期刊文献+
共找到10,523篇文章
< 1 2 250 >
每页显示 20 50 100
GROWN-IN DEFECTS IN NATURAL BERYLS BY X-RAY TOPOGRAPHY AND BIREFRINGENCE
1
作者 JIANG Shu-sheng LI Qi 《Chinese Physics Letters》 SCIE CAS 1985年第8期341-344,共4页
The growth sectors and their boundaries,impurity zonings and dislocations in natural beryls hare been observed by means of X-ray diffraction topography and birefringence.The displacements of fault surfaces of the sect... The growth sectors and their boundaries,impurity zonings and dislocations in natural beryls hare been observed by means of X-ray diffraction topography and birefringence.The displacements of fault surfaces of the sector boundaries are perpendicular to the fault surfaces.The Burgers vectors of some typical dislocations in(0001)sector are<1120>,<1100>and<1450>.It is found that the techniques of X-ray diffraction topography and optical birefringence are complementary. 展开更多
关键词 topography FAULT COMPLEMENTARY
在线阅读 下载PDF
Substrate topography as a powerful tool to modify glial cell biology and interactions
2
作者 Pascal Achenbach Haktan Altinova Gary A.Brook 《Neural Regeneration Research》 SCIE CAS 2025年第5期1390-1391,共2页
Traumatic injuries to the central nervous system(CNS) result in disruption of the intricate network of axons which connect functionally related neurons that are widely distributed throughout the brain and spinal cord.... Traumatic injuries to the central nervous system(CNS) result in disruption of the intricate network of axons which connect functionally related neurons that are widely distributed throughout the brain and spinal cord.Under normal conditions,maintenance of this complex system is structurally and functionally supported by astrocytes (ACs)and other glial cells,the processes of which form a framework surrounding neuronal cell bodies,dendrites,axons,and synapses. 展开更多
关键词 INJURIES topography system
在线阅读 下载PDF
Investigation of bubbles escape behavior from low basicity mold flux for high-Mn high-Al steels using 3D X-ray microscope
3
作者 Qiang Liu Xiang Li +3 位作者 Shen Du Ming Gao Yanbin Yin Jiongming Zhang 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS 2025年第1期102-110,共9页
During the continuous casting process of high-Mn high-Al steels,various types of gases such as Ar need to escape through the top of the mold.In which,the behavior of bubbles traversing the liquid slag serves as a rest... During the continuous casting process of high-Mn high-Al steels,various types of gases such as Ar need to escape through the top of the mold.In which,the behavior of bubbles traversing the liquid slag serves as a restrictive link,closely associated with viscosity and the thickness of liquid slag.In contrast to two-dimensional surface observation,three-dimensional(3D)analysis method can offer a more intuitive,accurate,and comprehensive information.Therefore,this study employs a 3D X-ray microscope(3D-XRM)to obtained spatial distribution and 3D morphological characteristics of residual bubbles in mold flux under different basicity of liquid slag,different temperatures,and different holding times.The results indicate that as basicity of slag increases from 0.52 to 1.03,temperature increases from 1423 to 1573 K,the viscosity of slag decreases,the floating rate of bubbles increases.In addition,when holding time increases from 10 to 30 s,the bubbles floating distance increases,and the volume fraction and average equivalent sphere diameter of the bubbles solidified in the mold flux gradually decreases.In one word,increasing the basicity,temperature,and holding time leading to an increase in the removal rate of bubbles especially for the large.These findings of bubbles escape behavior provide valuable insights into optimizing low basicity mold flux for high-Mn high-Al steels. 展开更多
关键词 mold flux low basicity BUBBLES three-dimensional x-ray microscope VISCOSITY
在线阅读 下载PDF
Experimental Observing Damage Evolution in Cement Pastes Exposed to External Sulfate Attack by in situ X-ray Computed Tomography
4
作者 WU Min CAO Kailei +4 位作者 XIAO Weirong YU Zetai CAO Jierong DING Qingjun LI Jinhui 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2025年第1期164-170,共7页
