期刊文献+
共找到246篇文章
< 1 2 13 >
每页显示 20 50 100
Simulation study on reconstruction model of three-dimensional temperature distribution within visible range in furnace 被引量:1
1
作者 刘冬 王飞 +3 位作者 黄群星 严建华 池涌 岑可法 《Chinese Physics B》 SCIE EI CAS CSCD 2008年第4期1312-1317,共6页
This paper presents a reconstruction model of three-dimensional temperature distribution in furnace based on radiative energy images captured by charge-coupled device (CCD) cameras within the visible wavelength rang... This paper presents a reconstruction model of three-dimensional temperature distribution in furnace based on radiative energy images captured by charge-coupled device (CCD) cameras within the visible wavelength range. Numerical simulation case was used in this study and a zigzag eccentric temperature distribution was assumed to verify the model. Least square QR-factorization (LSQR) method was introduced to deal with reconstruction equation. It is found that the reconstructed temperature distributions in low-temperature areas had some fluctuations and high-temperature areas were reconstructed well. The whole reconstruction relative error was mainly due to errors in low-temperature areas and the relative error for highest-temperature reconstruction was quite small. 展开更多
关键词 three-dimensional temperature distribution radiative energy images visible range charge-coupled device
在线阅读 下载PDF
Development of D_α band symmetrical visible optical diagnostic for boundary reconstruction on EAST tokamak
2
作者 陈明 沈飊 +4 位作者 Shinichiro KADO 郭笔豪 陈大龙 蔡福瑞 肖炳甲 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第2期44-53,共10页
To investigate the potential of utilizing visible spectral imaging for controlling the plasma boundary shape during stable operation of plasma in future tokamak, a D_α band symmetric visible light diagnostic system w... To investigate the potential of utilizing visible spectral imaging for controlling the plasma boundary shape during stable operation of plasma in future tokamak, a D_α band symmetric visible light diagnostic system was designed and implemented on the Experimental Advanced Superconducting Tokamak(EAST). This system leverages two symmetric optics for joint plasma imaging. The optical system exhibits a spatial resolution less than 2 mm at the poloidal cross-section, distortion within the field of view below 10%, and relative illumination of 91%.The high-quality images obtained enable clear observation of both the plasma boundary position and the characteristics of components within the vacuum vessel. Following system calibration and coordinate transformation, the image coordinate boundary features are mapped to the tokamak coordinate system. Utilizing this system, the plasma boundary was reconstructed, and the resulting representation showed alignment with the EFIT(Equilibrium Fitting) results. This underscores the system's superior performance in boundary reconstruction applications and provides a diagnostic foundation for boundary shape control based on visible spectral imaging. 展开更多
关键词 visible optical diagnostic plasma boundary reconstruction EAST
在线阅读 下载PDF
3D Vector Reconstruction of the Typical Cervical Vertebra from Anatomical Sections of Korean Visible Human at the Laboratory of Clinical and Digital Anatomy of Paris Descartes University
3
作者 Abdoulaye Kanté Jean Franç +7 位作者 ois Uhl Mariam Daou Vincent Delmas J. S. Park B. S. Chung Babou Ba Nouhoum Ongoï ba 《Forensic Medicine and Anatomy Research》 2020年第3期55-63,共9页
<strong>Aim:</strong> To carry out a 3D vector reconstruction of the typical cervical vertebra from anatomical sections of the “Korean Visible Human” for educational purposes. <strong>Material and ... <strong>Aim:</strong> To carry out a 3D vector reconstruction of the typical cervical vertebra from anatomical sections of the “Korean Visible Human” for educational purposes. <strong>Material and Methods:</strong> The anatomical subject was a 33-year-old Korean man who died of leukemia. He was 164 cm tall and weighed 55 kg. This man donated his body to science. Her body was frozen and cut into several anatomical sections after an MRI and CT scan. These anatomical sections were made using a special saw called a 0.2 mm thick cryomacrotome. Thus 8100 cuts were obtained. Only the sections numbered 940 to 1200 were used for our study. A segmentation by manual contouring of the different parts of the typical cervical vertebra was made using the software Winsurf version 3.5 on a laptop PC running Windows 7 equipped with a Ram of 8 gigas. <strong>Results:</strong> Our 3D vector model of the typical cervical vertebra is easily manipulated using the Acrobat 3DPDF interface. Each part of the vertebra accessible in a menu can be displayed, hidden or made transparent, and 3D labels are available as well as educational menus for learning anatomy. <strong>Conclusion: </strong>This original work constitutes a remarkable educational tool for the anatomical study of the typical cervical vertebra and can also be used as a 3D atlas for simulation purposes for training in therapeutic gestures. 展开更多
关键词 three-dimensional Anatomy Korean Human visible Modeling of the Typical Cervical Vertebra Virtual Reality 3D reconstruction Virtual Dissection Surgical Simulation Surgical Training
