期刊文献+
共找到524篇文章
< 1 2 27 >
每页显示 20 50 100
Improved hyper-spherical search algorithm for voltage total harmonic distortion minimization in 27-level inverter
1
作者 A A KHODADOOST ARANI H KARAMI +1 位作者 B VAHIDI G B GHAREHPETIAN 《Journal of Central South University》 SCIE EI CAS CSCD 2019年第10期2822-2832,共11页
Multi-level inverters(MLIs)have become popular in different applications such as industrial power control systems and distributed generations.There are different forms of MLIs.The cascaded MLIs(CMLIs)have some special... Multi-level inverters(MLIs)have become popular in different applications such as industrial power control systems and distributed generations.There are different forms of MLIs.The cascaded MLIs(CMLIs)have some special advantages among them such as more different output voltage levels using the same number of components and higher power quality.In this paper,a 27-level inverter switching algorithm considering total harmonic distortion(THD)minimization is investigated.Switching angles of the inverter switches are achieved by minimizing a THD-based objective function.In order to minimize the THD-based objective function,the hyper-spherical search(HSS)algorithm,as a novel optimization algorithm,is improved and the results of improved HSS(IHSS)are compared with HSS algorithm and other five evolutionary algorithms to show the advantages of IHSS algorithm. 展开更多
关键词 27-level inverter cascade multi-level inverter improved hyper-spherical search(IHSS)algorithm total harmonic distortion(THD)minimization
在线阅读 下载PDF
Design and Analysis of Cascaded Hybrid-Bridge Multi-Cell Multilevel Inverter with Reduced Total Harmonic Distortion Profile
2
作者 Bulbul Sharma N.Karthick Durgesh Prasad Bagarty 《Energy Engineering》 EI 2022年第6期2585-2605,共21页
This multilevel inverter methodology is the center of focus among researchers in recent era.It has been focused due to its advantages over existing topologies,drawbacks and improvement of power quality,Multi-level inv... This multilevel inverter methodology is the center of focus among researchers in recent era.It has been focused due to its advantages over existing topologies,drawbacks and improvement of power quality,Multi-level inverter has the ability to generate nearly sinusoidal waves.This sinusoidal wave can be further improved by increasing the level of output voltage or with the help of filter design,and this manuscript presents single-phase Multi cell Multi-Level Inverter(MLI).It has been considered for reducing component count to get a higher number of output voltage levels and lower Total harmonics distortion profile.It comprises with four symmetric DC input voltage and 10 IGBT switches to produces stepped output of 9 level,and when deploy asymmetric Dc voltage source the same circuit will produce 31 level output with some changes in firing scheme,moreover this circuit is the family of cascaded hybrid bridge inverter so this circuit covered advantage of CHB MLI,This circuit uses lower no.of switch as compared to existing conventional MLIs such as FC-MLI,CHB-MLI,NPC-MLI,This paper also provides one of most pertinent controls and modulation mechanisms for a MLI using a hybrid reference/carrier-oriented sinusoidal PWM mechanism.At last,simulated outcomes are to validate the performance of both architectures in MLI structure as well as verify the concept. 展开更多
关键词 Conventional topology multi-level inverters(MLIs) pulse width modulations(PWM) reduced component counts total of harmonics distortion(THD)
在线阅读 下载PDF
HARMONIC ANALYSIS OF SINGLE-PHASE SPWM 被引量:3
3
作者 傅强 陈国雄 《Journal of Shanghai Jiaotong university(Science)》 EI 1997年第2期68-73,共6页