The paper presents experimental investigation results of crack pattern change in cement pastes caused by external sulfate attack(ESA).To visualize the formation and development of cracks in cement pastes under ESA,an ... The paper presents experimental investigation results of crack pattern change in cement pastes caused by external sulfate attack(ESA).To visualize the formation and development of cracks in cement pastes under ESA,an X-ray computed tomography(X-ray CT)was used,i e,the tomography system of Zeiss Xradia 510 versa.The results indicate that X-CT can monitor the development process and distribution characteristics of the internal cracks of cement pastes under ESA with attack time.In addition,the C3A content in the cement significantly affects the damage mode of cement paste specimens during sulfate erosion.The damage of ordinary Portland cement(OPC)pastes subjected to sulfate attack with high C3A content are severe,while the damage of sulfate resistant Portland cement(SRPC)pastes is much smaller than that of OPC pastes.Furthermore,a quadratic function describes the correlation between the crack volume fraction and development depth for two cement pastes immermed in sulfate solution. 展开更多
关键词 CONCRETE external sulfate attack damage evolution situ x-ray computed tomography
在线阅读 下载PDF
Improvement of Lattice Parameter Accuracy in Single Crystal XRD Based on a Laser-Induced X-Ray Source
5
作者 LIU Jin WANG Qiannan LI Jiangtao 《高压物理学报》 北大核心 2025年第4期9-15,共7页
The lattice parameter,measured with sufficient accuracy,can be utilized to evaluate the quality of single crystals and to determine the equation of state for materials.We propose an iterative method for obtaining more... The lattice parameter,measured with sufficient accuracy,can be utilized to evaluate the quality of single crystals and to determine the equation of state for materials.We propose an iterative method for obtaining more precise lattice parameters using the interaction points for the pseudo-Kossel pattern obtained from laser-induced X-ray diffraction(XRD).This method has been validated by the analysis of an XRD experiment conducted on iron single crystals.Furthermore,the method was used to calculate the compression ratio and rotated angle of an LiF sample under high pressure loading.This technique provides a robust tool for in-situ characterization of structural changes in single crystals under extreme conditions.It has significant implications for studying the equation of state and phase transitions. 展开更多
关键词 lattice parameter measurement accuracy single crystal x-ray diffraction iterative algorithm high pressure ratio of compression
在线阅读 下载PDF
Research on the X-ray polarization deconstruction method based on hexagonal convolutional neural network
6
作者 Ya-Nan Li Jia-Huan Zhu +5 位作者 Huai-Zhong Gao Hong Li Ji-Rong Cang Zhi Zeng Hua Feng Ming Zeng 《Nuclear Science and Techniques》 2025年第2期49-61,共13页
Track reconstruction algorithms are critical for polarization measurements.Convolutional neural networks(CNNs)are a promising alternative to traditional moment-based track reconstruction approaches.However,the hexagon... Track reconstruction algorithms are critical for polarization measurements.Convolutional neural networks(CNNs)are a promising alternative to traditional moment-based track reconstruction approaches.However,the hexagonal grid track images obtained using gas pixel detectors(GPDs)for better anisotropy do not match the classical rectangle-based CNN,and converting the track images from hexagonal to square results in a loss of information.We developed a new hexagonal CNN algorithm for track reconstruction and polarization estimation in X-ray polarimeters,which was used to extract the emission angles and absorption points from photoelectron track images and predict the uncer-tainty of the predicted emission angles.The simulated data from the PolarLight test were used to train and test the hexagonal CNN models.For individual energies,the hexagonal CNN algorithm produced 15%-30%improvements in the modulation factor compared to the moment analysis method for 100%polarized data,and its performance was comparable to that of the rectangle-based CNN algorithm that was recently developed by the Imaging X-ray Polarimetry Explorer team,but at a lower computational and storage cost for preprocessing. 展开更多
关键词 x-ray polarization Track reconstruction Deep learning Hexagonal conventional neural network
在线阅读 下载PDF
Signal estimation bias in x-ray dark-field imaging using dual phase grating interferometer
