期刊文献+
共找到20,980篇文章
< 1 2 250 >
每页显示 20 50 100
Performance Assessment of Semiconductor Detector Used in Diagnostics and Interventional Radiology at the Nigerian Secondary Standard Dosimetry Laboratory
1
作者 Samuel Mofolorunsho Oyeyemi Olumide Olaife Akerele +6 位作者 David Olakanmi Olaniyi Francis Adole Agada Sherif Olaniyi Kelani Akinkunmi Emmanuel Ladapo Ahmed Mohammed Shiyanbade Bamidele Musbau Adeniran Latifat Ronke Owoade 《World Journal of Nuclear Science and Technology》 2025年第1期17-29,共13页
Radiation doses to patients in diagnostics and interventional radiology need to be optimized to comply with the principles of radiation protection in medical practice. This involves using specific detectors with respe... Radiation doses to patients in diagnostics and interventional radiology need to be optimized to comply with the principles of radiation protection in medical practice. This involves using specific detectors with respective diagnostic beams to carry out quality control/quality assurance tests needed to optimize patient doses in the hospital. Semiconductor detectors are used in dosimetry to verify the equipment performance and dose to patients. This work aims to assess the performance, energy dependence, and response of five commercially available semiconductor detectors in RQR, RQR-M, RQA, and RQT at Secondary Standard Dosimetry for clinical applications. The diagnostic beams were generated using Exradin A4 reference ion chamber and PTW electrometer. The ambient temperature and pressure were noted for KTP correction. The detectors designed for RQR showed good performance in RQT beams and vice versa. The detectors designed for RQR-M displayed high energy dependency in other diagnostic beams. The type of diagnostic beam quality determines the response of semiconductor detectors. Therefore, a detector should be calibrated according to the beam qualities to be measured. 展开更多
关键词 Semiconductor detectors Optimization of Protection CALIBRATION Patient Dose Diagnostic Radiology
在线阅读 下载PDF
Evaluation of the satellite's wake effect on the electric field detector onboard the CSES-01 satellite
2
作者 JianPing Huang ZongYu Li +4 位作者 Zhong Li XingHong Zhu JunGang Lei YuanQing Miao WenJing Li 《Earth and Planetary Physics》 2025年第2期400-409,共10页
This study aimed to evaluate the wake effect on the electric field detector(EFD) onboard the China Seismo-Electromagnetic Satellite(CSES-01). Through a series of experiments and analyses, we confirmed that the disturb... This study aimed to evaluate the wake effect on the electric field detector(EFD) onboard the China Seismo-Electromagnetic Satellite(CSES-01). Through a series of experiments and analyses, we confirmed that the disturbance phenomenon from probe B of the EFD is not caused by the boom layout. To validate and determine whether it is influenced by the wake effect, we conducted two experiments. In the first experiment, the entire satellite platform underwent a 90° counterclockwise yaw maneuver to allow probe B to avoid the plasma wake region. We then verified whether the disturbance was improved. In the second experiment, the satellite platform performed a 180° counterclockwise yaw maneuver, positioning probe B on the ram side of the satellite and completely avoiding all satellite wakes. The plasma wake effect of the satellite did not significantly influence the spherical probes of the EFD because the measurement accuracy stayed relatively stable under the two experiments, despite the observed abnormalities in the operating state of spherical probe B. This consistency in performance is important for electric field detection missions because the spatial electric field vector data obtained from these probes continue to effectively reflect information on spatial electromagnetic disturbances. These two experimental results showed that probe B consistently exhibited data jump phenomena under various maneuver states, whereas probes A, C, and D did not display such phenomena in any maneuver state. 展开更多
关键词 CSES-01 PAYLOAD electric field detector satellite attitude data quality
在线阅读 下载PDF
Implementation of a double trigger condition system based on charge comparison and TOF measurement for the NEDA detector array
3