Based on theoretical inference and computer simulation,the relationship between the harmonics and the parameters of SPWM was widely investigated.The rule of the total harmonic distortion and the harmonic spectrum dist... Based on theoretical inference and computer simulation,the relationship between the harmonics and the parameters of SPWM was widely investigated.The rule of the total harmonic distortion and the harmonic spectrum distribution has been obtained.In order to decrease the harmonics,the selecting methods for optimal magnitude of the amplitude modularity and the frequency modularity are also given. 展开更多
关键词 SPWM harmonic SPECTRUM distribution total harmonic distortion
在线阅读 下载PDF
Online Learning Control for Harmonics Reduction Based on Current Controlled Voltage Source Power Inverters 被引量:2
4
作者 Naresh Malla Ujjwol Tamrakar +2 位作者 Dipesh Shrestha Zhen Ni Reinaldo Tonkoski 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI CSCD 2017年第3期447-457,共11页
Nonlinear loads in the power distribution system cause non-sinusoidal currents and voltages with harmonic components.Shunt active filters(SAF) with current controlled voltage source inverters(CCVSI) are usually used t... Nonlinear loads in the power distribution system cause non-sinusoidal currents and voltages with harmonic components.Shunt active filters(SAF) with current controlled voltage source inverters(CCVSI) are usually used to obtain balanced and sinusoidal source currents by injecting compensation currents.However,CCVSI with traditional controllers have a limited transient and steady state performance.In this paper,we propose an adaptive dynamic programming(ADP) controller with online learning capability to improve transient response and harmonics.The proposed controller works alongside existing proportional integral(PI) controllers to efficiently track the reference currents in the d-q domain.It can generate adaptive control actions to compensate the PI controller.The proposed system was simulated under different nonlinear(three-phase full wave rectifier) load conditions.The performance of the proposed approach was compared with the traditional approach.We have also included the simulation results without connecting the traditional PI control based power inverter for reference comparison.The online learning based ADP controller not only reduced average total harmonic distortion by 18.41%,but also outperformed traditional PI controllers during transients. 展开更多
关键词 Adaptive dynamic programming(ADP) current controlled voltage source power inverter(CCVSI) online learning based controller neural networks shunt active filter(SAF) total harmonic distortion(THD)
在线阅读 下载PDF
Analysis on Harmonics of Distribution Network with Distributed Generators 被引量:1
5
作者 Shoji Kawasaki Yasuhior Hayashi Junya Matsuki 《Journal of Energy and Power Engineering》 2012年第2期220-229,共10页
In this paper, the authors analyze the influence that connection of many distributed generators (DGs) has on the harmonics of the distribution network from the viewpoints of harmonic current, harmonic voltage, and v... In this paper, the authors analyze the influence that connection of many distributed generators (DGs) has on the harmonics of the distribution network from the viewpoints of harmonic current, harmonic voltage, and voltage total harmonic distortion (THD), when it is assumed that the harmonic voltages or the harmonic currents in a distribution network increases by connection of many DGs through the inverters. The analysis on the influence of DGs is carried out by using a standard analytical model of distribution network with DGs based on the practical data. The authors evaluate quantitatively the influence which harmonics generated from DGs has on the harmonics of the distribution network, and analyze visually about propagation of harmonics within the distribution network. In addition, the authors also verify about the restraint effect of the harmonics in the network scale by the active filters installation. 展开更多
关键词 Active filters distributed generator distribution network harmonic current harmonic voltage total harmonic distortion.