在线阅读 下载PDF
Construction of three-dimensional atlas of the lenticular nuclei and its subnucleus based on the cryosection images from Chinese visible human:a preliminary study
4
作者 陈晓光 《外科研究与新技术》 2011年第3期227-227,共1页
Objective To establish a 3D atlas of the lenticular nuclei and its subnucleus with the cryosection images of the male from "Atlas of Chinese Visible Human". Methods The lenticular nuclei and its subnucleus w... Objective To establish a 3D atlas of the lenticular nuclei and its subnucleus with the cryosection images of the male from "Atlas of Chinese Visible Human". Methods The lenticular nuclei and its subnucleus were segmented from the cryosection images and reconstructed with the software 展开更多
关键词 Construction of three-dimensional atlas of the lenticular nuclei and its subnucleus based on the cryosection images from Chinese visible human
在线阅读 下载PDF
Three-dimensional reconstruction under computed tomography and myopectineal orifice measurement under laparoscopy for quality control of inguinal hernia treatment
5
作者 Lei Zhang Jing Chen +7 位作者 Yu-Ying Zhang Lei Liu Han-Dan Wang Ya-Fei Zhang Jun Sheng Qiu-Shi Hu Ming-Liang Liu Yi-Lin Yuan 《World Journal of Gastrointestinal Endoscopy》 2025年第3期50-59,共10页
BACKGROUND Inguinal hernias are common after surgery.Tension-free repair is widely accepted as the main method for managing inguinal hernias.Adequate exposure,coverage,and repair of the myopectineal orifice(MPO)are ne... BACKGROUND Inguinal hernias are common after surgery.Tension-free repair is widely accepted as the main method for managing inguinal hernias.Adequate exposure,coverage,and repair of the myopectineal orifice(MPO)are necessary.However,due to differences in race and sex,people’s body shapes vary.According to European guidelines,the patch should measure 10 cm×15 cm.If any part of the MPO is dissected,injury to the nerves,vascular network,or organs may occur during surgery,thereby leading to inguinal discomfort,pain,and seroma formation after surgery.Therefore,accurate localization and measurement of the boundary of the MPO are crucial for selecting the optimal patch for inguinal hernia repair.AIM To compare the size of the MPO measured on three-dimensional multislice spiral computed tomography(CT)with that measured via laparoscopy and explore the relevant factors influencing the size of the MPO.METHODS Clinical data from 74 patients who underwent laparoscopic tension-free inguinal hernia repair at the General Surgery Department of the First Affiliated Hospital of Anhui University of Science and Technology between September 2022 and July 2024 were collected and analyzed retrospectively.Transabdominal preperitoneal was performed.Sixty-four males and 10 females,with an average age of 58.30±12.32 years,were included.The clinical data of the patients were collected.The boundary of the MPO was measured on three-dimensional CT images before surgery and then again during transabdominal preperitoneal.All the preoperative and intraoperative data were analyzed via paired t-tests.A t-test was used for comparisons of age,body mass index,and sex between the groups.In the comparative analysis,a P value less than 0.05 indicated a significant difference.RESULTS The boundaries of the MPO on 3-dimensional CT images measured 7.05±0.47 cm and 6.27±0.61 cm,and the area of the MPO was 19.54±3.33 cm^(2).The boundaries of the MPO during surgery were 7.18±0.51 cm and 6.17±0.40 cm.The errors were not statistically significant.However,the intraoperative BD(the width of the MPO,P=0.024,P<0.05)and preoperative AC(the length of the MPO,P=0.045,P<0.05)significantly differed according to sex.The AC and BD measurements before and during surgery were not significantly different according to age,body mass index,hernia side or hernia type(P>0.05).CONCLUSION The application of this technology can aid in determining the most appropriate dissection range and patch size. 展开更多
关键词 HERNIA INGUINAL Myopectineal orifice three-dimensional reconstruction Computed tomography Inguinal hernia
在线阅读 下载PDF
Three-dimensional reconstruction of digitized human liver: based on Chinese Visible Human 被引量:18
6
作者 CHEN Gang LI Xue-cheng +7 位作者 WU Guo-qing ZHANG Shao-xiang XIONG Xiao-feng TAN Li-wen YANG Ri-gao LI Kai YANG Shi-zhong DONG Jia-hong 《Chinese Medical Journal》 SCIE CAS CSCD 2010年第2期146-150,共5页
Background Comparing with two dimensional (2D) imaging, both in diagnosis and treatment, three dimensional (3D) imaging has many advantages in clinical medicine. 3D reconstruction makes the target easier to identi... Background Comparing with two dimensional (2D) imaging, both in diagnosis and treatment, three dimensional (3D) imaging has many advantages in clinical medicine. 3D reconstruction makes the target easier to identify and reveals the volume and shape of the organ much better than 2D imaging. A 3D digitized visible model of the liver was built to provide anatomical structure for planing of hepatic operation and for realizing accurate simulation of the liver on the computer. Methods Transverse sections of abdomen were chosen from the Chinese Visible Human dataset. And Amira software was selected to segment and reconstruct the structures of the liver. The liver was reconstructed in three-dimensions with both surface and volume rendering reconstruction. Results Accurately segmented images of the main structures of the liver were completed. The reconstructed structures can be displayed singly, in small groups or as a whole and can be continuously rotated in 3D space at different velocities. Conclusions The reconstructed liver is realistic, which demonstrates the natural shape and exact position of liver structures, tt provides an accurate model for the automated segmentation algorithmic study and a digitized anatomical mode of viewing the liver. 展开更多
