As mask features scale to smaller dimensions, the so-called "3-D mask effects" which have mostly been neglected before, become important. This paper properly models the 3-D thick mask effects, and then analyses the ...As mask features scale to smaller dimensions, the so-called "3-D mask effects" which have mostly been neglected before, become important. This paper properly models the 3-D thick mask effects, and then analyses the object-based inverse lithography technique using a simulated annealing algorithm to determine the mask shapes that produce the desired on-wafer results. Evaluations against rigorous simulations show that the synthesized masks provide good image fidelity up to 0.94, and this approach gives improved accuracy and faster results than existing methods.展开更多
By using two PM2.5 automatic monitors,the protective effects of five common masks against PM2.5 were synchronously tested under actual ambient air conditions for a whole day. The results showed that not all masks had ...By using two PM2.5 automatic monitors,the protective effects of five common masks against PM2.5 were synchronously tested under actual ambient air conditions for a whole day. The results showed that not all masks had protective effects on PM2.5,and the protective effects of masks N95 and N90,which were designed specially for dust-proof,were superior among the five tested masks.展开更多
Background Hypertension is the main risk factor for cardiovascular diseases, affecting more than half the elderly population. It is essential to know if they have proper control of hypertension. The aim of this study ...Background Hypertension is the main risk factor for cardiovascular diseases, affecting more than half the elderly population. It is essential to know if they have proper control of hypertension. The aim of this study was to identify the associated factors to masked uncon- trolled hypertension and false uncontrolled hypertension in older patients. Methods Two-hundred seventy-three individuals (70.1±6.7 years-old) had blood pressure (BP) measured at the office and by ambulatory BP monitoring (ABPM), with the definition of controlled group (C), individuals with high office BP and adequate ABPM, called white-coat effect group (WCE), uncontrolled (UC), and subjects with ap- propriate office BP and elevated ABPM denominated masked effect group (ME). Age, body mass index, diabetes, pulse pressure (PP) and BP dipping during sleep were evaluated (Kruskal-Wallis test and logistic regression models). Results Age was higher in UC than in C and ME (P 〈 0.01), and 24-h ABPM PP was lower in C (48± 7 mmHg) and WCE (51±6 mmHg) than in UC (67±12 mmHg) and ME (59±8 mmHg) (P 〈 0.01). Sleep systolic BP dipping was lower in ME than in C (P = 0.03). Female gender was associated with a greater chance of being of ME group, which showed a higher PP and lower BP dipping during sleep. Conclusions In older individuals, office BP measure- ments did not allow the detection of associated factors that would permit to differentiate WCE from UC group and C from ME group. ABPM favored the identification of a higher PP and a lower BP dipping during sleep in the masked effect and uncontrolled groups.展开更多
Background: Propofol is the most popular induction agent for laryngeal mask airway (LMA) insertion in current anaesthesia practice however associated hypotension has been reported as its major disadvantage. Etomidate,...Background: Propofol is the most popular induction agent for laryngeal mask airway (LMA) insertion in current anaesthesia practice however associated hypotension has been reported as its major disadvantage. Etomidate, which produces less hypotension, can be considered as an alternative agent for LMA insertion. Objectives: The objective of this study was to compare the hemodynamic effects of etomidate with propofol for induction of general anaesthesia (GA) for LMA. Ease of inserting LMA was also looked at. Material and Methods: It was a prospective randomized double blinded study. All ASA I and II patients of 15 - 60 years of age undergoing general anaesthesia with LMA for elective surgeries were included. Patients were induced with intravenous (I/V) fentanyl and induction agent either etomidate or propofol according to group randomization. LMA was inserted after 30 seconds. Intra-operative heart rate (HR), sys tolic blood pressure (SBP), diastolic blood pressure (DBP), mean arterial pressure (MAP), number of attempts and duration of LMA insertion were monitored. Results: There was no difference in the heart rate between the two groups. A significant drop was found for systolic blood pressure (SBP) in propofol group while diastolic blood pressure (DBP) was decreased in both the groups. In propofol group, successful insertion of LMA was achieved on the first attempt in 93.3% of patient as compared to 36.7% in etomidate group. Conclusion: Use of etomidate for induction of laryngeal mask anesthesia can prevent the hypotension following induction;however it may delay the insertion of laryngeal mask airway.展开更多
A simple generation approach for chaotic sequences with Gauss probability distribution is proposed. Theoretical analysis and simulation based on Logistic chaotic model show that the approach is feasible and effective....A simple generation approach for chaotic sequences with Gauss probability distribution is proposed. Theoretical analysis and simulation based on Logistic chaotic model show that the approach is feasible and effective. The distribution characteristics of the novel chaotic sequence are comparable to that of the standard normal distribution. Its mean and variance can be changed to the desired values. The novel sequences have also good randomness. The applications for radar mask jamming are analyzed.展开更多
基金Supported by the National Key Basic Research and Development(973) Program of China (No. 2006CB302700)the Basic Research Foundation of Tsinghua National Laboratory for Information Science and Technology (TNList)
文摘As mask features scale to smaller dimensions, the so-called "3-D mask effects" which have mostly been neglected before, become important. This paper properly models the 3-D thick mask effects, and then analyses the object-based inverse lithography technique using a simulated annealing algorithm to determine the mask shapes that produce the desired on-wafer results. Evaluations against rigorous simulations show that the synthesized masks provide good image fidelity up to 0.94, and this approach gives improved accuracy and faster results than existing methods.
