned signal detected by Gm-APD better mix with the local reference signal in the same form. Through this method, the detection performance of PCCAM lidar is enhanced efficiently.
基金the President Foundation of the Chinese Academy of Sciences,National Natural Science Foundation of China
文摘By virtue of the neat expression of the two-mode squeezing operator in the Einstein, Podolsky and Rosen entangled state representation, we provide a new approach for discussing the teleportation scheme using optical squeezers and photon counting devices. We derive the explicit form of the teleported states, so that the conditional property of teleportation and teleportation fidelity of this protocol can be seen more clearly. The derivation is concise.
基金supported by the Fundamental Research Funds for the Central Universities,China(Grant No.AUGA5710056414)the Program for Innovation Research of Science in Harbin Institute of Technology(Grant Nos.PIRS OF HIT A201412 and PIRS OF HIT Q201505)+3 种基金the National Natural Science Foundation of China(Grant No.11675046)the Doctoral Fund of the Ministry of Education of China(Grant No.20122302120003)the Natural Science Foundation of Heilongjiang Province of China(Grant No.A201303)the Postdoctoral Scientific Research Developmental Fund of Heilongjiang Province,China(Grant No.LBH-Q15060)
文摘Single-photon detectors possess the ultra-high sensitivity, but they cannot directly respond to signal intensity. Conven- tional methods adopt sampling gates with fixed width and count the triggered number of sampling gates, which is capable of obtaining photon counting probability to estimate the echo signal intensity. In this paper, we not only count the number of triggered sampling gates, but also record the triggered time position of photon counting pulses. The photon counting probability density distribution is obtained through the statistics of a series of the triggered time positions. Then Minimum Variance Unbiased Estimation (MVUE) method is used to estimate the echo signal intensity. Compared with conventional methods, this method can improve the estimation accuracy of echo signal intensity due to the acquisition of more detected information. Finally, a proof-of-principle laboratory system is established. The estimation accuracy of echo signal intensity is discussed and a high accuracy intensity image is acquired under low-light level environments.
基金supported by the National Natural Science Foundation of China(Grand Nos.91021009,21073110,and 11374191)the Natural Science Foundation of Shandong Province,China(Grant No.ZR2013AQ020)+1 种基金the Postdoctoral Science Foundation of China(Grant No.2013M531584)the Doctoral Program of Higher Education of China(Grant Nos.20130131110005 and 20130131120006)
文摘We investigate the influence of the field fluctuations to the emission photons of V-type three-level systems.The emission intensity I and Mandel's Q parameter show stochastic resonance with respect to the pure dephasing constantγp.The amplitude fluctuation of the field causes these systems to lose their coherence.On the other hand,the amplitude fluctuation provides a new interference method for these systems.The quantum beats are shown in the orthogonal system.
基金Supported by the National Natural Science Foundation of China under Grant No 11375179
文摘A novel FPGA-based pulse pile-up rejection method for single photon imaging detectors is reported. Tile method is easy to implement in FPGAs for real-time data processing. The rejection principle and entire design are introduced in detail. The photon counting imaging detector comprises a micro-channel plate (MCP) stack, and a wedge and strip anode (WSA). The resolution mask pattern in front of the MCP can be reconstructed after data processing in the FPGA. For high count rates, the rejection design can effectively reduce the impact of the pulse pile-up on the image. The resolution can reach up to 140μm. The pulse pile-up rejection design can also be applied to high-energy physics and particle detection.
基金Project supported by the Science Foundation of China Academy of Engineering Physics(Grant Nos.2013A0103003 and 2012B0102008)the National High-Tech Inertial Confinement Fusion Committee of China
文摘X-ray charge-coupled-device(CCD) camera working in single photon counting mode is a type of x-ray spectrometer with high-sensitivity and superior signal-to-noise performance. In this study, two single photon counting CCD cameras with the same mode(model: PI-LCX: 1300) are calibrated with quasi-monochromatic x-rays from radioactive sources and a conventional x-ray tube. The details of the CCD response to x-rays are analyzed by using a computer program of multi-pixel analyzing and event-distinguishing capability. The detection efficiency, energy resolution, fraction of multi-pixel events each as a function of x-ray energy, and consistence of two CCD cameras are obtained. The calibrated detection efficiency is consistent with the detection efficiency from Monte Carlo calculations with XOP program. When the multi-pixel event analysis is applied, the CCDs may be used to measure x-rays up to 60 ke V with good energy resolution(E /?E ≈ 100 at60 ke V). The difference in detection efficiency between two CCD cameras is small(5.6% at 5.89 ke V), but the difference in fraction of the single pixel event between them is much larger(25% at 8.04 ke V). The obtained small relative error of detection efficiency(2.4% at 5.89 ke V) makes the high accurate measurement of x-ray yield possible in the laser plasma interaction studies. Based on the discrete calibration results, the calculated detection efficiency with XOP can be used for the whole range of 5 ke V–30 ke V.