7
作者 Zhi-Li Wang Zun Zhang +1 位作者 Heng Chen Xin Ge 《Chinese Physics B》 2025年第3期550-558,共9页
In x-ray dark-field imaging using dual phase grating interferometer,multi-contrast signals are extracted from a set of acquired phase-stepping data by using the least-squares fitting algorithm.The extracted mean inten... In x-ray dark-field imaging using dual phase grating interferometer,multi-contrast signals are extracted from a set of acquired phase-stepping data by using the least-squares fitting algorithm.The extracted mean intensity,amplitude and visibility signals may be intrinsically biased.However,it is still unclear how large these biases are and how the data acquisition parameters influence the biases in the extracted signals.This work set out to address these questions.Analytical expressions of the biases of the extracted signals were theoretically derived by using a second-order Taylor series expansion.Extensive numerical simulations were performed to validate the theoretical results.It is illustrated that while the estimated mean intensity signal is always unbiased,the estimated amplitude and visibility signals are both positively biased.While the biases of the estimated amplitude signals are proportional to the inverse of the total number of phase steps,the biases of the estimated visibility signals are inversely proportional to the product of the total number of phase steps and the mean number of photons counted per phase step.Meanwhile,it is demonstrated that the dependence of the biases on the mean visibility is quite different from that of Talbot-Lau interferometer due to the difference in the intensity model.We expect that these results can be useful for data acquisition optimizations and interpretation of x-ray dark-field images. 展开更多
关键词 x-ray imaging dual phase grating interferometer dark-field imaging signal bias
在线阅读 下载PDF
Microstructural evolution and hydraulic response of shale self-propped fracture using X-ray computed tomography and digital volume correlation
8
作者 Ting Huang Cheng Zhai +4 位作者 Ting Liu Yong Sun Hexiang Xu Yu Wang Jing Huang 《International Journal of Mining Science and Technology》 2025年第3期345-362,共18页
Methane in-situ explosive fracturing technology produces shale debris particles within fracture channels,enabling a self-propping effect that enhances the fracture network conductivity and long-term stability.This stu... Methane in-situ explosive fracturing technology produces shale debris particles within fracture channels,enabling a self-propping effect that enhances the fracture network conductivity and long-term stability.This study employs X-ray computed tomography(CT)and digital volume correlation(DVC)to investigate the microstructural evolution and hydromechanical responses of shale self-propped fracture under varying confining pressures,highlighting the critical role of shale particles in maintaining fracture conductivity.Results indicate that the fracture aperture in the self-propped sample is significantly larger than in the unpropped sample throughout the loading process,with shale particles tending to crush rather than embedded into the matrix,thus maintaining flow pathways.As confining pressure increases,contact areas between fracture surfaces and particles expand,enhancing the system's stability and compressive resistance.Geometric analyses show flow paths becoming increasingly concentrated and branched under high stress.This resulted in a significant reduction in connectivity,restricting fracture permeability and amplifying the nonlinear gas flow behavior.This study introduces a permeability-strain recovery zone and a novel sensitivity parameter m,delineating stress sensitivity boundaries for permeability and normal strain,with m-value increasing with stress,revealing four characteristic regions.These findings offer theoretical support for optimizing fracturing techniques to enhance resource extraction efficiency. 展开更多
关键词 Digital volume correlation x-ray CT scanning Fracture aperture Deformation characteristics Stress sensitivity Permeability
在线阅读 下载PDF
CMOS direct conversion X-ray detector coupled with fluorinated liquid
9
作者 Shi-Hua Liu Chao-Song Gao +5 位作者 Xin Zhang Xiang-Ming Sun Meng Wu Zhi-Hui Han Tong Wan Yong-Shuai Ge 《Nuclear Science and Techniques》 2025年第1期59-68,共10页
