期刊文献+
共找到9,745篇文章
< 1 2 250 >
每页显示 20 50 100
Vibration attenuation performance of wind turbine tower using a prestressed tuned mass damper under seismic excitation 被引量:1
1
作者 Lei Zhenbo Liu Gang +1 位作者 Wang Hui Hui Yi 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2024年第2期511-524,共14页
With the rapid development of large megawatt wind turbines,the operation environment of wind turbine towers(WTTs)has become increasingly complex.In particular,seismic excitation can create a resonance response and cau... With the rapid development of large megawatt wind turbines,the operation environment of wind turbine towers(WTTs)has become increasingly complex.In particular,seismic excitation can create a resonance response and cause excessive vibration of the WTT.To investigate the vibration attenuation performance of the WTT under seismic excitations,a novel passive vibration control device,called a prestressed tuned mass damper(PS-TMD),is presented in this study.First,a mathematical model is established based on structural dynamics under seismic excitation.Then,the mathematical analytical expression of the dynamic coefficient is deduced,and the parameter design method is obtained by system tuning optimization.Next,based on a theoretical analysis and parameter design,the numerical results showed that the PS-TMD was able to effectively mitigate the resonance under the harmonic basal acceleration.Finally,the time-history analysis method is used to verify the effectiveness of the traditional pendulum tuned mass damper(PTMD)and the novel PS-TMD device,and the results indicate that the vibration attenuation performance of the PS-TMD is better than the PTMD.In addition,the PS-TMD avoids the nonlinear effect due to the large oscillation angle,and has the potential to dissipate hysteretic energy under seismic excitation. 展开更多
关键词 wind turbine tower prestressed tuned mass damper vibration control seismic excitation numerical simulation
在线阅读 下载PDF
Numerical Calculation of Viscous-Elastic Fluid Flooding Residual Oil Film in the Complex Pore
2
作者 Lili Liu Chao Yu +1 位作者 Lihui Wang Lu Liu 《Open Journal of Fluid Dynamics》 2013年第3期147-151,共5页
In order to analyze the stress and deformation of different permeability of residual oil film in the complex pore, which are affected by the viscous-elasticity of the fluid, the hydrodynamic displacement mechanism is ... In order to analyze the stress and deformation of different permeability of residual oil film in the complex pore, which are affected by the viscous-elasticity of the fluid, the hydrodynamic displacement mechanism is explored from the stand-point of hydrodynamics, that is, the residual oil film displaced by alternating injection of different concentrations of the polymer solution, viscous-elastic fluid flow equation is established in the complex pore by choosing continuity equation, motion equation and the upper convected Maxwell constitutive equation. The flow field is computed by using the method of numerical analysis. Not only the stress and deformation of residual oil film on the different permeability of micro pores, but also the analysis of the flooding mechanism of alternating injection