关键词 visible human LIVER three-dimensional reconstruction visualization
原文传递
Computed tomography three-dimensional reconstruction in the diagnosis of bleeding small intestinal polyps:A case report
7
作者 Shu-Hui Zhang Ming-Wei Fan +2 位作者 Yan Chen Ying-Bin Hu Cheng-Xia Liu 《World Journal of Clinical Cases》 SCIE 2024年第16期2831-2836,共6页
BACKGROUND Computed tomography(CT)small bowel three-dimensional(3D)reconstruction is a powerful tool for the diagnosis of small bowel disease and can clearly show the intestinal lumen and wall as well as the outside s... BACKGROUND Computed tomography(CT)small bowel three-dimensional(3D)reconstruction is a powerful tool for the diagnosis of small bowel disease and can clearly show the intestinal lumen and wall as well as the outside structure of the wall.The horizontal axis position can show the best adjacent intestinal tube and the lesion between the intestinal tubes,while the coronal position can show the overall view of the small bowel.The ileal end of the localization of the display of excellent,and easy to quantitative measurement of the affected intestinal segments,the sagittal position for the rectum and the pre-sacral lesions show the best,for the discovery of fistulae is also helpful.Sagittal view can show rectal and presacral lesions and is useful for fistula detection.It is suitable for the assessment of inflammatory bowel disease,such as assessment of disease severity and diagnosis and differential diagnosis of the small bowel and mesenteric space-occupying lesions as well as the judgment of small bowel obstruction points.CASE SUMMARY Bleeding caused by small intestinal polyps is often difficult to diagnose in clinical practice.This study reports a 29-year-old male patient who was admitted to the hospital with black stool and abdominal pain for 3 months.Using the combination of CT-3D reconstruction and capsule endoscopy,the condition was diagnosed correctly,and the polyps were removed using single-balloon enteroscopyendoscopic retrograde cholangiopancreatography without postoperative complications.CONCLUSION The role of CT-3D in gastrointestinal diseases was confirmed.CT-3D can assist in the diagnosis and treatment of gastrointestinal diseases in combination with capsule endoscopy and small intestinal microscopy. 展开更多
关键词 Computed tomography three-dimensional reconstruction Capsule endoscopy Single-balloon enteroscopy Gastrointestinal bleeding Case report
在线阅读 下载PDF
Evaluating the use of three-dimensional reconstruction visualization technology for precise laparoscopic resection in gastroesophageal junction cancer
8
作者 Dan Guo Xiao-Yan Zhu +2 位作者 Shuai Han Yu-Shu Liu Da-Peng Cui 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第5期1311-1319,共9页
BACKGROUND Laparoscopic gastrectomy for esophagogastric junction(EGJ)carcinoma enables the removal of the carcinoma at the junction between the stomach and esophagus while preserving the gastric function,thereby provi... BACKGROUND Laparoscopic gastrectomy for esophagogastric junction(EGJ)carcinoma enables the removal of the carcinoma at the junction between the stomach and esophagus while preserving the gastric function,thereby providing patients with better treatment outcomes and quality of life.Nonetheless,this surgical technique also presents some challenges and limitations.Therefore,three-dimensional reconstruction visualization technology(3D RVT)has been introduced into the procedure,providing doctors with more comprehensive and intuitive anatomical information that helps with surgical planning,navigation,and outcome evaluation.AIM To discuss the application and advantages of 3D RVT in precise laparoscopic resection of EGJ carcinomas.METHODS Data were obtained from the electronic or paper-based medical records at The First Affiliated Hospital of Hebei North University from January 2020 to June 2022.A total of 120 patients diagnosed with EGJ carcinoma were included in the study.Of these,68 underwent laparoscopic resection after computed tomography(CT)-enhanced scanning and were categorized into the 2D group,whereas 52 underwent laparoscopic resection after CT-enhanced scanning and 3D RVT and were categorized into the 3D group.This study had two outcome measures:the deviation between tumor-related factors(such as maximum tumor diameter and infiltration length)in 3D RVT and clinical reality,and surgical outcome indicators(such as operative time,intraoperative blood loss,number of lymph node dissections,R0 resection rate,postoperative hospital stay,postoperative gas discharge time,drainage