作者 J.M.Deltoro A.Goasduff +19 位作者 F.J.Egea V.González A.Gadea R.M.Pérez-Vidal I.Lazarus M.Kogimtzis L.McNicholl M.Palacz G.Jaworski J.J.Valiente-Dobón J.Nyberg S.Casans A.E.Navarro-Antón E.Sanchis A.Boujrad E.Clément T.Hüyük R.Illicachi O.Stezowski V.Modamio 《Nuclear Science and Techniques》 2025年第2期40-48,共9页
The NEutron Detector Array(NEDA)is designed to be coupled to gamma-ray spectrometers to enhance the sensitivity of the setup by enabling reaction channel selection through counting of the evaporated neutrons.This arti... The NEutron Detector Array(NEDA)is designed to be coupled to gamma-ray spectrometers to enhance the sensitivity of the setup by enabling reaction channel selection through counting of the evaporated neutrons.This article presents the implementation of a double trigger condition system for NEDA,which improves the acquisition of neutrons and reduces the number of gamma rays acquired.Two independent triggers are generated in the double trigger condition system:one based on charge comparison(CC)and the other on time-of-flight(TOF).These triggers can be combined using OR and AND logic,offering four distinct trigger modes.The developed firmware is added to the previous one in the Virtex 6 field programmable gate array(FPGA)present in the system,which also includes signal processing,baseline correction,and various trigger logic blocks.The performance of the trigger system is evaluated using data from the E703 experiment performed at GANIL.The four trigger modes are applied to the same data,and a subsequent offline analysis is performed.It is shown that most of the detected neutrons are preserved with the AND mode,and the total number of gamma rays is significantly reduced.Compared with the CC trigger mode,the OR trigger mode allows increasing the selection of neutrons.In addition,it is demonstrated that if the OR mode is selected,the online CC trigger threshold can be raised without losing neutrons. 展开更多
关键词 Neutron detector Neutron-gamma discrimination Pulse shape analysis TIME-OF-FLIGHT Charge comparison
在线阅读 下载PDF
CMOS direct conversion X-ray detector coupled with fluorinated liquid
4
作者 Shi-Hua Liu Chao-Song Gao +5 位作者 Xin Zhang Xiang-Ming Sun Meng Wu Zhi-Hui Han Tong Wan Yong-Shuai Ge 《Nuclear Science and Techniques》 2025年第1期59-68,共10页
X-ray detectors show potential applications in medical imaging,materials science,and nuclear energy.To achieve high detection efficiency and spatial resolution,many conventional semiconductor materials,such as amorpho... X-ray detectors show potential applications in medical imaging,materials science,and nuclear energy.To achieve high detection efficiency and spatial resolution,many conventional semiconductor materials,such as amorphous selenium,cadmium telluride zinc,and perovskites,have been utilized in direct conversion X-ray detectors.However,these semiconductor materials are susceptible to temperature-induced performance degradation,crystallization,delamination,uneven lattice growth,radiation damage,and high dark current.This study explores a new approach by coupling an FC40 electronic fluorinated liquid with a specialized high-resolution and high-readout-speed complementary metal-oxide-semiconductor(CMOS)pixel array,specifically the Topmetal II−chip,to fabricate a direct conversion X-ray detector.The fluorinated liquid FC40(molecular formula:C_(21)F_(48)N_(2))is an electronic medium that is minimally affected by temperature and displays no issues with uniform conductivity.It exhibits a low dark current and minimal radiation damage and enables customizable thickness in X-ray absorption.This addresses the limitations inherent in conventional semiconductor-based detectors.In this study,simple X-ray detector imaging tests were conducted,demonstrating the excellent coupling capability between FC40 electronic fluorinated liquid and CMOS chips by the X-ray detector.A spatial resolution of 4.0 lp/mm was measured using a striped line par card,and a relatively clear image of a cockroach was displayed in the digital radiography imaging results.Preliminary test results indicated the feasibility of fabricating an X-ray detector by combining FC40 electronic fluorinated liquid and CMOS chips.Owing to the absence of issues related to chip-material coupling,a high spatial resolution could be achieved by reducing the chip pixel size.This method presents a new avenue for studies on novel liquid-based direct conversion X-ray detectors. 展开更多
