期刊文献+
共找到53,196篇文章
< 1 2 250 >
每页显示 20 50 100
Experimental Observing Damage Evolution in Cement Pastes Exposed to External Sulfate Attack by in situ X-ray Computed Tomography
1
作者 WU Min CAO Kailei +4 位作者 XIAO Weirong YU Zetai CAO Jierong DING Qingjun LI Jinhui 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2025年第1期164-170,共7页
The paper presents experimental investigation results of crack pattern change in cement pastes caused by external sulfate attack(ESA).To visualize the formation and development of cracks in cement pastes under ESA,an ... The paper presents experimental investigation results of crack pattern change in cement pastes caused by external sulfate attack(ESA).To visualize the formation and development of cracks in cement pastes under ESA,an X-ray computed tomography(X-ray CT)was used,i e,the tomography system of Zeiss Xradia 510 versa.The results indicate that X-CT can monitor the development process and distribution characteristics of the internal cracks of cement pastes under ESA with attack time.In addition,the C3A content in the cement significantly affects the damage mode of cement paste specimens during sulfate erosion.The damage of ordinary Portland cement(OPC)pastes subjected to sulfate attack with high C3A content are severe,while the damage of sulfate resistant Portland cement(SRPC)pastes is much smaller than that of OPC pastes.Furthermore,a quadratic function describes the correlation between the crack volume fraction and development depth for two cement pastes immermed in sulfate solution. 展开更多
关键词 CONCRETE external sulfate attack damage evolution situ x-ray computed tomography
在线阅读 下载PDF
A machine learning-based strategy for predicting the mechanical strength of coral reef limestone using X-ray computed tomography
2
作者 Kai Wu Qingshan Meng +4 位作者 Ruoxin Li Le Luo Qin Ke ChiWang Chenghao Ma 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2024年第7期2790-2800,共11页
Different sedimentary zones in coral reefs lead to significant anisotropy in the pore structure of coral reef limestone(CRL),making it difficult to study mechanical behaviors.With X-ray computed tomography(CT),112 CRL... Different sedimentary zones in coral reefs lead to significant anisotropy in the pore structure of coral reef limestone(CRL),making it difficult to study mechanical behaviors.With X-ray computed tomography(CT),112 CRL samples were utilized for training the support vector machine(SVM)-,random forest(RF)-,and back propagation neural network(BPNN)-based models,respectively.Simultaneously,the machine learning model was embedded into genetic algorithm(GA)for parameter optimization to effectively predict uniaxial compressive strength(UCS)of CRL.Results indicate that the BPNN model with five hidden layers presents the best training effect in the data set of CRL.The SVM-based model shows a tendency to overfitting in the training set and poor generalization ability in the testing set.The RF-based model is suitable for training CRL samples with large data.Analysis of Pearson correlation coefficient matrix and the percentage increment method of performance metrics shows that the dry density,pore structure,and porosity of CRL are strongly correlated to UCS.However,the P-wave velocity is almost uncorrelated to the UCS,which is significantly distinct from the law for homogenous geomaterials.In addition,the pore tensor proposed in this paper can effectively reflect the pore structure of coral framework limestone(CFL)and coral boulder limestone(CBL),realizing the quantitative characterization of the heterogeneity and anisotropy of pore.The pore tensor provides a feasible idea to establish the relationship between pore structure and mechanical behavior of CRL. 展开更多
关键词 Coral reef limestone(CRL) Machine learning Pore tensor x-ray computed tomography(CT)
在线阅读 下载PDF
Use of X-ray computed tomography to study structures and particle contacts of granite residual soil 被引量:16
3
作者 SUN Yin-lei TANG Lian-sheng 《Journal of Central South University》 SCIE EI CAS CSCD 2019年第4期938-954,共17页
A small problem about soil particle regularization and contacts but essential to geotechnical engineering was studied.The soils sourced from Guangzhou and Xiamen were sieved into five different particle scale ranges(d... A small problem about soil particle regularization and contacts but essential to geotechnical engineering was studied.The soils sourced from Guangzhou and Xiamen were sieved into five different particle scale ranges(d<0.075 mm,0.075 mm≤d<0.1 mm,0.1 mm≤d<0.2 mm,0.2 mm≤d<0.5 mm and 0.5 mm≤d<1.0 mm)to study the structures and particle contacts of granite residual soil.The X-ray micro computed tomography method was used to reconstruct the microstructure of granite residual soil.The particle was identified and regularized using principal component analysis(PCA).The particle contacts and geometrical characteristics in 3D space were analyzed and summarized using statistical analyses.The results demonstrate that the main types of contact among the particles are face-face,face-angle,face-edge,edge-edge,edge-angle and angle-angle contacts for particle sizes less than 0.2 mm.When the particle sizes are greater than 0.2 mm,the contacts are effectively summarized as face-face,face-angle,face-edge,edge-edge,edge-angle,angle-angle,sphere-sphere,sphere-face,sphere-edge and sphere-angle contacts.The differences in porosity among the original sample,reconstructed sample and regularized sample are closely related to the water-swelling and water-disintegrable characteristics of granite residual soil. 展开更多