tube removal time,and related complications)between the 2D and 3D groups.RESULTS Among patients included in the 3D group,27 had a maximum tumor diameter of less than 3 cm,whereas 25 had a diameter of 3 cm or more.In actual surgical observations,24 had a diameter of less than 3 cm,whereas 28 had a diameter of 3 cm or more.The findings were consistent between the two methods(χ^(2)=0.346,P=0.556),with a kappa consistency coefficient of 0.808.With respect to infiltration length,in the 3D group,23 patients had a length of less than 5 cm,whereas 29 had a length of 5 cm or more.In actual surgical observations,20 cases had a length of less than 5 cm,whereas 32 had a length of 5 cm or more.The findings were consistent between the two methods(χ^(2)=0.357,P=0.550),with a kappa consistency coefficient of 0.486.Pearson correlation analysis showed that the maximum tumor diameter and infiltration length measured using 3D RVT were positively correlated with clinical observations during surgery(r=0.814 and 0.490,both P<0.05).The 3D group had a shorter operative time(157.02±8.38 vs 183.16±23.87),less intraoperative blood loss(83.65±14.22 vs 110.94±22.05),and higher number of lymph node dissections(28.98±2.82 vs 23.56±2.77)and R0 resection rate(80.77%vs 61.64%)than the 2D group.Furthermore,the 3D group had shorter hospital stay[8(8,9)vs 13(14,16)],time to gas passage[3(3,4)vs 4(5,5)],and drainage tube removal time[4(4,5)vs 6(6,7)]than the 2D group.The complication rate was lower in the 3D group(11.54%)than in the 2D group(26.47%)(χ^(2)=4.106,P<0.05).CONCLUSION Using 3D RVT,doctors can gain a more comprehensive and intuitive understanding of the anatomy and related lesions of EGJ carcinomas,thus enabling more accurate surgical planning. 展开更多
关键词 Gastroesophageal junction cancer ENDOSCOPY Tumor resection three-dimensional reconstruction visualization Two-dimensional imaging computed tomography
在线阅读 下载PDF
Assessment of Gastric Cancer: Value of Two-phase Multidetector-row Spiral CT Three-dimensional Reconstruction Technique 被引量:4
9
作者 李震 胡道予 +2 位作者 肖明 张进华 宋金梅 《The Chinese-German Journal of Clinical Oncology》 CAS 2005年第6期365-368,共4页
Abstract Objective: To evaluate the diagnostic value of two-phase multidetector-row spiral CT threedimensional reconstruction technique in TNM staging of gastric cancer. Methods: In 29 patients with gastric carcinom... Abstract Objective: To evaluate the diagnostic value of two-phase multidetector-row spiral CT threedimensional reconstruction technique in TNM staging of gastric cancer. Methods: In 29 patients with gastric carcinoma pathologically conformed, plan scans were done firstly. Two-phase spiral CT was performed within one breathhold each. Distension of the stomach was achieved by intravenous application of anisodamine and effervescent granules. After bolus injection of contrast medium, scanning was performed in the arterial and venous phase, and the source images were thin reconstructed. The stomach to three-dimension analysis was constructed by volume rendering (VR) multiplanaz volume reconstruction (MPVR), shaded surface display (SSD) and CT virtual gastroscopy (CTVG) technique. In combination with the sources images, gastric tumour invasion and lymph node metastasis was assessed, and TNM staging was performed. Results: In 29 cases of gastric carcinoma, the sensitivity and specificity of two-phase multidetector-row spiral CT three-dimensional reconstruction technique in T1, T2, T3 and Ta staging, the sensitivity and specificity was 50% and 50%, 87.5% and 77.8%, 83.3% and 76.9% and 100% and 80% respectively. For the N staging, the sensitivity and specificity in No, N1, and N2 N3 was 83.3% and 71.4%, 87.5% and 77.8% and 81.8% and 75% respectively. The sensitivity and the specificity for M1 staging was 100%. Conclusion: The reconstruction technique in combination with 16-slices spiral-CT can perform TNM staging well and effectively guide the choice of the surgical procedures for gastric cancer. 展开更多
关键词 SPIRAL-CT gastric carcinoma three-dimensional reconstruction
在线阅读 下载PDF
Detection and upconversion of three-dimensional MMW/THz images to the visible 被引量:3
10
作者 Avihai Aharon(Akram) Daniel Rozban +3 位作者 Avi Klein Amir Abramovich Yitzhak Yitzhaky Natan S.Kopeika 《Photonics Research》 SCIE EI 2016年第6期306-312,共7页
We present an inexpensive technique to obtain a three-dimensional(3D) millimeter wave(MMW) and terahertz(THz) image using upconversion. In this work we describe and demonstrate a method for upconversion of MMW/THz rad... We present an inexpensive technique to obtain a three-dimensional(3D) millimeter wave(MMW) and terahertz(THz) image using upconversion. In this work we describe and demonstrate a method for upconversion of MMW/THz radiation to the visual band using a very inexpensive miniature glow discharge detector(GDD) and a silicon photodetector. We present MMW/THz upconversion images based on measuring the visual light emitting from the GDD rather than its electrical current. The results show better response time and better sensitivity compared to the electronic detection performed previously. Furthermore, in this work we perform frequency modulation continuous wave(FMCW) radar detection based on this method using a GDD lamp, with a photodetector to measure GDD light emission. By using FMCW detection, the range in addition to the intensity at each pixel can be obtained,thus yielding the 3D image. The GDD acts as a heterodyne mixer not only electronically but also optically. The suggested 3D upconversion technique using the GDD is simple and inexpensive and has better performance compared to other MMW/THz imaging systems suggested in the literature. This method provides minimum detectable signal power that is about 6 orders of magnitude better than similar plasma systems due to the very large internal signal gain deriving from the much smaller electrode separation and resulting in much higher plasma electric field. 展开更多