关键词 FC40 electronic fluorinated liquid CMOS pixel chip X-ray detector Spatial resolution
在线阅读 下载PDF
Neutron observations from the energetic particle detector on China's Space Station
5
作者 GuoHong Shen DongHui Hou +5 位作者 Yuan Chang XianGuo Zhang HuanXin Zhang Bin Yuan BinQuan Zhang Ying Sun 《Earth and Planetary Physics》 2025年第2期460-466,共7页
The energetic particle detector on China's space station can determine the energy, flux, and direction of medium-and highenergy protons, electrons, heavy ions, and neutrons within the path of the station's orb... The energetic particle detector on China's space station can determine the energy, flux, and direction of medium-and highenergy protons, electrons, heavy ions, and neutrons within the path of the station's orbit. It also assesses the linear energy transfer(LET)spectra and radiation dose rates generated by these particles. Neutron detection is a significant component of this work, utilizing a new type of Cs_(2)LiYCl_(6): Ce scintillator material along with plastic scintillators as sensors. In-orbit testing has demonstrated the efficient identification of space neutrons and gamma rays(n/γ). This data plays a crucial role in supporting manned space engineering, scientific research, and other related fields. 展开更多
关键词 China's space station energy particle detector neutron detection heavy ion detection radiation effect detection
在线阅读 下载PDF
Readout electronics for the gamma detector of the HIRFL-CSR external target facility
6
作者 Xian-Qin Li Hai-Bo Yang +10 位作者 Xiao-Meng Ma Chao-Jie Zou Tao Liu Xian-Cai Zhou Duo Yan Yang-Zhou Su Shu-Wen Tang Shi-Tao Wang Yu-Hong Yu Zhi-Yu Sun Cheng-Xin Zhao 《Nuclear Science and Techniques》 2025年第2期71-81,共11页
The Cooling Storage Ring of the Heavy Ion Research Facility in Lanzhou(HIRFL-CSR)was constructed to study nuclear physics,atomic physics,interdisciplinary science,and related applications.The External Target Facility(... The Cooling Storage Ring of the Heavy Ion Research Facility in Lanzhou(HIRFL-CSR)was constructed to study nuclear physics,atomic physics,interdisciplinary science,and related applications.The External Target Facility(ETF)is located in the main ring of the HIRFL-CSR.The gamma detector of the ETF is built to measure emitted gamma rays with energies below 5 MeV in the center-of-mass frame and is planned to measure light fragments with energies up to 300 MeV.The readout electronics for the gamma detector were designed and commissioned.The readout electronics consist of thirty-two front-end cards,thirty-two readout control units(RCUs),one common readout unit,one synchronization&clock unit,and one sub-trigger unit.By using the real-time peak-detection algorithm implemented in the RCU,the data volume can be significantly reduced.In addition,trigger logic selection algorithms are implemented to improve the selection of useful events and reduce the data size.The test results show that the integral nonlinearity of the readout electronics is less than 1%,and the energy resolution for measuring the 60 Co source is better than 5.5%.This study discusses the design and performance of the readout electronics. 展开更多
关键词 HIRFL-CSR Gamma detector External target facility Readout electronics Readout control unit Common readout unit Peak-detection algorithm
在线阅读 下载PDF
Reconstruction of pile-up events using a one-dimensional convolutional autoencoder for the NEDA detector array
7
作者 J.M.Deltoro G.Jaworski +15 位作者 A.Goasduff V.González A.Gadea M.Palacz J.J.Valiente-Dobón J.Nyberg S.Casans A.E.Navarro-Antón E.Sanchis G.de Angelis A.Boujrad S.Coudert T.Dupasquier S.Ertürk O.Stezowski R.Wadsworth 《Nuclear Science and Techniques》 2025年第2期62-70,共9页
Pulse pile-up is a problem in nuclear spectroscopy and nuclear reaction studies that occurs when two pulses overlap and distort each other,degrading the quality of energy and timing information.Different methods have ... Pulse pile-up is a problem in nuclear spectroscopy and nuclear reaction studies that occurs when two pulses overlap and distort each other,degrading the quality of energy and timing information.Different methods have been used for pile-up rejection,both digital and analogue,but some pile-up events may contain pulses of interest and need to be reconstructed.The paper proposes a new method for reconstructing pile-up events acquired with a neutron detector array(NEDA)using an one-dimensional convolutional autoencoder(1D-CAE).The datasets for training and testing the 1D-CAE are created from data acquired from the NEDA.The new pile-up signal reconstruction method is evaluated from the point of view of how similar the reconstructed signals are to the original ones.Furthermore,it is analysed considering the result of the neutron-gamma discrimination based on charge comparison,comparing the result obtained from original and reconstructed signals. 展开更多