of different concentrations of the polymer solution is got. The results show that the larger the viscous-elasticity of polymer solution is, the bigger the normal deviatoric stress acting on the residual oil film is;the distribution of normal deviatoric stress has the abrupt change. The stronger the viscous-elasticity of the polymer solution is, the bigger the horizontal stress difference acting on the residual oil film is and the more obvious the deformation is;the high-concentration polymer solution is suitable for high-permeability micro pores. Low-concentration polymer solution is suitable for medium and low-permeability micro pores. Alternating injection of polymer solution can improve Volumetric Sweep Efficiency and increase the deformation of residual oil film, which is conducive to enhancing oil recovery. 展开更多
关键词 COMPLEX PORE RESIDUAL Oil Film Deformation viscous-elasticity Permeability
在线阅读 下载PDF
基于Damper的方向盘抖动问题优化设计
3
作者 葛峰 高中扩 +1 位作者 钱勇 王小飞 《汽车维修技师》 2024年第18期115-115,共1页
方向盘是顾客使用频次较高的零部件,受发动机等振源影响,在某些工况下方向盘会出现抖动等让顾客感到不适的问题,本文浅析了某车型方向盘高速抖动的原因,在现有方向盘结构上优化设计,增加Damper吸振器,有效解决了方向盘抖动问题,提升了... 方向盘是顾客使用频次较高的零部件,受发动机等振源影响,在某些工况下方向盘会出现抖动等让顾客感到不适的问题,本文浅析了某车型方向盘高速抖动的原因,在现有方向盘结构上优化设计,增加Damper吸振器,有效解决了方向盘抖动问题,提升了顾客舒适性。 展开更多
关键词 方向盘 抖动 damper吸振器 舒适性
在线阅读 下载PDF
Numerical Calculation of the Horizontal Stress Difference of Viscous-Elastic Fluid Acting on the Residual Oil in Micro Pore
4
作者 Lili Liu Shuren Yang +3 位作者 Lihui Wang Di Xu Liang Zhao Yue Cui 《Open Journal of Fluid Dynamics》 2014年第2期120-124,共5页
In order to analyze the microscopic theory of viscous-elastic fluid flooding residual oil, the flow equation of polymer solution in the micro pore can be derived by selecting upper-convected Maxwell constitutive equat... In order to analyze the microscopic theory of viscous-elastic fluid flooding residual oil, the flow equation of polymer solution in the micro pore can be derived by selecting upper-convected Maxwell constitutive equation, continuity equation and motion equation. Then, the flow velocity field and stress field can be calculated under the boundary condition, and with the theory of stress tensor, the horizontal stress difference of polymer solution acting on the residual oil can be calculated. The results show that the greater the elasticity of viscous-elastic fluid is, the wider the flow channel is, the greater the horizontal stress difference is. The force acting on residual oil by viscous-elastic fluid can be increased by increasing the concentration of the polymer solution. 展开更多
关键词 viscous-elastic FLUID Upper-Convected Maxwell CONSTITUTIVE Equation Horizontal Stress DIFFERENCE We
在线阅读 下载PDF
Mechanical Analysis of Viscous-Elastic Fluid Acting on Residual Oil in the Micro Pore
5
作者 Lili Liu Chao Yu +2 位作者 Lihui Wang Chengchuyue Fu Peixiang Li 《Open Journal of Fluid Dynamics》 2013年第4期248-251,共4页