关键词 THZ Detection and upconversion of three-dimensional MMW/THz images to the visible FMCW
原文传递
Training image analysis for three-dimensional reconstruction of porous media
11
作者 滕奇志 杨丹 +2 位作者 徐智 李征骥 何小海 《Journal of Southeast University(English Edition)》 EI CAS 2012年第4期415-421,共7页
In order to obtain a better sandstone three-dimensional (3D) reconstruction result which is more similar to the original sample, an algorithm based on stationarity for a two-dimensional (2D) training image is prop... In order to obtain a better sandstone three-dimensional (3D) reconstruction result which is more similar to the original sample, an algorithm based on stationarity for a two-dimensional (2D) training image is proposed. The second-order statistics based on texture features are analyzed to evaluate the scale stationarity of the training image. The multiple-point statistics of the training image are applied to obtain the multiple-point statistics stationarity estimation by the multi-point density function. The results show that the reconstructed 3D structures are closer to reality when the training image has better scale stationarity and multiple-point statistics stationarity by the indications of local percolation probability and two-point probability. Moreover, training images with higher multiple-point statistics stationarity and lower scale stationarity are likely to obtain closer results to the real 3D structure, and vice versa. Thus, stationarity analysis of the training image has far-reaching significance in choosing a better 2D thin section image for the 3D reconstruction of porous media. Especially, high-order statistics perform better than low-order statistics. 展开更多
关键词 three-dimensional reconstruction training image stationarity porous media multiple-point statistics
在线阅读 下载PDF
Reviews on Post-earthquake Reconstruction of Qiang Culture: Three-dimensional Pattern
12
作者 许虹 《Journal of Landscape Research》 2011年第9期11-13,18,共4页
Through the introduction of disaster situation of Qiang Culture after Wenchuan Earthquake, the paper emphasized that carriers of Qiang Culture had been seriously damaged, the inheritance of Qiang Culture had been affe... Through the introduction of disaster situation of Qiang Culture after Wenchuan Earthquake, the paper emphasized that carriers of Qiang Culture had been seriously damaged, the inheritance of Qiang Culture had been affected, and the environment for Qiang Culture was difficult to recover. It highlighted that three-dimensional reconstruction of Qiang Culture should stress the core task and timely and effectively rescue endangered cultural heritages of Qiang Nationality from the perspectives of material and spiritual life. It had explained focuses of three-dimensional pattern construction in detail. In terms of spatial reconstruction, it should reconstruct native culture and history while material culture was constructed, and reconstruct Qiang culture highland by depending on aborigines; in terms of cluster reconstruction, it should give support to large tourism enterprises and perfect tourism chain; in terms of ecological reconstruction, it should enhance construction and demonstration of "ecological protection pilot area of Qiang culture"; in terms of development reconstruction, it should realize coordinated unity between protection and development according to classification protection, characteristic protection and key protection, so as to form the virtuous circle of post-disaster recovery protection and sustainable development. 展开更多
关键词 Qiang CULTURE POST-EARTHQUAKE reconstruction three-dimensional PATTERN
在线阅读 下载PDF
Automatic three-dimensional reconstruction based on four-view stereo vision using checkerboard pattern 被引量:5
13
作者 XIONG Jie ZHONG Si-dong +1 位作者 LIU Yong TU Li-fen 《Journal of Central South University》 SCIE EI CAS CSCD 2017年第5期1063-1072,共10页