关键词 1D-CAE Autoencoder CAE Convolutional neural network(CNN) Neutron detector Neutron-gamma discrimination(NGD) Machine learning Pulse shape discrimination Pile-up pulse
在线阅读 下载PDF
Image-Based Brachytherapy in Cervical Cancer: Review and Experiences in Faculty of Medicine, Chiang Mai University 被引量:2
8
作者 Ekkasit Tharavichitkul Somvilai Chakrabandhu +2 位作者 Pitchayaponne Klunklin Wimrak Onchan Imjai Chitapanarux 《Journal of Cancer Therapy》 2013年第5期1-7,共7页
Cervical cancer is the one of the most common cancer in female patients inThailand. Radiotherapy has the role for the treatment of cervical cancer by postoperative, radical and palliative treatments. For radical radio... Cervical cancer is the one of the most common cancer in female patients inThailand. Radiotherapy has the role for the treatment of cervical cancer by postoperative, radical and palliative treatments. For radical radiotherapy, the combination of external beam radiation therapy and brachytherapy will be used to increase the tumor dose to curative goal. With the new development of medical images (Computed tomography (CT), Magnetic Resonance Imaging (MRI) or Ultrasonography (US)), the treatment with brachytherapy will be developed from point-based to volume-based concepts. Many studies reported the benefit of image-based brachytherapy over conventional brachytherapy and clinical benefit of using image-based brachytherapy in the treatment of cervical cancer. 展开更多
关键词 image-based BRACHYTHERAPY Cervical Cancer REVIEW
在线阅读 下载PDF
A review on image-based rendering 被引量:1
9
作者 Yuan CHANG Guo-Ping WANG 《Virtual Reality & Intelligent Hardware》 2019年第1期39-54,共16页
Image-based rendering is important both in the field of computer graphics and computer vision,and it is also widely used in virtual reality technology.For more than two decades,people have done a lot of work on the re... Image-based rendering is important both in the field of computer graphics and computer vision,and it is also widely used in virtual reality technology.For more than two decades,people have done a lot of work on the research of image-based rendering,and these methods can be divided into two categories according to whether the geometric information of the scene is utilized.According to this classification,we introduce some classical methods and representative methods proposed in recent years.We also compare and analyze the basic principles,advantages and disadvantages of different methods.Finally,some suggestions are given for research directions on image-based rendering techniques in the future. 展开更多
关键词 image-based rendering Virtual reality Image interpolation PANORAMA
在线阅读 下载PDF
PTW Detector7293种剂量验证方法在调强放射治疗中的对比研究
10
作者 吴晓辉 姚祖文 +4 位作者 徐珊珊 罗桃红 胡小容 姚阳 王晓华 《医疗卫生装备》 CAS 2024年第5期56-59,共4页
目的 :对比PTW Detector729 3种验证方法在调强放射治疗(intensity modulated radiation therapy,IMRT)剂量验证中的差异。方法:回顾性选取2022年1—12月于某院完成放射治疗的鼻咽癌、肺癌、乳腺癌、宫颈癌和全脑放射治疗患者共50例,使... 目的 :对比PTW Detector729 3种验证方法在调强放射治疗(intensity modulated radiation therapy,IMRT)剂量验证中的差异。方法:回顾性选取2022年1—12月于某院完成放射治疗的鼻咽癌、肺癌、乳腺癌、宫颈癌和全脑放射治疗患者共50例,使用PTW Detector729二维电离室矩阵配合PTW RW3固体水与PTW Ocavius 4D旋转模体对50例患者的IMRT计划分别进行归零机架角2D剂量验证、实际机架角2D剂量验证和实际机架角3D剂量验证。将剂量评估阈值设为10%,统计3种验证方法在3%/1 mm、2%/2 mm、3%/2 mm和3%/3 mm 4种评估标准下的γ通过率。采用SPSS 22.0统计学软件进行数据分析。结果:在10%剂量评估阈值标准下,归零机架角2D剂量验证的γ通过率最高,差异有统计学意义(P<0.05);实际机架角2D剂量验证的γ通过率高于实际机架角3D剂量验证,差异有统计学意义(P<0.05)。3种验证方法的γ通过率在3%/1 mm、2%/2 mm、3%/2 mm和3%/3 mm 4种标准下逐渐升高,且在3%/2 mm标准下均超过90%,结果满足临床放射治疗要求。结论:3种验证方法的验证结果均能达到IMRT剂量验证实践指南要求,根据IMRT开展情况选择合适的验证方法,对确保治疗方案安全、有效实施具有重要意义。 展开更多
关键词 PTW detector729 二维电离室矩阵 剂量验证 γ通过率 调强放射治疗
在线阅读 下载PDF
Three Dimensional Microstructure and Image-Based Simulation of a Fly Ash/Al Syntactic Foam Using X-ray Micro-Computed Tomography
11
作者 张强 WU Gaohui 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2013年第1期99-103,共5页