In order to analyze the normal deviatoric stress that viscous-elastic fluid acting on the residual oil under the situation of different flooding conditions and different permeabilities, Viscous-elastic fluid flow equa... In order to analyze the normal deviatoric stress that viscous-elastic fluid acting on the residual oil under the situation of different flooding conditions and different permeabilities, Viscous-elastic fluid flow equation is established in the micro pore by choosing the continuity equation, motion equation and the upper-convected Maxwell constitutive equation, the flow field is computed by using numerical analysis, the forces that driving fluid acting on the residual oil in micro pore are got, and the influence of flooding conditions, pore width and viscous-elasticity of driving fluid on force is compared and analyzed. The results show that: the more viscous-elasticity of driving fluid increases, the greater the normal deviatoric stress acting on the residual oil increases;using constant pressure gradient flooding, the lager the pore width is, the greater normal deviatoric stress acting on the residual oil will be. 展开更多
关键词 viscous-elastic FLUID Residual Oil Normal Deviatoric Stress Micro PORE
在线阅读 下载PDF
Seismic control of multi-degrees-of-freedom structures by vertical mass isolation method using MR dampers
6
作者 Mohamad Shahrokh Abdi Masoud Nekooei Mohammad-Ali Jafari 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2024年第2期503-510,共8页
Vertical mass isolation(VMI)is one of the novel methods for the seismic control of structures.In this method,the entire structure is assumed to consist of two mass and stiffness subsystems,and an isolated layer is loc... Vertical mass isolation(VMI)is one of the novel methods for the seismic control of structures.In this method,the entire structure is assumed to consist of two mass and stiffness subsystems,and an isolated layer is located among them.In this study,the magnetorheological damper in three modes:passive-off,passive-on,and semi-active mode with variable voltage between zero and 9 volts was used as an isolated layer between two subsystems.Multi-degrees-of-freedom structures with 5,10,and 15 floors in two dimensions were examined under 11 pairs of near field earthquakes.On each level,the displacement of MR dampers was taken into account.The responses of maximum displacement,maximum inter-story drift,and maximum base shear in controlled and uncontrolled buildings were compared to assess the suggested approach for seismic control of the structures.According to the results,the semi-active control method can reduce the response by more than 12%compared to the uncontrolled mode in terms of maximum displacement of the mass subsystem of the structures.This method can reduce more than 16%and 20%of the responses compared to the uncontrolled mode in terms of maximum inter-story drift and base shear of the structure,respectively. 展开更多
关键词 seismic control vertical mass isolation base shear magnetorheological damper semi-active control
在线阅读 下载PDF
Theoretical and Experimental Study on the Performance of Hermetic Diaphragm Squeeze Film Dampers for Gas-Lubricated Bearings
7
作者 Jianwei Wang Haoxi Zhang +3 位作者 Shaocun Han Hang Li Peng Wang Kai Feng 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2024年第3期151-169,共19页