关键词 x-ray computed tomography granite residual soil RECONSTRUCTION REGULARIZATION particle contact
在线阅读 下载PDF
Use of high-resolution X-ray computed tomography and 3D image analysis to quantify mineral dissemination and pore space in oxide copper ore particles 被引量:8
4
作者 Bao-hua Yang Ai-xiang Wu +2 位作者 Guillermo A.Narsilio Xiu-xiu Miao Shu-yue Wu 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2017年第9期965-973,共9页
Mineral dissemination and pore space distribution in ore particles are important features that influence heap leaching performance. To quantify the mineral dissemination and pore space distribution of an ore particle,... Mineral dissemination and pore space distribution in ore particles are important features that influence heap leaching performance. To quantify the mineral dissemination and pore space distribution of an ore particle, a cylindrical copper oxide ore sample (I center dot 4.6 mm x 5.6 mm) was scanned using high-resolution X-ray computed tomography (HRXCT), a nondestructive imaging technology, at a spatial resolution of 4.85 mu m. Combined with three-dimensional (3D) image analysis techniques, the main mineral phases and pore space were segmented and the volume fraction of each phase was calculated. In addition, the mass fraction of each mineral phase was estimated and the result was validated with that obtained using traditional techniques. Furthermore, the pore phase features, including the pore size distribution, pore surface area, pore fractal dimension, pore centerline, and the pore connectivity, were investigated quantitatively. The pore space analysis results indicate that the pore size distribution closely fits a log-normal distribution and that the pore space morphology is complicated, with a large surface area and low connectivity. This study demonstrates that the combination of HRXCT and 3D image analysis is an effective tool for acquiring 3D mineralogical and pore structural data. 展开更多
关键词 high-resolution x-ray computed tomography 3D image analysis ore particles mineral dissemination pore space
在线阅读 下载PDF
Microstructure Evolution of Sandstone Cemented by Microbe Cement Using X-ray Computed Tomography 被引量:4
5
作者 RONG Hui QIAN Chunxiang 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2013年第6期1134-1139,共6页
The bio-sandstone, which was cemented by microbe cement, was firstly prepared, and then the microstructure evolution process was studied by X-ray computed tomography (X-CT) technique. The experimental results indica... The bio-sandstone, which was cemented by microbe cement, was firstly prepared, and then the microstructure evolution process was studied by X-ray computed tomography (X-CT) technique. The experimental results indicate that the microstructure of bio-sandstone becomes dense with the development of age. The evolution of inner structure at different positions is different due to the different contents of microbial induced precipitation calcite. Besides, the increase rate of microbial induced precipitation calcite gradually decreases because of the reduction of microbe absorption content with the decreasing pore size in bio-sandstone. 展开更多
关键词 microbe cement bio-sandstone microstructure evolution x-ray computed tomography CALCITE
在线阅读 下载PDF
Quantification of 3D macropore networks in forest soils in Touzhai valley(Yunnan,China)using X-ray computed tomography and image analysis 被引量:2
6
作者 ZHANG Jia-ming XU Ze-min +2 位作者 LI Feng HOU Ru-ji REN Zhe 《Journal of Mountain Science》 SCIE CSCD 2017年第3期474-491,共18页