X-ray detectors show potential applications in medical imaging,materials science,and nuclear energy.To achieve high detection efficiency and spatial resolution,many conventional semiconductor materials,such as amorpho... X-ray detectors show potential applications in medical imaging,materials science,and nuclear energy.To achieve high detection efficiency and spatial resolution,many conventional semiconductor materials,such as amorphous selenium,cadmium telluride zinc,and perovskites,have been utilized in direct conversion X-ray detectors.However,these semiconductor materials are susceptible to temperature-induced performance degradation,crystallization,delamination,uneven lattice growth,radiation damage,and high dark current.This study explores a new approach by coupling an FC40 electronic fluorinated liquid with a specialized high-resolution and high-readout-speed complementary metal-oxide-semiconductor(CMOS)pixel array,specifically the Topmetal II−chip,to fabricate a direct conversion X-ray detector.The fluorinated liquid FC40(molecular formula:C_(21)F_(48)N_(2))is an electronic medium that is minimally affected by temperature and displays no issues with uniform conductivity.It exhibits a low dark current and minimal radiation damage and enables customizable thickness in X-ray absorption.This addresses the limitations inherent in conventional semiconductor-based detectors.In this study,simple X-ray detector imaging tests were conducted,demonstrating the excellent coupling capability between FC40 electronic fluorinated liquid and CMOS chips by the X-ray detector.A spatial resolution of 4.0 lp/mm was measured using a striped line par card,and a relatively clear image of a cockroach was displayed in the digital radiography imaging results.Preliminary test results indicated the feasibility of fabricating an X-ray detector by combining FC40 electronic fluorinated liquid and CMOS chips.Owing to the absence of issues related to chip-material coupling,a high spatial resolution could be achieved by reducing the chip pixel size.This method presents a new avenue for studies on novel liquid-based direct conversion X-ray detectors. 展开更多
关键词 FC40 electronic fluorinated liquid CMOS pixel chip x-ray detector Spatial resolution
在线阅读 下载PDF
Hard X-ray resonant reflectivity studies of ultrathin WS_(2) layers grown by pulsed laser deposition
10
作者 Sergey M.Suturin Polina A.Dvortsova +3 位作者 Alexander M.Korovin Vladimir V.Fedorov Evgeniya Yu.Lobanova Nikolai S.Sokolov 《Journal of Semiconductors》 2025年第3期102-108,共7页
Synchrotron method of resonant X-ray reflectivity 2D mapping has been applied to study ultrathin epitaxial layers of WS_(2)grown by pulsed laser deposition on Al_(2)O_(3)(0001)substrates.The measurements were carried ... Synchrotron method of resonant X-ray reflectivity 2D mapping has been applied to study ultrathin epitaxial layers of WS_(2)grown by pulsed laser deposition on Al_(2)O_(3)(0001)substrates.The measurements were carried out across the L absorption edge of tungsten to perform depth-dependent element-selective analysis sensitive to potential chemical modification of the WS_(2)layer in ambient conditions.Despite the few monolayer thickness of the studied film,the experimentally measured maps of reflectance as a function of incident angle and photon energy turned out to be quite informative showing well-pronounced interference effects near W absorption edge at 10210 eV.The synchrotron studies were complemented with conventional non-resonant reflectance measurements carried out in the laboratory at a fixed photon energy corresponding to Cu Kαemission.The reconstruction of the depth and energy dependent scattering length density within the studied multilayers was carried out using the OpenCL empowered fitting software utilizing spectral shaping algorithm which does not rely on the pre-measured reference absorption spectra.A thin WO_(x) layer has been revealed at the surface of the WS_(2)layer pointing out to the effect of water assisted photo-oxidation reported in a number of works related to ultrathin layers of transition metal dichalcogenides. 展开更多
关键词 transition metal dichalcogenides epitaxial multilayers pulsed layer deposition resonant x-ray reflectivity non-destructive depth profiling
在线阅读 下载PDF