Low damping characteristics have always been a key sticking points in the development of gas bearings.The application of squeeze film dampers can significantly improve the damping performance of gas lubricated bearing... Low damping characteristics have always been a key sticking points in the development of gas bearings.The application of squeeze film dampers can significantly improve the damping performance of gas lubricated bearings.This paper proposed a novel hermetic diaphragm squeeze film damper(HDSFD)for oil-free turbomachinery supported by gas lubricated bearings.Several types of HDSFDs with symmetrical structure were proposed for good damping performance.By considering the compressibility of the damper fluid,based on hydraulic fluid mechanics theory,a dynamic model of HDSFDs under medium is proposed,which successfully reflects the frequency dependence of force coefficients.Based on the dynamic model,the effects of damper fluid viscosity,bulk modulus of damper fluid,thickness of damper fluid film and plunger thickness on the dynamic stiffness and damping of HDSFDs were analyzed.An experimental test rig was assembled and series of experimental studies on HDSFDs were conducted.The damper fluid transverse flow is added to the existing HDSFD concept,which aims to make the dynamic force coefficients independent of frequency.Although the force coefficient is still frequency dependent,the damping coefficient at high frequency excitation with damper fluid supply twice as that without damper fluid supply.The results serve as a benchmark for the calibration of analytical tools under development. 展开更多
关键词 Hermetic diaphragm squeeze film damper COMPRESSIBILITY Dynamic model Experimental studies
在线阅读 下载PDF
Development and Application of a Power Law Constitutive Model for Eddy Current Dampers
8
作者 Longteng Liang Zhouquan Feng +2 位作者 Hongyi Zhang Zhengqing Chen Changzhao Qian 《Computer Modeling in Engineering & Sciences》 SCIE EI 2024年第3期2403-2419,共17页
Eddy current dampers (ECDs) have emerged as highly desirable solutions for vibration control due to theirexceptional damping performance and durability. However, the existing constitutive models present challenges tot... Eddy current dampers (ECDs) have emerged as highly desirable solutions for vibration control due to theirexceptional damping performance and durability. However, the existing constitutive models present challenges tothe widespread implementation of ECD technology, and there is limited availability of finite element analysis (FEA)software capable of accurately modeling the behavior of ECDs. This study addresses these issues by developing anewconstitutivemodel that is both easily understandable and user-friendly for FEAsoftware. By utilizing numericalresults obtained from electromagnetic FEA, a novel power law constitutive model is proposed to capture thenonlinear behavior of ECDs. The effectiveness of the power law constitutive model is validated throughmechanicalproperty tests and numerical seismic analysis. Furthermore, a detailed description of the application process ofthe power law constitutive model in ANSYS FEA software is provided. To facilitate the preliminary design ofECDs, an analytical derivation of energy dissipation and parameter optimization for ECDs under harmonicmotionis performed. The results demonstrate that the power law constitutive model serves as a viable alternative forconducting dynamic analysis using FEA and optimizing parameters for ECDs. 展开更多