An automatic three-dimensional(3D) reconstruction method based on four-view stereo vision using checkerboard pattern is presented. Mismatches easily exist in traditional binocular stereo matching due to the repeatable... An automatic three-dimensional(3D) reconstruction method based on four-view stereo vision using checkerboard pattern is presented. Mismatches easily exist in traditional binocular stereo matching due to the repeatable or similar features of binocular images. In order to reduce the probability of mismatching and improve the measure precision, a four-camera measurement system which can add extra matching constraints and offer multiple measurements is applied in this work. Moreover, a series of different checkerboard patterns are projected onto the object to obtain dense feature points and remove mismatched points. Finally, the 3D model is generated by performing Delaunay triangulation and texture mapping on the point cloud obtained by four-view matching. This method was tested on the 3D reconstruction of a terracotta soldier sculpture and the Buddhas in the Mogao Grottoes. Their point clouds without mismatched points were obtained and less processing time was consumed in most cases relative to binocular matching. These good reconstructed models show the effectiveness of the method. 展开更多
关键词 three-dimensional reconstruction four-view STEREO VISION CHECKERBOARD pattern DENSE point
在线阅读 下载PDF
Three-dimensional reconstruction of human spinal cord based on histological serial sections 被引量:1
14
作者 Guangming Lü Huiqun Wu +3 位作者 Lemin Tang Xiao Han Dafeng Ji Xiaosong Gu 《Neural Regeneration Research》 SCIE CAS CSCD 2008年第7期697-700,共4页
BACKGROUND: It is not possible to reconstruct the inner structure of the spinal cord, such as gray matter and spinal tracts, from the Visual Human Project database or CT and MRI databases, due to low image resolution... BACKGROUND: It is not possible to reconstruct the inner structure of the spinal cord, such as gray matter and spinal tracts, from the Visual Human Project database or CT and MRI databases, due to low image resolution and contrast in macrosection images. OBJECTIVE: To explore a semi-automatic computerized three-dimensional (3D) reconstruction of human spinal cord based on histological serial sections, in order to solve issues such as low contrast. DESIGN, TIME AND SETTING: An experimental study combining serial section techniques and 3D reconstruction, performed in the laboratory of Human Anatomy and Histoembryology at the Medical School of Nantong University during January to April 2008. SETTING: Department of Anatomy, Institute of Neurobiology, Jiangsu Province Key Laboratory of Neural Regeneration, Laboratory of Image Engineering. MATERIALS: A human lumbar spinal cord segment from fresh autopsy material of an adult male. METHODS: After 4% paraformaldehyde fixation for three days, serial sections of the lumbar spinal cord were cut on a Leica cryostat and mounted on slides in sequence, with eight sections aligned separately on each slide. All sections were stained with Luxol Fast Blue to reveal myelin sheaths. After gradient dehydration and clearing, the stained slides were coverslipped. Sections were observed and images recorded under a light microscope using a digital camera. Six images were acquired at x25 magnification and automatically stitched into a complete section image. After all serial images were obtained, 96 complete serial images of the human lumbar cord segment were automatically processed with "Curves", "Autocontrast", "Gray scale 8 bit", "Invert", "Image resize to 50%" steps using Photoshop 7.0 software. All images were added in order into 3D-DOCTOR 4.0 software as a stack, where serial images were automatically realigned with neighboring images and semi-automatically segmented for white matter and gray matter. Finally, simple surface and volume reconstruction were completed on a personal computer. The reconstructed human lumbar spinal cord segment was interactively observed, cut, and measured. MAIN OUTCOME MEASURES: The reconstructed human lumbar spinal cord segment. RESULTS: Compared with serial images obtained from other image modalities, such as CT, MRI, and macrosections from The Visual Human Project database, the Luxol Fast Blue stained histological serial section images exhibited higher resolution and contrast between gray and white matter. Image processing and 3D reconstruction steps were semi-automatically performed with related software. The 3D reconstructed human lumbar cord segment were observed, cut, and measured on a PC. CONCLUSION: A semi-automatically computerized method, based on histological serial sections, is an effective way to 3D-reconstruct the human spinal cord. 展开更多
关键词 Luxol Fast Blue reconstruction serial sections surface three-dimensional visible human project VOLUME
在线阅读 下载PDF
Disagreement in middle ear volume estimation between tympanometry and three-dimensional volume reconstruction in the context of tympanic membrane perforation 被引量:2
15
作者 David J.Carpenter Debara L.Tucci +1 位作者 David M.Kaylie Dennis O.Frank-Ito 《Journal of Otology》 CSCD 2017年第2期74-79,共6页