An aluminum matrix syntactic foam, incorporated with hollow-structured fly ash particles, was fabricated by pressure infiltration technique. X-ray micro-computed tomography was used to characterize its heterogeneous m... An aluminum matrix syntactic foam, incorporated with hollow-structured fly ash particles, was fabricated by pressure infiltration technique. X-ray micro-computed tomography was used to characterize its heterogeneous microstructure three dimensionally (3D). The quantification of some microstructure features, such as content and size distribution of hollow fly ash particles, was acquired in 3D. The tomographic data were exploited as a rapid method to generate a microstructurally accurate and robust 3D meshed model. The thermal transport behavior has been modeled using a commercial finite-element code to conduct steady state analyses. Simulation of the thermal conductivity showed good correlation with experimental result. 展开更多
关键词 fly ash syntactic foam TOMOGRAPHY MICROSTRUCTURE image-based simulation
在线阅读 下载PDF
基于InVEST和Geodetector模型的合肥生境质量时空演变及影响因素分析 被引量:2
12
作者 智菲 周振宏 +2 位作者 赵铭 杨宗霖 高超群 《河北环境工程学院学报》 CAS 2024年第3期49-54,共6页
依据2000年、2010年和2020年3期土地利用数据,运用耦合模型探究合肥2000—2020年间生境质量时空变化特征并对影响因子进行分析。结果表明:2000—2020年合肥生境质量指数平均值分别为0.185、0.181、0.178,呈逐年下降趋势,较低质量区域向... 依据2000年、2010年和2020年3期土地利用数据,运用耦合模型探究合肥2000—2020年间生境质量时空变化特征并对影响因子进行分析。结果表明:2000—2020年合肥生境质量指数平均值分别为0.185、0.181、0.178,呈逐年下降趋势,较低质量区域向低质量区域的转移面积最大。合肥生境质量退化度在2000—2020年逐年下降,呈现出“环状增长”的空间分布特征。高退化度区域主要分布在低值区域外围,呈现非连续性扩张。区域生产总值、坡度以及高程是主要影响因子,双因子增强效应显著,年末总人口和人口密度为主导单因子。 展开更多
关键词 合肥市 InVEST模型 地理探测器 生境质量 驱动因子
在线阅读 下载PDF
Metal-Halide Perovskite Submicrometer-Thick Films for Ultra-Stable Self-Powered Direct X-Ray Detectors 被引量:1
13
作者 Marco Girolami Fabio Matteocci +7 位作者 Sara Pettinato Valerio Serpente Eleonora Bolli Barbara Paci Amanda Generosi Stefano Salvatori Aldo Di Carlo Daniele M.Trucchi 《Nano-Micro Letters》 SCIE EI CAS CSCD 2024年第9期410-431,共22页
Metal-halide perovskites are revolutionizing the world of X-ray detectors,due to the development of sensitive,fast,and cost-effective devices.Self-powered operation,ensuring portability and low power consumption,has a... Metal-halide perovskites are revolutionizing the world of X-ray detectors,due to the development of sensitive,fast,and cost-effective devices.Self-powered operation,ensuring portability and low power consumption,has also been recently demonstrated in both bulk materials and thin films.However,the signal stability and repeatability under continuous X-ray exposure has only been tested up to a few hours,often reporting degradation of the detection performance.Here it is shown that self-powered direct X-ray detectors,fabricated starting from a FAPbBr_(3)submicrometer-thick film deposition onto a mesoporous TiO_(2)scaffold,can withstand a 26-day uninterrupted X-ray exposure with negligible signal loss,demonstrating ultra-high operational stability and excellent repeatability.No structural modification is observed after irradiation with a total ionizing dose of almost 200 Gy,revealing an unexpectedly high radiation hardness for a metal-halide perovskite thin film.In addition,trap-assisted photoconductive gain enabled the device to achieve a record bulk sensitivity of 7.28 C Gy^(−1)cm^(−3)at 0 V,an unprecedented value in the field of thin-film-based photoconductors and photodiodes for“hard”X-rays.Finally,prototypal validation under the X-ray beam produced by a medical linear accelerator for cancer treatment is also introduced. 展开更多
关键词 Metal-halide perovskite thin films Direct X-ray detectors Self-powered devices Operational stability Medical linear accelerator
在线阅读 下载PDF
High-speed performance self-powered short wave ultraviolet radiation detectors based onκ(ε)-Ga_(2)O_(3) 被引量:1
14
作者 Aleksei Almaev Alexander Tsymbalov +5 位作者 Bogdan Kushnarev Vladimir Nikolaev Alexei Pechnikov Mikhail Scheglov Andrei Chikiryaka Petr Korusenko 《Journal of Semiconductors》 EI CAS CSCD 2024年第4期56-62,共7页