The three dimensional (3D) geometry of soil macropores largely controls preferential flow, which is a significant infiltrating mechanism for rainfall in forest soils and affects slope stability. However, detailed st... The three dimensional (3D) geometry of soil macropores largely controls preferential flow, which is a significant infiltrating mechanism for rainfall in forest soils and affects slope stability. However, detailed studies on the 3D geometry of macropore networks in forest soils are rare. The intense rainfall-triggered potentially unstable slopes were threatening the villages at the downstream of Touzhai valley (Yunnan, China). We visualized and quantified the 3D macropore networks in undisturbed soil columns (Histosols) taken from a forest hillslope in Touzhai valley, and compared them with those in agricultural soils (corn and soybean in USA; barley, fodder beet and red fescue in Denmark) and grassland soils in USA. We took two large undisturbed soil columns (250 mm^25o mmxsoo mm), and scanned the soil columns at in-situ soil water content conditions using X-ray computed tomography at a voxel resolution of 0.945 × 0.945 × 1.500o mm^3. After reconstruction and visualization, we quantified the characteristics of macropore networks. In the studied forest soils, the main types of maeropores were root channels, inter-aggregate voids, maeropores without knowing origin, root-soil interfaee and stone-soil interface. While maeropore networks tend to be more eomplex, larger, deeper and longer. The forest soils have high maeroporosity, total maeropore wall area density, node density, and large maeropore volume, hydraulie radius, mean maeropore length, angle, and low tortuosity. The findings suggest that maeropore networks in the forest soils have high inter- connectivity, vertical continuity, linearity and less vertically oriented. 展开更多
关键词 Slope stability Touzhai valley Rainfall infiltration Forest soils x-ray computed tomography 3D macropore networks
在线阅读 下载PDF
In situ compression and X-ray computed tomography of flow battery electrodes 被引量:1
7
作者 Rhodri Jervis Matt D.R.Kok +6 位作者 Tobias P.Neville Quentin Meyer Leon D.Brown Francesco Iacoviello Jeff T.Gostick Dan J.L.Brett Paul R.Shearing 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2018年第5期1353-1361,共9页
Redox flow batteries offer a potential solution to an increase in renewable energy generation on the grid by offering long-term, large-scale storage and regulation of power. However, they are currently un- derutilised... Redox flow batteries offer a potential solution to an increase in renewable energy generation on the grid by offering long-term, large-scale storage and regulation of power. However, they are currently un- derutilised due to cost and performance issues, many of which are linked to the microstructure of the porous carbon electrodes used. Here, for the first time, we offer a detailed study of the in situ effects of compression on a commercially available carbon felt electrode. Visualisation of electrode structure us- ing X-ray computed tomography shows the non-linear way that these materials compress and various metrics are used to elucidate the changes in porosity, pore size distribution and tortuosity factor under compressions from 0%-90%. 展开更多
关键词 Redox flow battery x-ray computed tomography Compression Carbon felt RFB
在线阅读 下载PDF
Distinct root system acclimation patterns of seagrass Zostera japonica in sediments of different trophic status:a research by X-ray computed tomography
8
作者 Xiaoyue SONG Yi ZHOU +7 位作者 Jiangning ZENG Lu SHOU Xiaomei ZHANG Shidong YUE Wei GAO Weihua FENG Zhifu WANG Ping DU 《Journal of Oceanology and Limnology》 SCIE CAS CSCD 2021年第6期2267-2280,共14页
Conspecific seagrass living in differing environments may develop different root system acclimation patterns.We applied X-ray computed tomography(CT)for imaging and quantifying roots systems of Zostera japonica collec... Conspecific seagrass living in differing environments may develop different root system acclimation patterns.We applied X-ray computed tomography(CT)for imaging and quantifying roots systems of Zostera japonica collected from typical oligotrophic and eutrophic sediments in two coastal sites of northern China,and determined sediment physicochemical properties that might influence root system morphology,density,and distribution.The trophic status of sediments had little influence on the Z.japonica root length,and diameters of root and rhizome.However,Z.japonica in oligotrophic sediment developed the root system with longer rhizome node,deeper rhizome distribution,and larger allocation to below-ground tissues in order to acquire more nutrients and relieve the N deficiency.And the lower root and rhizome densities of Z.japonica in eutrophic sediment were mainly caused by fewer shoots and shorter longevity,which was resulted from the more serious sulfide inhibition.Our results systematically revealed the effect of sediment trophic status on the phenotypic plasticity,quantity,and distribution of Z.japonica root system,and demonstrated the feasibly of X-ray CT in seagrass root system research. 展开更多
关键词 Zostera japonica root system acclimation pattern SEDIMENT trophic status x-ray computed tomography
在线阅读 下载PDF
X-ray Computed Tomography Characterization of 3D Tufted Twill Textile Composite for Aerostructures 被引量:1
9
作者 A.Saboktakin M.Shahrouz +1 位作者 T.Vu-Khanh J.Bicerano 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2019年第3期7-13,共7页