关键词 Eddy current damper constitutive model finite element analysis vibration control power law constitutive model
在线阅读 下载PDF
Parameters Optimization and Performance Evaluation of the Tuned Inerter Damper for the Seismic Protection of Adjacent Building Structures
9
作者 Xiaofang Kang Jian Wu +1 位作者 Xinqi Wang Shancheng Lei 《Computer Modeling in Engineering & Sciences》 SCIE EI 2024年第1期551-593,共43页
In order to improve the seismic performance of adjacent buildings,two types of tuned inerter damper(TID)damping systems for adjacent buildings are proposed,which are composed of springs,inerter devices and dampers in ... In order to improve the seismic performance of adjacent buildings,two types of tuned inerter damper(TID)damping systems for adjacent buildings are proposed,which are composed of springs,inerter devices and dampers in serial or in parallel.The dynamic equations of TID adjacent building damping systems were derived,and the H2 norm criterion was used to optimize and adjust them,so that the system had the optimum damping performance under white noise random excitation.Taking TID frequency ratio and damping ratio as optimization parameters,the optimum analytical solutions of the displacement frequency response of the undamped structure under white noise excitation were obtained.The results showed that compared with the classic TMD,TID could obtain a better damping effect in the adjacent buildings.Comparing the TIDs composed of serial or parallel,it was found that the parallel TIDs had more significant advantages in controlling the peak displacement frequency response,while the H2 norm of the displacement frequency response of the damping system under the coupling of serial TID was smaller.Taking the adjacent building composed of two ten-story frame structures as an example,the displacement and energy collection time history analysis of the adjacent building coupled with the optimum design parameter TIDs were carried out.It was found that TID had a better damping effect in the full-time range compared with the classic TMD.This paper also studied the potential power of TID in adjacent buildings,which can be converted into available power resources during earthquakes. 展开更多
关键词 Adjacent buildings tuned inerter damper(TID) H2 norm optimization vibration control energy harvesting
在线阅读 下载PDF
Parameter Optimization of Tuned Mass Damper Inerter via Adaptive Harmony Search
10
作者 Yaren Aydın Gebrail Bekdas +1 位作者 Sinan Melih Nigdeli Zong Woo Geem 《Computer Modeling in Engineering & Sciences》 SCIE EI 2024年第12期2471-2499,共29页
Dynamic impacts such as wind and earthquakes cause loss of life and economic damage.To ensure safety against these effects,various measures have been taken from past to present and solutions have been developed using ... Dynamic impacts such as wind and earthquakes cause loss of life and economic damage.To ensure safety against these effects,various measures have been taken from past to present and solutions have been developed using different technologies.Tall buildings are