X-ray Multiple Diffraction Topographic Imaging Technique For Growth History Study of Habit Modifying Impurity Doped Crystals 被引量:1
11
作者 LAI X. MA C. +1 位作者 K. J. Robert M. C. Miller 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2004年第4期411-416,共6页
A novel crystal characterization instrument has been built up in which a combination of X-ray multiple diffraction and X-ray topography is applied to enabling the cross-correlation between micro-crystallographic symme... A novel crystal characterization instrument has been built up in which a combination of X-ray multiple diffraction and X-ray topography is applied to enabling the cross-correlation between micro-crystallographic symmetry and its spatial dependence in relation to lattice defects. This facility is used to examine, in a self-consistent manner, growth sector-dependant changes to both the crystallographic structure and the lattice defects associated with the action of habit-modifying additives in a number of representative crystal growth systems. In addition, the new instrument can be used to probe micro-crystallographic aspects(such as distortion to crystal symmetry) and relate these in a spatially resolved manner to the crystal defect structure in crystals doped with known habit modifiers. 展开更多
关键词 x-ray diffraction x-ray multiple diffraction x-ray topography Habit modification Crystal growth Growth defects
在线阅读 下载PDF
X-RAY TOPOGRAPHIC STUDY OF HYDROGEN DAMAGE IN Fe-3 wt-% Si ALLOY
12
作者 WANG Yanbin WANG Anrong +1 位作者 CHU Wuyang XIAO Jimei University of Science and Technology Beijing,Beijing,China associate professor,Department of Materials Physics,University of Science and Technology Beijing,Beijing 100083,China 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 1993年第8期87-91,共5页
The formation and aggravation of hydrogen damage in Fe-3 wt-% Si alloy during cathodic charging Were studied by means of Lange transmission X-ray topography.Results showed that hydrogen damage did not form in the spe... The formation and aggravation of hydrogen damage in Fe-3 wt-% Si alloy during cathodic charging Were studied by means of Lange transmission X-ray topography.Results showed that hydrogen damage did not form in the specimens charged in 0.5 mol/L H_2S0_4 so- lution without poison,and occurred with addition of 250 mg/L As_2O_3 even at very low charge current density.As charging at a certain current density,the size of the damage may enlarge up to a limit yet no more by prolonged time.The damage size increased with increase of charging current density,but not so apparent at high current density. An external tensile stress could promote the formation of hydrogen damage obviously. It seems that for charging in H_2SO_4 solution containing poison,the drop of hydrogen permeation curve against time prolongation is due to the formation of hydrogen damages. 展开更多
关键词 hydrogen embrittlement x-ray topography Fe-3 wt-%Si alloy
在线阅读 下载PDF
High-precision X-ray characterization for basic materials in modern high-end integrated circuit
13
作者 Weiran Zhao Qiuqi Mo +3 位作者 Li Zheng Zhongliang Li Xiaowei Zhang Yuehui Yu 《Journal of Semiconductors》 EI CAS CSCD 2024年第7期12-24,共13页
Semiconductor materials exemplify humanity's unwavering pursuit of enhanced performance,efficiency,and functionality in electronic devices.From its early iterations to the advanced variants of today,this field has... Semiconductor materials exemplify humanity's unwavering pursuit of enhanced performance,efficiency,and functionality in electronic devices.From its early iterations to the advanced variants of today,this field has undergone an extraordinary evolution.As the reliability requirements of integrated circuits continue to increase,the industry is placing greater emphasis on the crystal qualities.Consequently,conducting a range of characterization tests on the crystals has become necessary.This paper will examine the correlation between crystal quality,device performance,and production yield,emphasizing the significance of crystal characterization tests and the important role of high-precision synchrotron radiation X-ray topography characterization in semiconductor analysis.Finally,we will cover the specific applications of synchrotron radiation characterization in the development of semiconductor materials. 展开更多
关键词 x-ray topography synchrotron radiation semiconductor materials crystal defects