Damage assessments in three dimensional (3D) textile composites subjected to mechanical loading can be performed by non-destructive and destructive techniques.This paper applies the two techniques to investigate the f... Damage assessments in three dimensional (3D) textile composites subjected to mechanical loading can be performed by non-destructive and destructive techniques.This paper applies the two techniques to investigate the fracture behavior of 3D tufted textile composites.X-ray computed tomography as a non-destructive evaluation method is appropriate to detect damage locations and identify their progression in 3D textile composites.Destructive methods such as sectioning toward observing damage provide valuable information about damage patterns.The results of this research could be utilized to evaluate the initial cause of rupture in 3D tufted composites used in aerospace structures and analyze fracture modes and damage progression. 展开更多
关键词 x-ray computed tomography DAMAGE CHARACTERIZATION 3D composite TEXTILE PREFORM
在线阅读 下载PDF
X-Ray Computed Tomography for Root Quantification 被引量:1
10
作者 Bente Foereid 《Open Journal of Soil Science》 2015年第7期145-148,共4页
Soil cores from a field growing barley and barley mutants without root hairs under conventional and minimum tillage were sampled. They were X-ray scanned to produce a 3D image and then the roots were washed out and we... Soil cores from a field growing barley and barley mutants without root hairs under conventional and minimum tillage were sampled. They were X-ray scanned to produce a 3D image and then the roots were washed out and weight and length were determined by conventional means. Root volume and surface area were then calculated from the 3D images using state of the art software and methodology, and the measured and calculated measures were correlated. The only strong and significant correlation was between measured weight and calculated volume for mutants without root hairs. It is concluded that the software cannot segment out very small roots, but segmentation accuracy also depends on root structure in some unknown way. Any study using X-ray computed tomography to quantify roots as they grow in situ should start with a calibration for the conditions in question. 展开更多
关键词 ROOTS 3D IMAGE x-ray computed tomography
在线阅读 下载PDF
Optimization-based image reconstruction in x-ray computed tomography by sparsity exploitation of local continuity and nonlocal spatial self-similarity 被引量:1
11
作者 张瀚铭 王林元 +3 位作者 李磊 闫镔 蔡爱龙 胡国恩 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第7期557-565,共9页
The additional sparse prior of images has been the subject of much research in problems of sparse-view computed tomography(CT) reconstruction. A method employing the image gradient sparsity is often used to reduce t... The additional sparse prior of images has been the subject of much research in problems of sparse-view computed tomography(CT) reconstruction. A method employing the image gradient sparsity is often used to reduce the sampling rate and is shown to remove the unwanted artifacts while preserve sharp edges, but may cause blocky or patchy artifacts.To eliminate this drawback, we propose a novel sparsity exploitation-based model for CT image reconstruction. In the presented model, the sparse representation and sparsity exploitation of both gradient and nonlocal gradient are investigated.The new model is shown to offer the potential for better results by introducing a similarity prior information of the image structure. Then, an effective alternating direction minimization algorithm is developed to optimize the objective function with a robust convergence result. Qualitative and quantitative evaluations have been carried out both on the simulation and real data in terms of accuracy and resolution properties. The results indicate that the proposed method can be applied for achieving better image-quality potential with the theoretically expected detailed feature preservation. 展开更多
关键词 computed tomography image reconstruction sparsity exploitation nonlocal gradient
在线阅读 下载PDF
Assessment of Organ Dose by Direct and Indirect Measurements for a Wide Bore X-Ray Computed Tomography Unit That Used in Radiotherapy
12
作者 Emine Dilek Cakmak Nina Tuncel Bora Sindir 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2015年第2期132-142,共11页