more susceptible to vibrations such as wind and earthquakes.Therefore,vibration control has become an important issue in civil engineering.This study optimizes tuned mass damper inerter(TMDI)using far-fault ground motion records.This study derives the optimum parameters of TMDI using the Adaptive Harmony Search algorithm.Structure displacement and total acceleration against earthquake load are analyzed to assess the performance of the TMDI system.The effect of the inerter when connected to different floors is observed,and the results are compared to the conventional tuned mass damper(TMD).It is indicated that the case of connecting the inerter force to the 5th floor gives better results.As a result,TMD and TMDI systems reduce the displacement by 21.87%and 25.45%,respectively,and the total acceleration by 25.45%and 19.59%,respectively.These percentage reductions indicated that the structure resilience against dynamic loads can be increased using control systems. 展开更多
关键词 Passive control optimum design parameter optimization tuned mass damper inerter time domain adaptive harmony search algorithm
在线阅读 下载PDF
Seismic Resilience Analysis of a Concrete-Framed Hospital Building with Viscous Dampers
11
作者 Yinghui Li Dongya An 《Journal of Architectural Research and Development》 2024年第6期58-62,共5页
To study the seismic resilience of a concrete-framed hospital building with viscous dampers,the elastoplastic time history analysis of a three-story concrete-framed hospital building under moderate and rare earthquake... To study the seismic resilience of a concrete-framed hospital building with viscous dampers,the elastoplastic time history analysis of a three-story concrete-framed hospital building under moderate and rare earthquakes was carried out by finite element analysis software.The structure’s overall response was studied,meanwhile,the seismic resilience of the building was evaluated from three aspects:repair cost,repair time,and casualties.The results show that viscous dampers can effectively reduce the repair cost,repair time,and casualties under earthquakes.Compared with the structure without dampers,the repair cost and repair time of the structure with dampers have been reduced by 67%and 69%respectively under moderate earthquakes,42%and 39%respectively under rare earthquakes,and the seismic resilience grade has been increased from zero to one star. 展开更多
关键词 Medical buildings Viscous dampers Seismic resilience Repair cost Repair time
在线阅读 下载PDF
Seismic Behavior Research of SRC Frame Special⁃shaped Columns with Viscous Damper
12
作者 ZANG Baijie JIN Xiangying +1 位作者 LI Xiang XIE Peng 《International Journal of Plant Engineering and Management》 2024年第4期193-212,共20页
Based on the non⁃linear finite element analysis software ETABS,a 3⁃spans of 1/2.5⁃scale of two⁃bay and three⁃story frame composed of steel reinforced concrete(SRC)special⁃shaped columns with energy dissipation devices... Based on the non⁃linear finite element analysis software ETABS,a 3⁃spans of 1/2.5⁃scale of two⁃bay and three⁃story frame composed of steel reinforced concrete(SRC)special⁃shaped columns with energy dissipation devices,and time⁃history analysis were employed