在线阅读 下载PDF
Global Harmonic Rate Assessment in the Electricity Distribution Network in Niamey City:Case Studies of Domestic,Industrial and Hospital Substations 被引量:1
6
作者 Abdourahimoun Daouda Saidou Madougou Abdoul Aziz Ibrahim 《Energy and Power Engineering》 2017年第12期786-801,共16页
Like others countries of the world, in Niger also, we are witnessing an increasing use of non-linear electric loads in the domestic, hospital and industrial sectors. However, these loads degrade the shape of the elect... Like others countries of the world, in Niger also, we are witnessing an increasing use of non-linear electric loads in the domestic, hospital and industrial sectors. However, these loads degrade the shape of the electrical signal and cause disastrous effects to the equipment of the distribution system and the devices which are connected to the network. This article highlights the presence of electric harmonics in the distribution network in Niamey city. In order to do this, measurements were taken at the secondary level of the substations using an energy quality analyze r (FLUKE 1735). By using this measuring instrument, we quantified the voltage and current Total Harmonic Distortion (THD) in the three substations. The results obtained show that, although the statutable rates set by the standards are not exceeded for phase conductors, the neutral contains a very critical percentage of distortion on the residential and hospital substations. Moreover, this assessment made it possible to observe the variation of harmonics in the presence of voltage drops. 展开更多
关键词 Electric Power Distribution Network harmonic Disturbance total harmonic distortion(THD) Power Quality Distribution Network
在线阅读 下载PDF
Harmonic Measurement and Analysis during Electric Vehicle Charging
7
作者 MohdZamriChe Wanik Mohd FadzilMohd Siam +7 位作者 Afida Ayob Subi yanto Azah Mohamed Abu HanifahAzit Saharuddin Sulaiman Mohamed Azrin Mohamed Ali Zahrul Faizi Hussein Ahmad Kamil MatHussin 《Engineering(科研)》 2013年第1期215-220,共6页
This paper presentsand describes harmonic measurement and analysis of studying harmonic propagation during electric vehicle (EV) charging. The measurement study is performed on a golf cart and two modern type of EVs. ... This paper presentsand describes harmonic measurement and analysis of studying harmonic propagation during electric vehicle (EV) charging. The measurement study is performed on a golf cart and two modern type of EVs. Harmonics from a single EV charging and a group of EV charging was measured. The voltage and current waveform during the charging was captured and analyzed to investigate the harmonic components that exist in the electrical system. Total current harmonic distortion (THDi) and total voltage harmonic distortion (THDi) were both calculated. Modern electric vehicles are found to release low THDi but higher THDv compared to a golf cart. On the measurement study during charging of? a group of EV, it is found that the summation of THD is not linear with a number of vehicles. The finding of the study reveals that harmonic contamination from EV charging on electrical grid is not as critical as thought by most of power system researchers and engineers. 展开更多
关键词 ELECTRIC VEHICLE total harmonic distortion ELECTRIC VEHICLE CHARGING harmonic Power Quality
在线阅读 下载PDF
Harmonics Extraction Scheme for Power Quality Improvement Using Chbmli-Dstatcom Module
8
作者 R.Hemalatha M.Ramasamy 《Intelligent Automation & Soft Computing》 SCIE 2023年第2期1505-1525,共21页
In recent day’s power distribution system is distress from acute power quality issues.In this work,for compensating Power Quality(PQ)disturbances a seven level cascaded H-bridge inverter is implemented in distributio... In recent day’s power distribution system is distress from acute power quality issues.In this work,for compensating Power Quality(PQ)disturbances a seven level cascaded H-bridge inverter is implemented in distribution static com-pensator which protects power quality problems in currents.Distribution Static Compensator(DSTATCOM)aid to enhances power factor and removes total har-monic distortion which is drawn from non-linear load.The D–Q reference theory based hysteresis current controller is employed to generate reference current for compensation of harmonics and reactive power,additionally Probabilistic Neural Network(PNN)classifier is used which easily separates exact harmonics.In the meantime fuzzy logic controller is also used to maintain capacitor DC-link poten-tial.When comparing to PI controller it decreases steady state time and reduces maximum peak overshoot.Cascaded H-bridge multilevel inverter converts direct current to Alternating current,through inductor opposite harmonics are injected in Power Control Centre reduces source current harmonics and reactive power.The implementation of CHBMLI in distribution STATic COMpensator simulation model is simulated by means of MATLAB. 展开更多
关键词 CHBMLI distribution STATic COMpensator(DSTATCOM) probabilistic neural network(PNN) PI(proportional–integral) fuzzy logic control(FLC) total harmonic distortion(THD)
在线阅读 下载PDF
Study on Negative Impact of Harmonic Components on Sensitive Electric Equipment
9
作者 Miroslav Dubovsky Alena Otcenasova Michal Pokorny 《Journal of Energy and Power Engineering》 2013年第4期733-739,共7页
Distribution systems operators are often confronted with declined power quality, which can cause substantial economical losses. The problem analyzed in paper concerns thyristor controlled direct current motor used for... Distribution systems operators are often confronted with declined power quality, which can cause substantial economical losses. The problem analyzed in paper concerns thyristor controlled direct current motor used for ski-lift in ski resort as a source of disturbances with negative impact on sensitive electric equipment, which is then unable to operate correctly. To solve mentioned problems, series of measurements of voltage quality parameters were carried out according to the respective valid standards. Crucial power quality parameters necessary for parallel power active filter design were then analyzed. Power active filter compensates power factor and filters characteristic current harmonics. After power active filter was put into operation, power quality problems were eliminated. Payback period is estimated up to four years. 展开更多
关键词 Power quality higher harmonics total harmonic distortion power factor power active filter sensitive electric equipment.