在线阅读 下载PDF
M^(3)Res-Transformer:新冠肺炎胸部X-ray图像识别模型 被引量:3
14
作者 周涛 刘赟璨 +3 位作者 侯森宝 常晓玉 叶鑫宇 陆惠玲 《电子学报》 EI CAS CSCD 北大核心 2024年第2期589-601,共13页
新冠肺炎(COVID-19)自爆发以来严重影响人类生命健康,近年来残差神经网络广泛应用于COVID-19识别任务中,辅助医生快速地诊断COVID-19患者,但是COVID-19图像病变区域形状复杂、大小不一,与周围组织的边界模糊,导致网络难以提取有效特征.... 新冠肺炎(COVID-19)自爆发以来严重影响人类生命健康,近年来残差神经网络广泛应用于COVID-19识别任务中,辅助医生快速地诊断COVID-19患者,但是COVID-19图像病变区域形状复杂、大小不一,与周围组织的边界模糊,导致网络难以提取有效特征.本文针对上述问题,提出一种M^(3)Res-Transformer的新冠肺炎胸部X-ray图像识别模型,采用Res-Transformer作为模型的主干网络,结合ResNet和ViT,有效地整合局部病变特征和全局特征;设计混合残差注意力模块(mixed residual attention Module,mraM),同时考虑通道和空间位置的相互依赖性,增强网络的特征表达能力;为了增大感受野,提取多尺度特征,通过叠加具有不同扩张率的扩张卷积构造多尺度扩张残差模块(multiscale dilated residual Module,mdrM),根据不同层次特征尺度的差异,使用3个逐渐收缩尺度的mdrM进行多尺度特征提取;提出上下文交叉感知模块(contextual cross-awareness Module,ccaM),使用深层特征中的语义信息来引导浅层特征,然后将浅层特征中的空间信息嵌入深层特征中,采用交叉加权注意力机制高效聚合深层和浅层特征,获得更丰富的上下文信息.为了验证本文所提模型的有效性,在新冠肺炎胸部X-ray图像数据集上进行实验,与先进的CNN分类模型、融合不同注意力机制的ResNet50模型、基于Transformer的分类模型对比以及消融实验.结果表明,本文所提模型的Acc、Pre、Rec、F1-Score与Spe指标分别为96.33%、96.36%、96.33%、96.35%与96.26%,在COVID-19胸部X-ray图像识别任务中有效提升了识别精度,并通过可视化方法对其进行进一步验证,为COVID-19的辅助诊断提供重要的参考价值. 展开更多
关键词 COVID-19 胸部x-ray图像 残差神经网络 vision transformer 注意力机制
在线阅读 下载PDF
X-ray在鱼体组织及微量元素检测中的应用
15
作者 宋一帆 张胜茂 +4 位作者 张衡 唐峰华 张寒野 石永闯 崔雪森 《应用光学》 CAS 北大核心 2024年第1期166-176,共11页
鱼类硬质组织物,特别是骨骼支持鱼体和保护其体内器官的组织,对其进行特征检测分析是研究鱼类游泳运动、鱼类解剖、鱼体建模等的数据基础。随着X-ray技术的发展和国产设备的广泛应用,其仪器设备成本明显降低,使得X-ray在渔业研究与自动... 鱼类硬质组织物,特别是骨骼支持鱼体和保护其体内器官的组织,对其进行特征检测分析是研究鱼类游泳运动、鱼类解剖、鱼体建模等的数据基础。随着X-ray技术的发展和国产设备的广泛应用,其仪器设备成本明显降低,使得X-ray在渔业研究与自动化生产中的应用成为可能。首先介绍了X-ray技术的基本原理与其在鱼体组织检测中的应用,X-ray技术在鱼体组织及微量元素检测中的应用主要分为鱼类组织器官的无损检测和鱼体微量元素检测两部分,其中分别介绍了包括照相法、数字成像法、衍射技术和吸收光谱法等X-ray技术;然后综述其在鱼体组织器官建模、鱼骨检测、鱼类化石研究、鱼耳石分析和鱼体微量元素检测方面的应用,总结了Xray在渔业领域应用中存在的问题;最后对X-ray的渔业应用方向进行展望。 展开更多
关键词 x-ray 鱼体骨骼 鱼类耳石 鱼体建模 鱼体微量元素
在线阅读 下载PDF
Global hybrid simulations of soft X-ray emissions in the Earth’s magnetosheath 被引量:2
16
作者 Jin Guo TianRan Sun +6 位作者 San Lu QuanMing Lu Yu Lin XueYi Wang Chi Wang RongSheng Wang Kai Huang 《Earth and Planetary Physics》 EI CSCD 2024年第1期47-58,共12页
Earth’s magnetopause is a thin boundary separating the shocked solar wind plasma from the magnetospheric plasmas,and it is also the boundary of the solar wind energy transport to the magnetosphere.Soft X-ray imaging ... Earth’s magnetopause is a thin boundary separating the shocked solar wind plasma from the magnetospheric plasmas,and it is also the boundary of the solar wind energy transport to the magnetosphere.Soft X-ray imaging allows investigation of the large-scale magnetopause by providing a two-dimensional(2-D)global view from a satellite.By performing 3-D global hybrid-particle-in-cell(hybrid-PIC)simulations,we obtain soft X-ray images of Earth’s magnetopause under different solar wind conditions,such as different plasma densities and directions of the southward interplanetary magnetic field.In all cases,magnetic reconnection occurs at low latitude magnetopause.The soft X-ray images observed by a hypothetical satellite are shown,with all of the following identified:the boundary of the magnetopause,the cusps,and the magnetosheath.Local X-ray emissivity in the magnetosheath is characterized by large amplitude fluctuations(up to 160%);however,the maximum line-of-sight-integrated X-ray intensity matches the tangent directions of the magnetopause well,indicating that these fluctuations have limited impact on identifying the magnetopause boundary in the X-ray images.Moreover,the magnetopause boundary can be identified using multiple viewing geometries.We also find that solar wind conditions have little effect on the magnetopause identification.The Solar wind Magnetosphere Ionosphere Link Explorer(SMILE)mission will provide X-ray images of the magnetopause for the first time,and our global hybrid-PIC simulation results can help better understand the 2-D X-ray images of the magnetopause from a 3-D perspective,with particle kinetic effects considered. 展开更多
关键词 MAGNETOPAUSE x-ray emissivity x-ray imaging SMILE global hybrid-PIC simulation
在线阅读 下载PDF
The Soft X-ray Imager(SXI)on the SMILE Mission 被引量:4
17