基金supported in part by a grant from the University of Oklahoma Charles and Peggy Stephenson Cancer Center funded by the Oklahoma Tobacco Settlement Endowment Trust
文摘Photon counting detectors(PCDs) have attained w ide use in X-ray imaging for various preclinical and clinical applications in the past decade. This paper briefly review s the preclinical and clinical applications of PCDs based X-ray imaging systems.Starting with an introduction of X-ray single photon detection mechanism,the brief review first describes tw o major advantages of utilizing PCDs: photon energy resolving capability and electronic noise elimination. Compared to energy integrating detectors(EIDs),the aforementioned advantages make PCDs more favorable in X-ray imaging with profound benefits such as enhanced tissue contrast,decreased image noise,increased signal to noise ratio,decreased radiation dose to the small animals and patients,and more accurate material decomposition. The utilizations of PCDs in X-ray projection radiography and computed tomography(CT)including micro-CT,dedicated breast CT,K-edge CT,and clinical CT are then review ed for the imaging applications ranging from phantoms to small animals and humans. In addition,optimization methods aiming to improve the imaging performance using PCDs are briefly review ed. PCDs are not flaw less though,and their limitations are also discussed in this review. Nevertheless,PCDs may continuously contribute to the advancement of X-ray imaging techniques in future preclinical and clinical applications.
基金the National Natural Science Foundation of China(No.61871389)the Research Plan Project of the National University ofDefense Technology(No.ZK 18-01-02)。
文摘The first photon bias of photon detection results in distortion of the photon waveform,which seriously affects the accurate acquisition of target information.A rapid universal recursive correction method is proposed,which is suitable for multi-trigger and single-trigger modes of photon detection.The calculation time is 2 to 3 orders of magnitude faster than that of Xu et al.'s method.In the experiment,we have obtained good correction results for area targets and targets with varying depths.When the average number of echo photons is 0.89,the correlation distance of the correction waveform is reduced by 85%.
基金supported by the Innovation Fund(No.CXJJ16M102)the National 973 Program of China (No.613192)
文摘High speed pseudorandom modulation and photon counting techniques are applied to a three-dimensional imaging lidar system.The specific structure and working principle of the lidar system is described.The actual detector efficiency of a single-photon detector in an imaging system is discussed,and the result shows that a variety of reasons lead to the decrease in detection efficiency.A series of ranging and imaging experiments are conducted,and a series of high-resolution three-dimensional images and a distance value of 1200 m of noncooperative targets are acquired.
基金Supported by Key Program of National Natural Science Foundation of China (10878005)
文摘A two-dimensional photon counting imaging detector based on a Vernier position sensitive anode is reported. The decode principle and design of a two-dimensional Vernier anode are introduced in detail. A photon counting imaging system was built based on a Vernier anode. The image of very weak optical radiation can be reconstructed by image processing in a period of integration time. The resolution is superior to 100 μm according to the resolution test. The detector may realize the imaging of very weak particle flow of highenergy photons, electrons and ions, so it can be used for high-energy physics, deep space exploration, spectral measurement and bio-luminescence detection.
基金supported by the National Natural Science Foundation of China (Grant No. 10878005/A03)
文摘The decoding algorithms of two-dimensional Vernier anodes are deduced theoretically.The precision of decoding and uniqueness of encoding are proved.The influencing factors of detection sensitivity and spatial resolution are discussed.The single photon imaging system is constructed,and the two-dimensional Vernier collector is fabricated.The image of the ultra-weak emission source is reconstructed.The spatial resolution of the system is about 100μm.
文摘Photon-counting LiDAR using a two-dimensional(2D)array detector has the advantages of high lateral resolution and fast acquisition speed.The non-uniform intensity profile of the illumination beam and non-uniform quantum efficiency of the detectors in the 2D array deteriorate the imaging quality.Herein,we propose a photon-counting LiDAR system that uses a spatial light modulator to control the spatial intensity to compensate for both the non-uniform intensity profile of the illumination beam,and the variation in the quantum efficiency of the detectors in the 2D array.By using a 635 nm peak wavelength and 4 mW average power semiconductor laser,lab-based experiments at a 4.27 m stand-off distance are performed to verify the effectiveness of the proposed method.Compared with the unmodulated method,the standard deviation of the intensity image of the proposed method is reduced from 0.109 to 0.089 for a whiteboard target,with an average signal photon number of 0.006 per pixel.