High-speed solar-blind short wavelength ultraviolet radiation detectors based onκ(ε)-Ga_(2)O_(3)layers with Pt contacts were demonstrated and their properties were studied in detail.Theκ(ε)-Ga_(2)O_(3)layers were ... High-speed solar-blind short wavelength ultraviolet radiation detectors based onκ(ε)-Ga_(2)O_(3)layers with Pt contacts were demonstrated and their properties were studied in detail.Theκ(ε)-Ga_(2)O_(3)layers were deposited by the halide vapor phase epitaxy on patterned GaN templates with sapphire substrates.The spectral dependencies of the photoelectric properties of struc-tures were analyzed in the wavelength interval 200-370 nm.The maximum photo to dark current ratio,responsivity,detectiv-ity and external quantum efficiency of structures were determined as:180.86 arb.un.,3.57 A/W,1.78×10^(12) Hz^(0.5)∙cm·W^(-1) and 2193.6%,respectively,at a wavelength of 200 nm and an applied voltage of 1 V.The enhancement of the photoresponse was caused by the decrease in the Schottky barrier at the Pt/κ(ε)-Ga_(2)O_(3)interface under ultraviolet exposure.The detectors demon-strated could functionalize in self-powered mode due to built-in electric field at the Pt/κ(ε)-Ga_(2)O_(3)interface.The responsivity and external quantum efficiency of the structures at a wavelength of 254 nm and zero applied voltage were 0.9 mA/W and 0.46%,respectively.The rise and decay times in self-powered mode did not exceed 100 ms. 展开更多
关键词 κ(ε)-gallium oxide solar-blind shortwave ultraviolet radiation detectors self-powered operation mode
在线阅读 下载PDF
Low-noise and low-power pixel sensor chip for gas pixel detectors
15
作者 Zhuo Zhou Shi-Qiang Zhou +8 位作者 Dong Wang Xiang-Ming Sun Chao-Song Gao Peng-Zhen Zhu Wei-Ping Ren Jun Liu Mu-Xian Li Chen Lian Chun-Lai Dong 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第3期142-152,共11页
Topmetal-M2 is a large-area pixel sensor chip fabricated using the GSMC 130 nm CMOS process in 2021.The pixel array of Topmetal-M2 consists of pixels of 400 rows×512 columns with a pixel pitch of 45μm×45μm... Topmetal-M2 is a large-area pixel sensor chip fabricated using the GSMC 130 nm CMOS process in 2021.The pixel array of Topmetal-M2 consists of pixels of 400 rows×512 columns with a pixel pitch of 45μm×45μm.The array is divided into 16 subarrays,with pixels of 400 rows×32 columns per subarray.Each pixel incorporates two charge sensors:a diode sensor and a Topmetal sensor.The in-pixel circuit primarily consists of a charge-sensitive amplifier for energy measurements,a discriminator with a peak-holding circuit,and a time-to-amplitude converter for time-of-arrival measurements.The pixel of Topmetal-M2 has a charge input range of~0-3 k e-,a voltage output range of~0-180 mV,and a charge-voltage conversion gain of~59.56μV∕e-.The average equivalent noise charge of Topmetal-M2,which includes the readout electronic system noise,is~43.45 e-.In the scanning mode,the time resolution of Topmetal-M2 is 1 LSB=1.25μs,and the precision is^()7.41μs.At an operating voltage of 1.5 V,Topmetal-M2 has a power consumption of~49 mW∕cm~2.In this article,we provide a comprehensive overview of the chip architecture,pixel working principles,and functional behavior of Topmetal-M2.Furthermore,we present the results of preliminary tests conducted on Topmetal-M2,namely,alpha-particle and soft X-ray tests. 展开更多
关键词 Charge collection Gas detectors Semiconductor detectors X-ray detectors
在线阅读 下载PDF
CVTD: A Robust Car-Mounted Video Text Detector
16
作者 Di Zhou Jianxun Zhang +2 位作者 Chao Li Yifan Guo Bowen Li 《Computers, Materials & Continua》 SCIE EI 2024年第2期1821-1842,共22页
Text perception is crucial for understanding the semantics of outdoor scenes,making it a key requirement for building intelligent systems for driver assistance or autonomous driving.Text information in car-mounted vid... Text perception is crucial for understanding the semantics of outdoor scenes,making it a key requirement for building intelligent systems for driver assistance or autonomous driving.Text information in car-mounted videos can assist drivers in making decisions.However,Car-mounted video text images pose challenges such as complex backgrounds,small fonts,and the need for real-time detection.We proposed a robust Car-mounted Video Text Detector(CVTD).It is a lightweight text detection model based on ResNet18 for feature extraction,capable of detecting text in arbitrary shapes.Our model efficiently extracted global text positions through the Coordinate Attention Threshold Activation(CATA)and enhanced the representation capability through stacking two Feature Pyramid Enhancement Fusion Modules(FPEFM),strengthening feature