Introduction: Middle ear volume(MEV) is a clinically relevant parameter across middle ear diseases. MEV values between these techniques have never before been tested for agreement in ears with perforated tympanic memb... Introduction: Middle ear volume(MEV) is a clinically relevant parameter across middle ear diseases. MEV values between these techniques have never before been tested for agreement in ears with perforated tympanic membranes(TMs).Methods: Middle ears were identified from 36 patients ranging 18-89 years of age with TM perforations who underwent tympanometry and temporal bone computed tomography(CT) between 2005 and 2015. MEVs calculated by both tympanometry and three-dimensional volume reconstruction(3DVR) were analyzed for agreement using Bland Altman plots. The differences between tympanometric and 3DVR MEV values for each given middle ear were characterized across MEV quartiles(1= smallest; 4= largest) and across increasing states of middle ear disease using Kruskale Wallis and Wilcoxon testing with Bonferroni correction.Results: Bland Altman plots demonstrated significant disagreement between MEV measurement techniques. Differences between tympanometric(T) and 3DVR MEV values were significantly greater with increasing average(i.e.(Tt3DVR)/2)) MEV per linear regression(p < 0.0001). Significance was demonstrated between fourth and first average MEV quartiles(p= 0.0024), fourth and second quartiles(p= 0.0024), third and first quartiles(p= 0.0048), and third and second quartiles(p= 0.048). Absolute MEV difference was not significantly different across varying states of middle ear disease(p= 0.44).Conclusion: Statistically and clinically significant disagreement was demonstrated between tympanometric and 3DVR MEV values. Studies that vary in MEV estimation techniques may be expected to demonstrate significantly different results. These preliminary results suggest that clinicians should endeavor to seek further confirmation when interpreting high tympanometric MEV values. 展开更多
关键词 Middle EAR VOLUME TYMPANOMETRY three-dimensional VOLUME reconstruction Tympanic membrane PERFORATION
在线阅读 下载PDF
Science Letters:Dynamic concision for three-dimensional reconstruction of human organ built with virtual reality modelling language (VRML) 被引量:3
16
作者 禹正杨 郑树森 +2 位作者 陈雷霆 何晓乾 王建军 《Journal of Zhejiang University-Science B(Biomedicine & Biotechnology)》 SCIE CAS CSCD 2005年第7期611-616,共6页
This research studies the process of 3D reconstruction and dynamic concision based on 2D medical digital images using virtual reality modelling language (VRML) and JavaScript language, with a focus on how to realize t... This research studies the process of 3D reconstruction and dynamic concision based on 2D medical digital images using virtual reality modelling language (VRML) and JavaScript language, with a focus on how to realize the dynamic concision of 3D medical model with script node and sensor node in VRML. The 3D reconstruction and concision of body internal organs can be built with such high quality that they are better than those obtained from the traditional methods. With the function of dynamic concision, the VRML browser can offer better windows for man-computer interaction in real-time environment than ever before. 3D reconstruction and dynamic concision with VRML can be used to meet the requirement for the medical observation of 3D reconstruction and have a promising prospect in the fields of medical imaging. 展开更多
关键词 Virtual Reality Modelling Language (VRML) Direct texture mapping three-dimensional reconstruction Dynamic concision
在线阅读 下载PDF
Three-dimensional positions of scattering centers reconstruction from multiple SAR images based on radargrammetry 被引量:3
17
作者 钟金荣 文贡坚 +1 位作者 回丙伟 李德仁 《Journal of Central South University》 SCIE EI CAS CSCD 2015年第5期1776-1789,共14页
A method and procedure is presented to reconstruct three-dimensional(3D) positions of scattering centers from multiple synthetic aperture radar(SAR) images. Firstly, two-dimensional(2D) attribute scattering centers of... A method and procedure is presented to reconstruct three-dimensional(3D) positions of scattering centers from multiple synthetic aperture radar(SAR) images. Firstly, two-dimensional(2D) attribute scattering centers of targets are extracted from 2D SAR images. Secondly, similarity measure is developed based on 2D attributed scatter centers' location, type, and radargrammetry principle between multiple SAR images. By this similarity, we can associate 2D scatter centers and then obtain candidate 3D scattering centers. Thirdly, these candidate scattering centers are clustered in 3D space to reconstruct final 3D positions. Compared with presented methods, the proposed method has a capability of describing distributed scattering center, reduces false and missing 3D scattering centers, and has fewer restrictionson modeling data. Finally, results of experiments have demonstrated the effectiveness of the proposed method. 展开更多
关键词 multiple synthetic aperture radar(SAR) images three-dimensional scattering center position reconstruction radargrammetry
在线阅读 下载PDF
GPU-accelerated three-dimensional reconstruction method of the Compton camera and its application in radionuclide imaging 被引量:1
18
作者 Ren-Yao Wu Chang-Ran Geng +6 位作者 Feng Tian Zhi-Yang Yao Chun-Hui Gong Hao-Nan Han Jian-Feng Xu Yong-Shun Xiao Xiao-Bin Tang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第4期54-68,共15页