The aim of this study was to investigate the organ doses of patients undergoing computed tomography (CT) examination using the wide bore General Electric (GE) “Light Speed RT” unit. The head, chest and pelvic region... The aim of this study was to investigate the organ doses of patients undergoing computed tomography (CT) examination using the wide bore General Electric (GE) “Light Speed RT” unit. The head, chest and pelvic regions of the Rando-phantom were scanned with 120 kV, 200 mA, and 2.5 mm slice thickness for helical and axial modes. Thermoluminescent Dosimeter (TLD) pairs were used for the dosimetry of 10 organs. TL-counts were converted to dose by using CTDIcenter dose on CT-phantom. For the calculation of the organ doses, the ImPACT software was utilized by entering CTDIair (100 mAs) in small and large field of view (26.43 and 21.17 mGy respectively). The in-field dose ranges in helical and axial modes were 64.3 - 38 mGy and 47.6 - 19.7 mGy in head, 48.3 - 14.1 mGy and 34.1 - 10 mGy in chest, 28.4 - 10.2 mGy and 21 - 8.5 mGy in pelvic, respectively. The organ doses from software and TLD were compared and tailored as the in-field and the out-field radiation. First results showed that the organ dose was relatively higher in the helical mode on both direct and indirect measurement. The in-field organ dose differences between TLD and software were seen. In helical and axial modes, the dose differences ranged from +1 to +13.3 and -8.3 to +9.6 mGy for head exam, +1.1 to +15.3 and +0.3 to +9.1 mGy for chest, and -21.7 to +1.9 and -15.5 to +1.8 mGy for pelvic. The availability of this program for organ dose calculations by measuring CTDIair value for CT device used in the radiotherapy would be considered valuable. 展开更多
关键词 WIDE BORE computed tomography (CT) Thermoluminescent DOSIMETER (TLD) ORGAN Dose
在线阅读 下载PDF
Combined study of Au-bearing arsenopyrite of orogenic gold deposits(NE Asia):High resolution 3D X-ray computed tomography,LA-ICP-MS,and EMPA data
13
作者 Evgeny Naumov Yuri Kalinin +4 位作者 Galina Palyanova Lyudmila Kryuchkova Viacheslav Voitenko Vera Abramova Franco Pirajno 《Geoscience Frontiers》 2025年第1期91-105,共15页
The distribution of gold in small acicular arsenopyrite of a pyrite-arsenopyrite association from Suzdal(Eastern Kazakhstan),Olympiada(Yenisei Ridge,Russia)and large pseudorhombic arsenopyrite crystals from Bazovskoe(... The distribution of gold in small acicular arsenopyrite of a pyrite-arsenopyrite association from Suzdal(Eastern Kazakhstan),Olympiada(Yenisei Ridge,Russia)and large pseudorhombic arsenopyrite crystals from Bazovskoe(Yakutia,Russia)orogenic-type deposits were investigated.On orogenic gold deposits in NE Asia,occurring mainly in black shales,two productive stages of ore deposition are distinguished,which correspond to two morphological varieties of arsenopyrite.At the early stage,fine-grained acicular-prismatic arsenopyrite with invisible gold was deposited;at the late stage,tabular arsenopyrite in association with free visible gold was formed.The samples of gold-bearing arsenopyrite were analyzed using Scanning Electron Microscopy,Electron Microprobe Analyses,Atomic Absorption and Laser Ablation Inductively Coupled Plasma Mass Spectrometry in combination with High Resolution 3D X-ray Computed Tomography(HRXCT).HRXCT does not destroy the studied mineral during the investigation.That technique permits to do an estimation of the amount of gold inclusions in minerals or host rocks and draw reasonable conclusions about the gold content of the ores,to study in detail the distribution patterns of metal inclusions(associated with certain minerals,cracks,crystal growth faces,etc.)and to determine the form of the gold.It can be used to understanding of the genesis of productive mineral associations,and to developing optimal technological schemes for gold extraction. 展开更多
关键词 High resolution 3D x-ray computed tomograph Gold-bearing arsenopyrite Suzdal at East Kazakhstan Olympiada and Bazovskoe(Russia) Orogenic gold deposits
原文传递
Experimental investigation of junction growth of rough contacts using X-ray computed tomography
14
作者 Runliang WANG Jianhua LIU +2 位作者 Bo LIU Duo JIA Xiaoyu DING 《Friction》 SCIE EI CAS CSCD 2024年第11期2519-2531,共13页
The real contact area(RCA)of randomly rough contacts has received a great deal of attention because it correlates strongly with friction,lubrication,sealing,and conductivity.Simulations have revealed that the RCA asso... The real contact area(RCA)of randomly rough contacts has received a great deal of attention because it correlates strongly with friction,lubrication,sealing,and conductivity.Simulations have revealed that the RCA associated with deterministic normal squeezing loads increases when tangential loads are also applied,in a phenomenon called junction growth.However,experimental investigations of the junction growth of randomly rough contacts are rare.Here,we used X-ray computed tomography(CT)to measure junction growth when two aluminum alloy surfaces were in contact.A high-resolution experimental setup was used to apply loads and observe contact behaviors at a resolution of 4μm.The RCA and average contact gaps were computed using a three-dimensional(3D)geometric model constructed from gray CT images using the Otsu thresholding method.The results showed that the RCA increased as the normal load increased.The RCA increased by 22.67%after a tangential load was applied(junction growth),and the average gap decreased by 14.01%after a tangential load was applied.Thus,X-ray CT accurately measured the junction growth as a novel quantitative method. 展开更多