representation,and integrating text local features and global position information,reinforcing the representation capability of the CVTD model.The enhanced feature maps,when acted upon by Text Activation Maps(TAM),effectively distinguished text foreground from non-text regions.Additionally,we collected and annotated a dataset containing 2200 images of Car-mounted Video Text(CVT)under various road conditions for training and evaluating our model’s performance.We further tested our model on four other challenging public natural scene text detection benchmark datasets,demonstrating its strong generalization ability and real-time detection speed.This model holds potential for practical applications in real-world scenarios. 展开更多
关键词 Deep learning text detection Car-mounted video text detector intelligent driving assistance arbitrary shape text detector
在线阅读 下载PDF
Flexibility potential of Cs_(2)BX_(6)(B=Hf,Sn,Pt,Zr,Ti;X=I,Br,Cl)with application in photovoltaic devices and radiation detectors
17
作者 Songya Wang Changcheng Chen +11 位作者 Shaohang Shi Ziyi Zhang Yan Cai Shuli Gao Wen Chen Shuangna Guo Elyas Abduryim Chao Dong Xiaoning Guan Ying Liu Gang Liu Pengfei Lu 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2024年第8期271-287,I0006,共18页
As interest in double perovskites is growing,especially in applications like photovoltaic devices,understanding their mechanical properties is vital for device durability.Despite extensive exploration of structure and... As interest in double perovskites is growing,especially in applications like photovoltaic devices,understanding their mechanical properties is vital for device durability.Despite extensive exploration of structure and optical properties,research on mechanical aspects is limited.This article builds a vacancyordered double perovskite model,employing first-principles calculations to analyze mechanical,bonding,electronic,and optical properties.Results show Cs_(2)Hfl_(6),Cs_(2)SnBr_(6),Cs_(2)SnI_(6),and Cs_(2)PtBr_(6)have Young's moduli below 13 GPa,indicating flexibility.Geometric parameters explain flexibility variations with the changes of B and X site composition.Bonding characteristic exploration reveals the influence of B and X site electronegativity on mechanical strength.Cs_(2)SnBr_(6)and Cs_(2)PtBr_(6)are suitable for solar cells,while Cs_(2)HfI_(6)and Cs_(2)TiCl_(6)show potential for semi-transparent solar cells.Optical property calculations highlight the high light absorption coefficients of up to 3.5×10^(5) cm^(-1)for Cs_(2)HfI_(6)and Cs_(2)TiCl_(6).Solar cell simulation shows Cs_(2)PtBr_(6)achieves 22.4%of conversion effciency.Cs_(2)ZrCl_(6)holds promise for ionizing radiation detection with its 3.68 eV bandgap and high absorption coefficient.Vacancy-ordered double perovskites offer superior flexibility,providing valuable insights for designing stable and flexible devices.This understanding enhances the development of functional devices based on these perovskites,especially for applications requiring high stability and flexibility. 展开更多
关键词 Double perovskite Mechanical properties Flexible PHOTOVOLTAIC Radiation detectors
在线阅读 下载PDF
Design and performance evaluation of a large field-of-view dual-particle time-encoded imager based on a depth-of-interaction detector
18
作者 Dong Zhao Xu-Wen Liang +6 位作者 Ping-Kun Cai Wei Cheng Wen-Bao Jia Da-Qian Hei Qing Shan Yong-Sheng Ling Chao Shi 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第4期1-14,共14页
Time-encoded imaging is useful for identifying potential special nuclear materials and other radioactive sources at a distance.In this study,a large field-of-view time-encoded imager was developed for gamma-ray and ne... Time-encoded imaging is useful for identifying potential special nuclear materials and other radioactive sources at a distance.In this study,a large field-of-view time-encoded imager was developed for gamma-ray and neutron source hotspot imaging based on a depth-of-interaction(DOI)detector.The imager primarily consists of a DOI detector system and a rotary dual-layer cylindrical coded mask.An EJ276 plastic scintillator coupled with two SiPMs was designed as the DOI detector to increase the field of view and improve the imager performance.The difference in signal time at both ends and the log of the signal amplitude ratio were used