基金Project supported by National Key R&D Program of China(Grant No.2017YFA0304000)the National Natural Science Foundation of China(NSFC)(Grant Nos.61501442 and 61671438)the Joint Research Fund in Astronomy(U1631240)under Cooperative Agreement between the NSFC and Chinese Academy of Sciences(CAS)
文摘We demonstrate a photon-counting chirped amplitude modulation (CAM) light detection and ranging (lidar) system incorporating a superconducting nanowire single-photon detector (SNSPD) and operated at a wavelength of 1550 nm. The distance accuracy of the lidar system was determined by the CAM bandwidth and signal-to-noise ratio (SNR) of an intermediate frequency (IF) signal. Owing to a short dead time (10 ns) and negligible dark count rate (70 Hz) of the SNSPD, the obtained IF signal attained an SNR of 42 dB and the direct distance accuracy was improved to 3 mm when the modulation bandwidth of the CAM signal was 240 MHz and the modulation period was 1 ms.
基金supported by National Key R&D Program of China(Grant No.2016YFC0100400)Science and Tech-nology Service network Initiative of Chinese Academy of Sciences(Grant No.KFJ-STS-QYZD-193)+1 种基金Instrument Developing Project of Chinese Academy of Sciences(Grant No.YZ201511)National Natu-ral Science Foundation of China(Grant No.11975250)
文摘Purpose K-edge imaging based on the photon counting detectors(PCDs)is an effective enhanced imaging method because the PCDs are conducive to the K-edge imaging due to the adjustable energy thresholds.The energy bins significantly affect the image quality of the K-edge imaging,but the conventional energy bins used for K-edge imaging are continuous which weaken the K-edge signal and decline the image quality.Hence,how to get a better K-edge signal by the optimized energy bins is the key point for the K-edge imaging based on the PCDs.Method This paper experimentally studied the influence of the energy bins used for the K-edge imaging based on the PCDs.The conventional energy bins were determined by the theoretical-attenuation method(TAM),and the optimized energy bins were determined by the threshold-scan method(TSM).For the phantom and mice imaging,we performed both the K-edge subtraction algorithm and the K-edge decomposition algorithm on the projections obtained by the energy bins which were determined by the TAM and TSM.The image quality was compared using the CNR of the objective area.Results The experimental results showed that the energy bins identified by the TSM had a better performance than the TAM in both imaging methods.The TSM improved the CNR by~39%than the TAM in the phantom results and could better highlight the areas where the contrast agents are enriched(such as the kidney).Conclusions The optimized energy bins can better highlight the K-edge signal than the conventional energy bins which can improve the image quality and have the potential to reduce the amount of the contrast agents.
基金supported in part by Basic Science Research Program through the National Research Foundation of Korea(NRF)funded by the Ministry of Science,Information and Communications TechnologiesFuture Planning(No.2011-0030079)Basic Science Research Program through the NRF funded by the Ministry of Education(NRF-2013R1A1A2057549)
文摘In this Letter, we propose a novel three-dimeusional (3D) color microscopy for microorganisms under photon- starved conditions using photon counting integral imaging and Bayesian estimation with adaptive priori infor- mation. In photon counting integral imaging, 3D images can be visualized using maximum likelihood estimation (MLE). However, since MLE does not consider a priori information of objects, the visual quality of 3D images may not be accurate. In addition, the only grayscale image can be reconstructed. Therefore, to enhance the visual quality of 3D images, we propose photon counting microscopy using maximum a posteriori with adaptive priori information. In addition, we consider a wavelength of each basic color channel to reconstruct 3D color images. To verify our proposed method, we carry out optical experiments.
基金supported by the National Natural Science Foundation of China(Nos.61101196 and 61271332)the Natural Science Research Foundation of Jiangsu Province(No.168JB510015)
文摘The Cramer–Rao lower bound on range error is modeled for pseudo-random ranging systems using Geiger-mode avalanche photodiodes. The theoretical results are shown to agree with the Monte Carlo simulation, satisfying boundary evaluations. Experimental tests prove that range errors caused by the fluctuation of the number of photon counts in the laser echo pulse leads to the range drift of the time point spread function. The function relationship between the range error and the photon counting ratio is determined by using numerical fitting.Range errors due to a different echo energy is calibrated so that the corrected range root mean square error is improved to 1 cm.