关键词 three-dimensional(3D)contact analyses real contact area(RCA) junction growth x-ray computed tomography(CT) assembly interfaces
原文传递
Computed tomography enterography-based radiomics for assessing mucosal healing in patients with small bowel Crohn's disease
15
作者 Hao Ding Yuan-Yuan Fang +5 位作者 Wen-Jie Fan Chen-Yu Zhang Shao-Fei Wang Jing Hu Wei Han Qiao Mei 《World Journal of Gastroenterology》 SCIE CAS 2025年第3期62-72,共11页
BACKGROUND Mucosal healing(MH)is the major therapeutic target for Crohn's disease(CD).As the most commonly involved intestinal segment,small bowel(SB)assessment is crucial for CD patients.Yet,it poses a significan... BACKGROUND Mucosal healing(MH)is the major therapeutic target for Crohn's disease(CD).As the most commonly involved intestinal segment,small bowel(SB)assessment is crucial for CD patients.Yet,it poses a significant challenge due to its limited accessibility through conventional endoscopic methods.AIM To establish a noninvasive radiomic model based on computed tomography enterography(CTE)for MH assessment in SBCD patients.METHODS Seventy-three patients diagnosed with SBCD were included and divided into a training cohort(n=55)and a test cohort(n=18).Radiomic features were obtained from CTE images to establish a radiomic model.Patient demographics were analysed to establish a clinical model.A radiomic-clinical nomogram was constructed by combining significant clinical and radiomic features.The diagnostic efficacy and clinical benefit were evaluated via receiver operating characteristic(ROC)curve analysis and decision curve analysis(DCA),respectively.RESULTS Of the 73 patients enrolled,25 patients achieved MH.The radiomic-clinical nomogram had an area under the ROC curve of 0.961(95%confidence interval:0.886-1.000)in the training cohort and 0.958(0.877-1.000)in the test cohort and provided superior clinical benefit to either the clinical or radiomic models alone,as demonstrated by DCA.CONCLUSION These results indicate that the CTE-based radiomic-clinical nomogram is a promising imaging biomarker for MH and serves as a potential noninvasive alternative to enteroscopy for MH assessment in SBCD patients. 展开更多
关键词 Crohn’s disease computed tomography enterography Mucosal healing NOMOGRAM Radiomics
在线阅读 下载PDF
Role of photon-counting computed tomography in pediatric cardiovascular imaging
16
作者 Arosh S Perera Molligoda Arachchige Yash Verma 《World Journal of Clinical Pediatrics》 2025年第1期55-62,共8页
Photon-counting computed tomography(PCCT)represents a significant advancement in pediatric cardiovascular imaging.Traditional CT systems employ energy-integrating detectors that convert X-ray photons into visible ligh... Photon-counting computed tomography(PCCT)represents a significant advancement in pediatric cardiovascular imaging.Traditional CT systems employ energy-integrating detectors that convert X-ray photons into visible light,whereas PCCT utilizes photon-counting detectors that directly transform X-ray photons into electric signals.This direct conversion allows photon-counting detectors to sort photons into discrete energy levels,thereby enhancing image quality through superior noise reduction,improved spatial and contrast resolution,and reduced artifacts.In pediatric applications,PCCT offers substantial benefits,including lower radiation doses,which may help reduce the risk of malignancy in pediatric patients,with perhaps greater potential to benefit those with repeated exposure from a young age.Enhanced spatial resolution facilitates better visualization of small structures,vital for diagnosing congenital heart defects.Additionally,PCCT’s spectral capabilities improve tissue characterization and enable the creation of virtual monoenergetic images,which enhance soft-tissue contrast and potentially reduce contrast media doses.Initial clinical results indicate that PCCT provides superior image quality and diagnostic accuracy compared to conven-tional CT,particularly in challenging pediatric cardiovascular cases.As PCCT technology matures,further research and standardized protocols will be essential to fully integrate it into pediatric imaging practices,ensuring optimized diagnostic outcomes and patient safety. 展开更多
关键词 CARDIOVASCULAR Photon-counting detectors PEDIATRIC Photon-counting computed tomography computed tomography
在线阅读 下载PDF
Three-dimensional reconstruction under computed tomography and myopectineal orifice measurement under laparoscopy for quality control of inguinal hernia treatment
17
作者 Lei Zhang Jing Chen +7 位作者 Yu-Ying Zhang Lei Liu Han-Dan Wang Ya-Fei Zhang Jun Sheng Qiu-Shi Hu Ming-Liang Liu Yi-Lin Yuan 《World Journal of Gastrointestinal Endoscopy》 2025年第3期50-59,共10页