A novel and fast three-dimensional reconstruction method for a Compton camera and its performance in radionuclide imaging is proposed and analyzed in this study. The conical surface sampling back-projection method wit... A novel and fast three-dimensional reconstruction method for a Compton camera and its performance in radionuclide imaging is proposed and analyzed in this study. The conical surface sampling back-projection method with scattering angle correction(CSS-BP-SC) can quickly perform the back-projection process of the Compton cone and can be used to precompute the list-mode maximum likelihood expectation maximization(LM-MLEM). A dedicated parallel architecture was designed for the graphics processing unit acceleration of the back-projection and iteration stage of the CSS-BP-SC-based LM-MLEM. The imaging results of the two-point source Monte Carlo(MC) simulation demonstrate that by analyzing the full width at half maximum along the three coordinate axes, the CSS-BP-SC-based LM-MLEM can obtain imaging results comparable to those of the traditional reconstruction algorithm, that is, the simple back-projection-based LM-MLEM. The imaging results of the mouse phantom MC simulation and experiment demonstrate that the reconstruction results obtained by the proposed method sufficiently coincide with the set radioactivity distribution, and the speed increased by more than 664 times compared to the traditional reconstruction algorithm in the mouse phantom experiment. The proposed method will further advance the imaging applications of Compton cameras. 展开更多
关键词 Compton camera three-dimensional reconstruction Radionuclide imaging GPU
在线阅读 下载PDF
Evaluating the contribution of satellite measurements to the reconstruction of three-dimensional ocean temperature fields in combination with Argo profiles 被引量:1
19
作者 Jian Chen Hengqian Yan +3 位作者 Senliang Bao Xindong Cui Chengzu Bai Huizan Wang 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2022年第2期65-79,共15页
Assimilation systems absorb both satellite measurements and Argo observations.This assimilation is essential to diagnose and evaluate the contribution from each type of data to the reconstructed analysis,allowing for ... Assimilation systems absorb both satellite measurements and Argo observations.This assimilation is essential to diagnose and evaluate the contribution from each type of data to the reconstructed analysis,allowing for better configuration of assimilation parameters.To achieve this,two comparative reconstruction schemes were designed under the optimal interpolation framework.Using a static scheme,an in situ-only field of ocean temperature was derived by correcting climatology with only Argo profiles.Through a dynamic scheme,a synthetic field was first derived from only satellite sea surface height and sea surface temperature measurements through vertical projection,and then a combined field was reconstructed by correcting the synthetic field with in situ profiles.For both schemes,a diagnostic iterative method was performed to optimize the background and observation error covariance statics.The root mean square difference(RMSD)of the in situ-only field,synthetic field and combined field were analyzed toward assimilated observations and independent observations,respectively.The rationale behind the distribution of RMSD was discussed using the following diagnostics:(1)The synthetic field has a smaller RMSD within the global mixed layer and extratropical deep waters,as in the Northwest Pacific Ocean;this is controlled by the explained variance of the vertical surface-underwater regression that reflects the ocean upper mixing and interior baroclinicity.(2)The in situ-only field has a smaller RMSD in the tropical upper layer and at midlatitudes;this is determined by the actual noise-to-signal ratio of ocean temperature.(3)The satellite observations make a more significant contribution to the analysis toward independent observations in the extratropics;this is determined by both the geographical feature of the synthetic field RMSD(smaller at depth in the extratropics)and that of the covariance correlation scales(smaller in the extratropics). 展开更多
关键词 satellite measurements ARGO three-dimensional reconstruction ocean temperature
在线阅读 下载PDF
Three-Dimensional Model Reconstruction of Nonwovens from Multi-Focus Images 被引量:2
20
作者 DONG Gaige WANG Rongwu +1 位作者 LI Chengzu YOU Xiangyin 《Journal of Donghua University(English Edition)》 CAS 2022年第3期185-192,共8页
The three-dimensional(3D)model is of great significance to analyze the performance of nonwovens.However,the existing modelling methods could not reconstruct the 3D structure of nonwovens at low cost.A new method based... The three-dimensional(3D)model is of great significance to analyze the performance of nonwovens.However,the existing modelling methods could not reconstruct the 3D structure of nonwovens at low cost.A new method based on deep learning was proposed to reconstruct 3D models of nonwovens from multi-focus images.A convolutional neural network was trained to extract clear fibers from sequence images.Image processing algorithms were used to obtain the radius,the central axis,and depth information of fibers from the extraction results.Based on this information,3D models were built in 3D space.Furthermore,self-developed algorithms optimized the central axis and depth of fibers,which made fibers more realistic and continuous.The method with lower cost could reconstruct 3D models of nonwovens conveniently. 展开更多
关键词 three-dimensional(3D)model reconstruction deep learning MICROSCOPY NONWOVEN image processing
在线阅读 下载PDF
上一页 1 2 13 下一页 到第
使用帮助 返回顶部