作者 S.Sembay A.L.Alme +83 位作者 D.Agnolon T.Arnold A.Beardmore A.Belén Balado Margeli C.Bicknell C.Bouldin G.Branduardi-Raymont T.Crawford J.P.Breuer T.Buggey G.Butcher R.Canchal J.A.Carter A.Cheney Y.Collado-Vega H.Connor T.Crawford N.Eaton C.Feldman C.Forsyth T.Frantzen G.Galgóczi J.Garcia G.Y.Genov C.Gordillo H-P.Gröbelbauer M.Guedel Y.Guo M.Hailey D.Hall R.Hampson J.Hasiba O.Hetherington A.Holland S-Y.Hsieh M.W.J.Hubbard H.Jeszenszky M.Jones T.Kennedy K.Koch-Mehrin S.Kögl S.Krucker K.D.Kuntz C.Lakin G.Laky O.Lylund A.Martindale J.Miguel Mas Hesse R.Nakamura K.Oksavik N.Østgaard H.Ottacher R.Ottensamer C.Pagani S.Parsons P.Patel J.Pearson G.Peikert F.S.Porter T.Pouliantis B.H.Qureshi W.Raab G.Randal A.M.Read N.M.M.Roque M.E.Rostad C.Runciman S.Sachdev A.Samsonov M.Soman D.Sibeck S.Smit J.Søndergaard R.Speight S.Stavland M.Steller TianRan Sun J.Thornhill W.Thomas K.Ullaland B.Walsh D.Walton C.Wang S.Yang 《Earth and Planetary Physics》 EI CSCD 2024年第1期5-14,共10页
The Soft X-ray Imager(SXI)is part of the scientific payload of the Solar wind Magnetosphere Ionosphere Link Explorer(SMILE)mission.SMILE is a joint science mission between the European Space Agency(ESA)and the Chinese... The Soft X-ray Imager(SXI)is part of the scientific payload of the Solar wind Magnetosphere Ionosphere Link Explorer(SMILE)mission.SMILE is a joint science mission between the European Space Agency(ESA)and the Chinese Academy of Sciences(CAS)and is due for launch in 2025.SXI is a compact X-ray telescope with a wide field-of-view(FOV)capable of encompassing large portions of Earth’s magnetosphere from the vantage point of the SMILE orbit.SXI is sensitive to the soft X-rays produced by the Solar Wind Charge eXchange(SWCX)process produced when heavy ions of solar wind origin interact with neutral particles in Earth’s exosphere.SWCX provides a mechanism for boundary detection within the magnetosphere,such as the position of Earth’s magnetopause,because the solar wind heavy ions have a very low density in regions of closed magnetic field lines.The sensitivity of the SXI is such that it can potentially track movements of the magnetopause on timescales of a few minutes and the orbit of SMILE will enable such movements to be tracked for segments lasting many hours.SXI is led by the University of Leicester in the United Kingdom(UK)with collaborating organisations on hardware,software and science support within the UK,Europe,China and the United States. 展开更多
关键词 Soft x-ray Imaging micropore optics large area CCD
在线阅读 下载PDF
Two-Dimensional Perovskite Single Crystals for High-Performance X-ray Imaging and Exploring MeV X-ray Detection 被引量:1
18
作者 Xieming Xu Yiheng Wu +5 位作者 Yi Zhang Xiaohui Li Fang Wang Xiaoming Jiang Shaofan Wu Shuaihua Wang 《Energy & Environmental Materials》 SCIE EI CAS CSCD 2024年第1期139-146,共8页
Scintillation semiconductors play increasingly important medical diagnosis and industrial inspection roles.Recently,two-dimensional(2D)perovskites have been shown to be promising materials for medical X-ray imaging,bu... Scintillation semiconductors play increasingly important medical diagnosis and industrial inspection roles.Recently,two-dimensional(2D)perovskites have been shown to be promising materials for medical X-ray imaging,but they are mostly used in low-energy(≤130 keV)regions.Direct detection of MeV X-rays,which ensure thorough penetration of the thick shell walls of containers,trucks,and aircraft,is also highly desired in practical industrial applications.Unfortunately,scintillation semiconductors for high-energy X-ray detection are currently scarce.Here,This paper reports a 2D(C_(4)H_(9)NH_(3))_(2)PbBr_(4)single crystal with outstanding sensitivity and stability toward X-ray radiation that provides an ultra-wide detectable X-ray range of between 8.20 nGy_(air)s^(-1)(50 keV)and 15.24 mGy_(air)s^(-1)(9 MeV).The(C_(4)H_(9)NH_(3))_(2)PbBr_(4)single-crystal detector with a vertical structure is used for high-performance X-ray imaging,delivering a good spatial resolution of 4.3 Ip mm^(-1)in a plane-scan imaging system.Low ionic migration in the 2D perovskite enables the vertical device to be operated with hundreds of keV to MeV X-ray radiation at high bias voltages,leading to a sensitivity of 46.90μC Gy_(air)-1 cm^(-2)(-1.16 Vμm^(-1))with 9 MeV X-ray radiation,demonstrating that 2D perovskites have enormous potential for high-energy industrial applications. 展开更多
关键词 MeV x-ray detection single-crystal x-ray detectors two-dimensional perovskites x-ray imaging
在线阅读 下载PDF
Two methods for separating the magnetospheric solar wind charge exchange soft X-ray emission from the diffuse X-ray background 被引量:2