BACKGROUND Inguinal hernias are common after surgery.Tension-free repair is widely accepted as the main method for managing inguinal hernias.Adequate exposure,coverage,and repair of the myopectineal orifice(MPO)are ne... BACKGROUND Inguinal hernias are common after surgery.Tension-free repair is widely accepted as the main method for managing inguinal hernias.Adequate exposure,coverage,and repair of the myopectineal orifice(MPO)are necessary.However,due to differences in race and sex,people’s body shapes vary.According to European guidelines,the patch should measure 10 cm×15 cm.If any part of the MPO is dissected,injury to the nerves,vascular network,or organs may occur during surgery,thereby leading to inguinal discomfort,pain,and seroma formation after surgery.Therefore,accurate localization and measurement of the boundary of the MPO are crucial for selecting the optimal patch for inguinal hernia repair.AIM To compare the size of the MPO measured on three-dimensional multislice spiral computed tomography(CT)with that measured via laparoscopy and explore the relevant factors influencing the size of the MPO.METHODS Clinical data from 74 patients who underwent laparoscopic tension-free inguinal hernia repair at the General Surgery Department of the First Affiliated Hospital of Anhui University of Science and Technology between September 2022 and July 2024 were collected and analyzed retrospectively.Transabdominal preperitoneal was performed.Sixty-four males and 10 females,with an average age of 58.30±12.32 years,were included.The clinical data of the patients were collected.The boundary of the MPO was measured on three-dimensional CT images before surgery and then again during transabdominal preperitoneal.All the preoperative and intraoperative data were analyzed via paired t-tests.A t-test was used for comparisons of age,body mass index,and sex between the groups.In the comparative analysis,a P value less than 0.05 indicated a significant difference.RESULTS The boundaries of the MPO on 3-dimensional CT images measured 7.05±0.47 cm and 6.27±0.61 cm,and the area of the MPO was 19.54±3.33 cm^(2).The boundaries of the MPO during surgery were 7.18±0.51 cm and 6.17±0.40 cm.The errors were not statistically significant.However,the intraoperative BD(the width of the MPO,P=0.024,P<0.05)and preoperative AC(the length of the MPO,P=0.045,P<0.05)significantly differed according to sex.The AC and BD measurements before and during surgery were not significantly different according to age,body mass index,hernia side or hernia type(P>0.05).CONCLUSION The application of this technology can aid in determining the most appropriate dissection range and patch size. 展开更多
关键词 HERNIA INGUINAL Myopectineal orifice Three-dimensional reconstruction computed tomography Inguinal hernia
在线阅读 下载PDF
Predictive factors for liver abscess liquefaction degree based on clinical,laboratory,and computed tomography data
18
作者 Hong-Yu Long Xin Yan +1 位作者 Jia-Xian Meng Feng Xie 《World Journal of Gastrointestinal Surgery》 2025年第4期233-243,共11页
BACKGROUND Effective management of liver abscess depends on timely drainage,which is influenced by the liquefaction degree.Identifying predictive factors is crucial for guiding clinical decisions.AIM To investigate th... BACKGROUND Effective management of liver abscess depends on timely drainage,which is influenced by the liquefaction degree.Identifying predictive factors is crucial for guiding clinical decisions.AIM To investigate the predictive factors of liver abscess liquefaction and develop a predictive model to guide optimal timing of percutaneous drainage.METHODS This retrospective study included 110 patients with pyogenic liver abscesses who underwent percutaneous catheter drainage.Patients were divided into a poor liquefaction group(n=28)and a well liquefaction group(n=82)based on the ratio of postoperative 24-hour drainage volume to abscess volume,using a cutoff value of 0.3.Clinical characteristics,laboratory indicators,and computed tomography imaging features were compared.A predictive model was constructed using logistic regression and evaluated using receiver operating characteristic curves and five-fold cross-validation.RESULTS Independent predictive factors for good liquefaction included the absence of diabetes[odds ratio(OR)=0.339,P=0.044],absence of pneumonia(OR=0.218,P=0.013),left-lobe abscess location(OR=4.293,P=0.041),cystic features(OR=5.104,P=0.025),and elevated preoperative serum alanine aminotransferase(ALT)levels(OR=1.013,P=0.041).The logistic regression model based on these factors demonstrated an area under the curve of 0.814,with a sensitivity of 90.24%and specificity of 67.86%.Five-fold cross-validation yielded an average accuracy of 83.61%and a kappa coefficient of 0.5209.CONCLUSION Pneumonia,diabetes,abscess location,abscess composition,and preoperative serum ALT levels are significant predictors of liver abscess liquefaction.The model can guide clinical decision-making. 展开更多
关键词 Pyogenic liver abscess Percutaneous catheter drainage PNEUMONIA DIABETES computed tomography
在线阅读 下载PDF