基金Supported by the Monitoring Scientific Research Foundation of Jiangsu Province,China in 2013(1321)
文摘By using two PM2.5 automatic monitors,the protective effects of five common masks against PM2.5 were synchronously tested under actual ambient air conditions for a whole day. The results showed that not all masks had protective effects on PM2.5,and the protective effects of masks N95 and N90,which were designed specially for dust-proof,were superior among the five tested masks.
文摘Background Hypertension is the main risk factor for cardiovascular diseases, affecting more than half the elderly population. It is essential to know if they have proper control of hypertension. The aim of this study was to identify the associated factors to masked uncon- trolled hypertension and false uncontrolled hypertension in older patients. Methods Two-hundred seventy-three individuals (70.1±6.7 years-old) had blood pressure (BP) measured at the office and by ambulatory BP monitoring (ABPM), with the definition of controlled group (C), individuals with high office BP and adequate ABPM, called white-coat effect group (WCE), uncontrolled (UC), and subjects with ap- propriate office BP and elevated ABPM denominated masked effect group (ME). Age, body mass index, diabetes, pulse pressure (PP) and BP dipping during sleep were evaluated (Kruskal-Wallis test and logistic regression models). Results Age was higher in UC than in C and ME (P 〈 0.01), and 24-h ABPM PP was lower in C (48± 7 mmHg) and WCE (51±6 mmHg) than in UC (67±12 mmHg) and ME (59±8 mmHg) (P 〈 0.01). Sleep systolic BP dipping was lower in ME than in C (P = 0.03). Female gender was associated with a greater chance of being of ME group, which showed a higher PP and lower BP dipping during sleep. Conclusions In older individuals, office BP measure- ments did not allow the detection of associated factors that would permit to differentiate WCE from UC group and C from ME group. ABPM favored the identification of a higher PP and a lower BP dipping during sleep in the masked effect and uncontrolled groups.
文摘Background: Propofol is the most popular induction agent for laryngeal mask airway (LMA) insertion in current anaesthesia practice however associated hypotension has been reported as its major disadvantage. Etomidate, which produces less hypotension, can be considered as an alternative agent for LMA insertion. Objectives: The objective of this study was to compare the hemodynamic effects of etomidate with propofol for induction of general anaesthesia (GA) for LMA. Ease of inserting LMA was also looked at. Material and Methods: It was a prospective randomized double blinded study. All ASA I and II patients of 15 - 60 years of age undergoing general anaesthesia with LMA for elective surgeries were included. Patients were induced with intravenous (I/V) fentanyl and induction agent either etomidate or propofol according to group randomization. LMA was inserted after 30 seconds. Intra-operative heart rate (HR), sys tolic blood pressure (SBP), diastolic blood pressure (DBP), mean arterial pressure (MAP), number of attempts and duration of LMA insertion were monitored. Results: There was no difference in the heart rate between the two groups. A significant drop was found for systolic blood pressure (SBP) in propofol group while diastolic blood pressure (DBP) was decreased in both the groups. In propofol group, successful insertion of LMA was achieved on the first attempt in 93.3% of patient as compared to 36.7% in etomidate group. Conclusion: Use of etomidate for induction of laryngeal mask anesthesia can prevent the hypotension following induction;however it may delay the insertion of laryngeal mask airway.
基金This work was supported by the NEW Laboratory Funding under Grant No.w090403.
文摘A simple generation approach for chaotic sequences with Gauss probability distribution is proposed. Theoretical analysis and simulation based on Logistic chaotic model show that the approach is feasible and effective. The distribution characteristics of the novel chaotic sequence are comparable to that of the standard normal distribution. Its mean and variance can be changed to the desired values. The novel sequences have also good randomness. The applications for radar mask jamming are analyzed.