19
作者 YingJie Zhang TianRan Sun +5 位作者 JenniferACarter WenHao Liu Steve Sembay ShuiNai Zhang Li Ji Chi Wang 《Earth and Planetary Physics》 EI CSCD 2024年第1期119-132,共14页
Solar wind charge exchange(SWCX)is the process of solar wind high-valence ions exchanging charges with neutral components and generating soft X-rays.Recently,detecting the SWCX emission from the magnetosphere is propo... Solar wind charge exchange(SWCX)is the process of solar wind high-valence ions exchanging charges with neutral components and generating soft X-rays.Recently,detecting the SWCX emission from the magnetosphere is proposed as a new technique to study the magnetosphere using panoramic soft X-ray imaging.To better prepare for the data analysis of upcoming magnetospheric soft X-ray imaging missions,this paper compares the magnetospheric SWCX emission obtained by two methods in an XMM-Newton observation,during which the solar wind changed dramatically.The two methods differ in the data used to fit the diffuse X-ray background(DXB)parameters in spectral analysis.The method adding data from the ROSAT All-Sky Survey(RASS)is called the RASS method.The method using the quiet observation data is called the Quiet method,where quiet observations usually refer to observations made by the same satellite with the same target but under weaker solar wind conditions.Results show that the spectral compositions of magnetospheric SWCX emission obtained by the two methods are very similar,and the changes in intensity over time are highly consistent,although the intensity obtained by the RASS method is about 2.68±0.56 keV cm^(-2)s^(-1)sr^(-1)higher than that obtained by the Quiet method.Since the DXB intensity obtained by the RASS method is about 2.84±0.74 keV cm^(-2)s^(-1)sr^(-1)lower than that obtained by the Quiet method,and the linear correlation coefficient between the difference of SWCX and DXB obtained by the two methods in diffe rent energy band is close to-1,the diffe rences in magnetospheric SWCX can be fully attributed to the diffe rences in the fitted DXB.The difference between the two methods is most significant when the energy is less than 0.7 keV,which is also the main energy band of SWCX emission.In addition,the difference between the two methods is not related to the SWCX intensity and,to some extent,to solar wind conditions,because SWCX intensity typically va ries with the solar wind.In summary,both methods are robust and reliable,and should be considered based on the best available options. 展开更多
关键词 solar wind charge exchange(SWCX) ROSAT All-Sky Survey(RASS) soft x-ray x-ray imaging MAGNETOSPHERE
在线阅读 下载PDF
GNSS Technology’s Contribution to Topography: Evaluative Study of Gaps between Methods Topographies
20
作者 Cheikh Ahmed Tidiane Ly Joseph Mbagnick Louis Diene +1 位作者 Diogoye Diouf Alassane Ba 《Journal of Geographic Information System》 2021年第3期340-352,共13页
New information and communication technologies have led to the emergence of new techniques in our daily lives. Indeed, in topography, a lightning development of new techniques and new devices has been noticed. This de... New information and communication technologies have led to the emergence of new techniques in our daily lives. Indeed, in topography, a lightning development of new techniques and new devices has been noticed. This development has given rise to a multitude of choices of devices and various classes of precision. This implies that the decision-makers have to study the adequate equipment and the appropriate technique according to the topographic task to be realized. The objective is not to compare GNSS and topographic techniques, but to point out the contribution of the Global Navigation Satelite System (GNSS) techniques of topographic work. Thus, a theoretical study with a critical eye on the scientific principle of calculating the third topographic dimension followed by a leveling campaign, Real Time Kinematic (RTK) surveys will be used in order to be able to compare and interpret the result from these campaigns. The study of the difference resulting from the practical campaigns will allow us to identify the contribution of GNSS technology. 展开更多
关键词 topography GNSS Technic ACCURACY CONTRIBUTION
在线阅读 下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部