to research the seismic response of the models.The results show that the seismic performance of SRC frame special⁃shaped columns with fluid viscous dampers was superior to those structures without the devices;most of the energy of the structure imposed by earthquake was dissipated by the viscous dampers.By means of analysis result,the damping parameters of the viscous dampers are optimized;the results show that the vibration damping effect of viscous dampers was sensitive to the spectral characteristics of seismic wave.These results can serve for the structure design,retrofitted design and parameter analysis of the SRC frame with special⁃shaped columns with viscous dampers. 展开更多
关键词 steel reinforced concrete(SRC) viscous damper seismic performance
在线阅读 下载PDF
串联型惯容系统多自由度结构地震响应分析
13
作者 管涛 王善库 +1 位作者 葛新广 王昌盛 《计算力学学报》 北大核心 2025年第1期130-138,共9页
研究串联型惯容系统多自由度结构随机地震响应的简明封闭解,分析了惯容系统参数及设置位置对结构减震性能的影响。首先,根据串联型惯容系统力学构造图,建立多自由度结构-惯容系统耦合地震动方程。其次,运用二次式分解法推导出建筑结构... 研究串联型惯容系统多自由度结构随机地震响应的简明封闭解,分析了惯容系统参数及设置位置对结构减震性能的影响。首先,根据串联型惯容系统力学构造图,建立多自由度结构-惯容系统耦合地震动方程。其次,运用二次式分解法推导出建筑结构节点相对于地面的绝对位移、层间节点位移及串联型惯容系统阻尼力等系列响应的0~2阶谱矩的简明封闭解。最后,通过算例,验证所提方法的正确性并研究了惯容系统参数及设置位置对结构减震性能的影响。研究表明,串联型惯容系统对结构层间位移和顶层绝对位移的减震性能具有非一致性特点;在层间位移较大的楼层设置惯容系统的布置策略是经济可行的。本文可为惯容系统实际工程应用提供参考。 展开更多
关键词 串联惯容系统 简明封闭解 二次式分解法 参数分析 阻尼器布置策略
在线阅读 下载PDF
基于性能谱设计的被动消能减震结构易损性分析
14
作者 张丽丽 韩建平 《地震工程学报》 北大核心 2025年第1期104-112,共9页
建设韧性城市的实质是实现城市灾后的可修复和自修复功能,消能减震技术为提高城市韧性、实现可持续发展提供了新思路。基于性能谱设计方法,提出一种适用于中低层框架结构的减震设计方法,将结构阻尼参数、响应及地震动参数结合起来,通过... 建设韧性城市的实质是实现城市灾后的可修复和自修复功能,消能减震技术为提高城市韧性、实现可持续发展提供了新思路。基于性能谱设计方法,提出一种适用于中低层框架结构的减震设计方法,将结构阻尼参数、响应及地震动参数结合起来,通过改变结构性能参数达到控制其响应的目的;并采用该方法对一6层Benchmark钢框架结构进行减震设计,对比分析在远场和近场有、无明显脉冲地震动记录下,减震设计前后结构不同损伤状态下的易损性。结果表明:在弹性阶段,近场非脉冲和脉冲型地震动记录下的结构响应基本一致,且略大于远场地震动记录下;在弹塑性至倒塌阶段,近场非脉冲型地震动记录下的结构响应大于远场地震动记录下;相比于远场和近场非脉冲型地震动记录,近场脉冲型地震动记录更容易引起结构的破坏甚至倒塌。基于性能谱减震设计方法设计的结构,其抗倒塌能力在远场、近场非脉冲和近场脉冲型地震动记录下分别提高了44.8%、43.8%和45.6%,进一步说明该减震设计方法受地震动记录的影响非常小。 展开更多
关键词 性能谱设计 钢框架 黏滞阻尼器 OPENSEES 易损性
在线阅读 下载PDF
速度放大型电涡流扭矩阻尼器的缓速性能研究
15
作者 华旭刚 黄豪 +3 位作者 王文熙 王帅 余天赋 陈政清 《湖南大学学报(自然科学版)》 北大核心 2025年第1期1-11,共11页
由于展开速度过快,旋转机构展开到预定形态时常引起机构与限位装置碰撞而造成损坏,如SpaceX公司生产的猎鹰9号火箭在折叠支腿展开过程中,过大转角速度可能导致支腿销铰破坏.加装阻尼器可减缓机构转速,提升展开安全性,是火箭稳定着陆的... 由于展开速度过快,旋转机构展开到预定形态时常引起机构与限位装置碰撞而造成损坏,如SpaceX公司生产的猎鹰9号火箭在折叠支腿展开过程中,过大转角速度可能导致支腿销铰破坏.加装阻尼器可减缓机构转速,提升展开安全性,是火箭稳定着陆的前提与保证.传统位移型阻尼器不具备速度适应能力,在应用于机构展开时存在展开卡死风险;而传统高压油液阻尼器在高速运作下易引发漏液造成失效.电涡流扭矩阻尼器作为一类新型的速度型阻尼器,可用于减缓机构转动角速度,具有不需外接电源、无工作流体、耐久性强等优势,但因永磁体与导体板的相对运动速度小导致其耗能效率不高,限制了其在工程中的应用.为加强传统复合管电涡流阻尼器性能,本文提出了一种磁路优化后的复合管电涡流扭矩阻尼器.相较于传统的复合管电涡流阻尼器,本文提出的阻尼器有更小的磁漏和安装体积,此外,加入齿轮增速装置提升其工作转速,进一步提升耗能性能.基于COMSOL分析软件建立了电涡流扭矩阻尼器的有限元模型,分析了空气间隙、导体管厚度、背铁厚度等参数对扭转阻尼系数的影响;同时考虑安装空间尺寸,推导了电涡流阻尼力计算公式,提出了复合管电涡流扭矩阻尼系数估算公式.制造了速度放大型电涡流扭矩阻尼器样机和展开机构原理验证装置,并进行了冲击缓速性能测试.研究结果表明,对于特定的阻尼器参数,合理地对永磁体及导体板的厚度取值,能获得较大的扭转阻尼系数;本文提出的阻尼系数估算方法能精确描述速度放大型电涡流扭矩阻尼器在阻尼线性段的力学性能;采用质量为12 kg左右的阻尼器样机可将试验展开机构在最不利工况下的最终动能耗散效率达41.6%,具有较强耗能效率优势. 展开更多
关键词 阻尼耗能 电涡流扭矩阻尼器 速度放大 缓速耗能
在线阅读 下载PDF
鼠笼弹支挤压油膜阻尼器的冲击动力学仿真与试验研究
16
作者 王晓伟 田泽辉 +3 位作者 邓旺群 聂卫健 刘文魁 张广辉 《汽轮机技术》 北大核心 2025年第2期113-118,共6页