to calculate the interaction position resolution.The position resolution of the DOI detector was calibrated using a collimated Cs-137 source,and the full width at half maximum of the reconstruction position of the Gaussian fitting curve was approximately 4.4 cm.The DOI detector can be arbitrarily divided into several units to independently reconstruct the source distribution images.The unit length was optimized via Am-Be source-location experiments.A multidetector filtering method is proposed for image denoising.This method can effectively reduce image noise caused by poor DOI detector position resolution.The vertical field of view of the imager was(-55°,55°)when the detector was placed in the center of the coded mask.A DT neutron source at 20 m standoff could be located within 2400 s with an angular resolution of 3.5°. 展开更多
关键词 Time-encoded imager Depth-of-interaction detector Dual-particle imaging Hotspot imaging
在线阅读 下载PDF
Method for detector description conversion from DD4hep to Filmbox
19
作者 Zhao-Yang Yuan Tian-Zi Song +3 位作者 Yu-Jie Zeng Kai-Xuan Huang Yu-Mei Zhang Zheng-Yun You 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第9期115-126,共12页
DD4hep serves as a generic detector description toolkit recommended for offline software development in next-generation high-energy physics(HEP)experiments.Conversely,Filmbox(FBX)stands out as a widely used 3D modelin... DD4hep serves as a generic detector description toolkit recommended for offline software development in next-generation high-energy physics(HEP)experiments.Conversely,Filmbox(FBX)stands out as a widely used 3D modeling file format within the 3D software industry.In this paper,we introduce a novel method that can automatically convert complex HEP detector geometries from DD4hep description into 3D models in the FBX format.The feasibility of this method was dem-onstrated by its application to the DD4hep description of the Compact Linear Collider detector and several sub-detectors of the super Tau-Charm facility and circular electron-positron collider experiments.The automatic DD4hep–FBX detector conversion interface provides convenience for further development of applications,such as detector design,simulation,visualization,data monitoring,and outreach,in HEP experiments. 展开更多
关键词 detector description DD4hep FBX GEOMETRY Offline software
在线阅读 下载PDF
Self-powered UVC detectors based on α-Ga_(2)O_(3) with enchanted speed performance
20
作者 Aleksei Almaev Alexander Tsymbalov +4 位作者 Bogdan Kushnarev Vladimir Nikolaev Alexei Pechnikov Mikhail Scheglov Andrei Chikiryaka 《Journal of Semiconductors》 EI CAS CSCD 2024年第8期74-80,共7页
Detectors were developed for detecting irradiation in the short-wavelength ultraviolet(UVC)interval using high-quality single-crystallineα-Ga_(2)O_(3) films with Pt interdigital contacts.The films ofα-Ga_(2)O_(3) we... Detectors were developed for detecting irradiation in the short-wavelength ultraviolet(UVC)interval using high-quality single-crystallineα-Ga_(2)O_(3) films with Pt interdigital contacts.The films ofα-Ga_(2)O_(3) were grown on planar sapphire substrates with c-plane orientation using halide vapor phase epitaxy.The spectral dependencies of the photo to dark current ratio,responsivity,external quantum efficiency and detectivity of the structures were investigated in the wavelength interval of 200−370 nm.The maximum of photo to dark current ratio,responsivity,external quantum efficiency,and detectivity of the structures were 1.16×10^(4) arb.un.,30.6 A/W,1.65×10^(4)%,and 6.95×10^(15) Hz^(0.5)·cm/W at a wavelength of 230 nm and an applied voltage of 1 V.The high values of photoelectric properties were due to the internal enhancement of the photoresponse associated with strong hole trapping.Theα-Ga_(2)O_(3) film-based UVC detectors can function in self-powered operation mode due to the built-in electric field at the Pt/α-Ga_(2)O_(3) interfaces.At a wavelength of 254 nm and zero applied voltage,the structures exhibit a responsivity of 0.13 mA/W and an external quantum efficiency of 6.2×10^(−2)%.The UVC detectors based on theα-Ga_(2)O_(3) films demonstrate high-speed performance with a rise time of 18 ms in self-powered mode. 展开更多
关键词 HVPE gallium oxide solar-blind ultraviolet detector self-powered mode
在线阅读 下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部