In-situ X-ray computed tomography tensile tests and analysis of damage mechanism and mechanical properties in laser powder b e d fused Invar 36 alloy 被引量:1
19
作者 Qidong Yang Shuo Yang +6 位作者 Shiyu Ma Junhan Zhou Ye Zhou Rongzheng Huang Kai Wei Zhaoliang Qu Xujing Yang 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2024年第8期29-46,共18页
Laser powder bed fusion(LPBF)is a potential additive manufacturing process to manufacture Invar 36 alloy components with complicated geometry.Whereas it inevitably introduces specific microstructures and pore defects,... Laser powder bed fusion(LPBF)is a potential additive manufacturing process to manufacture Invar 36 alloy components with complicated geometry.Whereas it inevitably introduces specific microstructures and pore defects,which will further influence the mechanical properties.Hence,aiming at exploring the LPBF process-related microstructures and pore defects,and especially their influences on the damage mechanism and mechanical properties,Invar 36 alloy was manufactured by LPBF under designed different laser scanning speeds.The microstructure observations reveal that higher scanning speeds lead to equiaxed and short columnar grains with higher dislocation density,while lower scanning speeds result in elongated columnar grains with lower dislocation density.The pore defects analyzed by X-ray computed tomography(XCT)suggest that the high laser scanning speed gives rise to numerous lamellar and large lack-of-fusion(LOF)pores,and the excessively low laser scanning speed produces relatively small keyhole pores with high sphericity.Moreover,the insitu XCT tensile tests were originally performed to evaluate the damage evolution and failure mechanism.Specifically,high laser scanning speed causes brittle fracture due to the rapid growth and coalescence of initial lamellar LOF pores along the scan-ning direction.Low laser scanning speed induces ductile fracture originating from unstable depressions in the surfaces,while metallurgical and keyhole pores have little impact on damage evolution.Eventually,the process-structure-property correlation is established.The presence of high volume fraction of lamel-lar LOF pores,resulting from high scanning speed,leads to inferior yield strength and ductility.Besides,specimens without LOF pores exhibit larger grain sizes and lower dislocation density at decreased scanning speeds,slightly reducing yield strength while slightly enhancing ductility.This understanding lays the foundation for widespread applications of LPBF-processed Invar 36 alloy. 展开更多
关键词 Invar 36 alloy Laser powder bed fusion Microstructure Pore defects Mechanical property x-ray tomography in-situ tensile test
原文传递
Simultaneous fluorescence and Compton scattering computed tomography based on linear polarization X-ray
20
作者 Zhi-Jun Chi Hong-Ze Zhang +7 位作者 Jin Lin Xuan-Qi Zhang Hao Ding Qi-Li Tian Zhi Zhang Ying-Chao Du Wen-Hui Huang Chuan-Xiang Tang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第10期41-50,共10页
Purpose To propose a method for simultaneous fluorescence and Compton scattering computed tomography by using linearly polarized X-rays.Methods Monte Carlo simulations were adopted to demonstrate the feasibility of th... Purpose To propose a method for simultaneous fluorescence and Compton scattering computed tomography by using linearly polarized X-rays.Methods Monte Carlo simulations were adopted to demonstrate the feasibility of the proposed method.In the simulations,the phantom is a polytetrafluoroethylene cylinder inside which are cylindrical columns containing aluminum,water,and gold(Au)-loaded water solutions with Au concentrations ranging between 0.5 and 4.0 wt%,and a parallel-hole collimator imaging geometry was adopted.The light source was modeled based on a Thomson scattering X-ray source.The phantom images for both imaging modalities were reconstructed using a maximumlikelihood expectation maximization algorithm.Results Both the X-ray fluorescence computed tomography(XFCT)and Compton scattering computed tomography(CSCT)images of the phantom were accurately reconstructed.A similar attenuation contrast problem for the different cylindrical columns in the phantom can be resolved in the XFCT and CSCT images.The interplay between XFCT and CSCT was analyzed,and the contrast-to-noise ratio(CNR)of the reconstruction was improved by correcting for the mutual influence between the two imaging modalities.Compared with K-edge subtraction imaging,XFCT exhibits a CNR advantage for the phantom.Conclusion Simultaneous XFCT and CSCT can be realized by using linearly polarized X-rays.The synergy between the two imaging modalities would have an important application in cancer radiation therapy. 展开更多
关键词 x-ray fluorescence computed tomography Compton scattering computed tomography Linear polarization Thomson scattering x-ray source Monte Carlo simulation
在线阅读 下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部