提出了一种冲击载荷作用下鼠笼弹支挤压油膜阻尼器的动力学建模方法,并进行了冲击仿真和冲击试验研究。该方法基于短轴承理论和有限元方法,考虑冲击载荷,构建鼠笼弹支挤压油膜阻尼器的冲击动力学模型。分别考虑阻尼器供油、不供油以及... 提出了一种冲击载荷作用下鼠笼弹支挤压油膜阻尼器的动力学建模方法,并进行了冲击仿真和冲击试验研究。该方法基于短轴承理论和有限元方法,考虑冲击载荷,构建鼠笼弹支挤压油膜阻尼器的冲击动力学模型。分别考虑阻尼器供油、不供油以及冲击载荷脉宽影响,采用时域方法进行冲击动力学仿真计算。进一步设计了鼠笼弹支挤压油膜阻尼器冲击试验台,采用电动激振器模拟三角波进行冲击试验,分别在阻尼器供油、不供油以及不同冲击载荷脉宽条件下开展了冲击试验。结果表明,冲击仿真与冲击试验的最大响应变化规律一致、误差小于15%,验证了鼠笼弹支挤压油膜阻尼器冲击动力学建模方法的有效性;同时发现阻尼器在冲击过程能起到降低最大冲击响应约30%的效果,为冲击载荷下航空发动机、燃气轮机等旋转机械的鼠笼弹支挤压油膜阻尼器的抗冲击设计提供参考。 展开更多
关键词 鼠笼 挤压油膜阻尼器 冲击动力学 冲击试验
在线阅读 下载PDF
基于颗粒阻尼理论的海上风机减振甲板特性研究
17
作者 董霄峰 任绅铖 《海洋工程》 北大核心 2025年第1期74-87,共14页
当前,海上风电正朝“大容量、高塔筒、长叶片”的方向发展,在复杂海洋环境影响下,更加柔性的海上风机容易引发结构超限振动或疲劳振动问题,对海上风电场的安全运行带来严峻挑战。引入颗粒阻尼理论解决海上风机的振动控制问题。首先,充... 当前,海上风电正朝“大容量、高塔筒、长叶片”的方向发展,在复杂海洋环境影响下,更加柔性的海上风机容易引发结构超限振动或疲劳振动问题,对海上风电场的安全运行带来严峻挑战。引入颗粒阻尼理论解决海上风机的振动控制问题。首先,充分考虑风机内部空间布局与限制要求,提出了一种新型的减振颗粒甲板(VR-PD)结构形式;其次,建立了有限元与离散元(FEM-DEM)耦合的海上风机单自由度模型,并分别从颗粒的阻塞性和非阻塞性、颗粒半径和数量、腔体尺寸和颗粒叠加层数、腔体边壁倒角、颗粒质量比、结构自振周期等六方面进行VR-PD的减振特性研究;最后,建立了等质量的调谐质量阻尼器(TMD)模型,考虑急停工况、停机工况和地震工况对两者减振效果进行对比。结果显示:VR-PD最多可提升阻尼比70.6%、多降低12.9%的振动位移和9.5%的振动加速度,VR-PD不仅减振效果优于TMD,而且可以更好地适应海上风机的内部空间,具有很好的工程实用性。 展开更多
关键词 海上风电 振动控制 颗粒阻尼器 调谐质量阻尼器 FEM-DEM耦合建模
在线阅读 下载PDF
半主动碰撞耗能装置减震性能分析及优化设计研究
18
作者 鲁正 张家伟 《地震工程与工程振动》 北大核心 2025年第1期74-84,共11页
文中提出了一种具有碰撞出力时机可控的半主动碰撞耗能装置(semi-active impact damper,SAID),旨在控制地震激励下土木工程结构的多模态振动,SAID无需额外的控制元件,依靠其碰撞作动力干预结构振幅的积累实现振动控制。根据SAID力学模... 文中提出了一种具有碰撞出力时机可控的半主动碰撞耗能装置(semi-active impact damper,SAID),旨在控制地震激励下土木工程结构的多模态振动,SAID无需额外的控制元件,依靠其碰撞作动力干预结构振幅的积累实现振动控制。根据SAID力学模型和对应半主动控制策略提出了一种碰撞净距可调的装置构造,并开展了振动台试验,探究了SAID系统在5层框架结构的减震效果。研究表明,SAID系统可以有效减小结构顶层加速度和结构层间位移,依据时频能量分析可以发现SAID能够在可控碰撞中将结构的振动能量由低阶模态向高阶模态转移,从而快速耗散能量,并有效限制主导模态所引起的结构反应。本研究进一步提出了SAID系统的优化方案增强型半主动碰撞耗能装置(enhanced semi-active impact damper,ESAID)系统,以减少冲击引起的加速度突变的负面影响,同时提高SAID系统的减震性能。 展开更多
关键词 半主动碰撞耗能装置 多模态振动控制 时频能量分析 碰撞耗能装置 半主动控制
在线阅读 下载PDF
减振汲能一体化的新型机电离合惯容阻尼器
19
作者 李芦钰 赵紫阁 +2 位作者 梁启刚 张晓华 欧进萍 《地震工程与工程振动》 北大核心 2025年第1期38-50,共13页
近年来,离合惯容阻尼器(clutching inerter damper,CID)在结构振动控制中被广泛研究。由于被动CID装置未考虑飞轮速度重置并不能实现理想的分段模型,导致其控制性能受限,因此本研究探讨了CID理想模型的半主动实现。文中从理想CID模型与... 近年来,离合惯容阻尼器(clutching inerter damper,CID)在结构振动控制中被广泛研究。由于被动CID装置未考虑飞轮速度重置并不能实现理想的分段模型,导致其控制性能受限,因此本研究探讨了CID理想模型的半主动实现。文中从理想CID模型与被动CID模型的对比研究出发,深入阐述了2种模型的性能差异与局限性。随后,提出了一种汲能减振一体化的机电离合惯容阻尼器(Electromechanical clutching inerter damper,ECID)方案,给出了电惯容、飞轮速度重置与汲能功能的实施方案,建立了ECID的机电混合仿真模型。通过理论与仿真分析,深入研究了ECID的控制性能和汲能性能,探究了ECID内部电路中电阻和电容对系统性能的影响,研究表明了ECID具有显著的振动控制和能量回收能力。本研究为离合惯容器、变惯容和能量回收提供了综合方案,对自供能半主动变惯容装置的发展具有理论参考意义。 展开更多
关键词 机电离合惯容阻尼器 减振汲能一体化 半主动控制 能量回收
在线阅读 下载PDF
格构式大行程形状记忆合金限位装置研究
20
作者 李永河 王国炎 +1 位作者 党新志 曹飒飒 《地震工程与工程振动》 北大核心 2025年第1期61-73,共13页
为限制墩梁间过大的相对位移,在单根大行程形状记忆合金限位装置(long-stroke shape memory alloy restrainer,LSR)的基础上,拟提出一种基于形状记忆合金棒的格构式大行程限位装置(latticed long-stroke restrainer,LLSR)。该装置由具... 为限制墩梁间过大的相对位移,在单根大行程形状记忆合金限位装置(long-stroke shape memory alloy restrainer,LSR)的基础上,拟提出一种基于形状记忆合金棒的格构式大行程限位装置(latticed long-stroke restrainer,LLSR)。该装置由具有良好超弹性能和自复位性能的形状记忆合金(shape memory alloy,SMA)棒、MC尼龙、钢管和缀条或者缀板组成。SMA棒可消耗地震动能量并提供自复位能力;MC尼龙和钢管构成防屈曲体系,可防止SMA棒在受压时发生屈曲。首先,阐明单根大行程形状记忆合金阻尼器和格构式大行程形状记忆合金阻尼器的构造和工作机理;其次,对不同热处理温度下的SMA棒进行拉伸试验,确定超弹性能最好的SMA棒,以超弹性能最好的SMA棒作为LSR的内芯,接着开展单根LSR的轴向拉压试验,进一步研究其力学性能;最后,以LSR试验数据为基础,并且基于ABAQUS有限元软件,对LLSR进行数值分析和参数分析,以数值分析和参数分析的结果为依据提出相应的设计方法。研究表明,LLSR不仅具有稳定的耗能能力,还有良好的自复位能力。 展开更多
关键词 格构式 阻尼器 形状记忆合金 MC尼龙 试验 自复位
在线阅读 下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部