在线阅读 下载PDF
Total Harmonics Distortion Prediction at the Point of Common Coupling of industrial load with the grid using Artificial Neural Network 被引量:1
10
作者 Emenike Ugwuagbo Adeola Balogun +2 位作者 Biplob Ray Adnan Anwar Chikodili Ugwuishiwu 《Energy and AI》 2023年第4期294-303,共10页
Power quality challenges have generated a lot of disputes between utilities,customers,network operators,and equipment manufacturers around the world as regards the share of responsibility for power quality solutions,t... Power quality challenges have generated a lot of disputes between utilities,customers,network operators,and equipment manufacturers around the world as regards the share of responsibility for power quality solutions,this results in different levels of financial and technical losses for both the network operators and the customers.One of the major consequences of the operation of heavy-duty factories globally is the corruption of power quality at the point of common coupling(PCC).In order to quantify the harmonics contribution at the PCC by industrial consumers,this paper presents three-phase total harmonics distortion of current(THDi)prediction model at the PCC.The proposed artificial neural network(ANN)models use a multilayer perceptron neural network(MLPN)to predict three-phase total harmonic distortion.The input parameter used in the models is easily measured with basic power meters.The model was trained with input parameters captured at 33 kV and 132 kV voltage levels using power quality meters at five(5)different steel manufacturing plants.Eight(8)different models were designed,trained,validated,and tested with different combinations of input parameters,number of hidden layers,and number of neurons in the hidden layer.The results show that the model with two hidden layers which uses four major power parameters(Current,apparent power,reactive and active power)as input parameters in the training model had the best performance with a 95.5%coefficient of correlation between the measured THDi and the predicted THDi. 展开更多
关键词 total harmonics distortion(THD) Power quality(PQ) Artificial neural network(ANN)
原文传递
面向主动降噪验证的AD/DA测试平台设计
11
作者 郭振伟 周静雷 +1 位作者 付中华 李腾飞 《计算机测量与控制》 2025年第2期44-53,共10页
针对主动降噪算法程序调试难度大、相关滤波器结构可视化程度差、硬件平台底噪大的问题,设计了一款底噪小、程序可视化程度高、搭建模型简单的AD/DA硬件验证平台(AKM平台);相比较传统的ANC调试过程,AKM平台在降噪算法验证过程中不需要... 针对主动降噪算法程序调试难度大、相关滤波器结构可视化程度差、硬件平台底噪大的问题,设计了一款底噪小、程序可视化程度高、搭建模型简单的AD/DA硬件验证平台(AKM平台);相比较传统的ANC调试过程,AKM平台在降噪算法验证过程中不需要编写程序,仅需要基于Simulink HDL模块化工具搭建仿真模型,生成Bitstream文件,将其烧录到验证平台即可实现算法的验证,有效避免了开发者编写和调试程序过程的复杂性,最终实现了一款操作高效的ANC算法验证平台;实验结果表明,该系统在输入激励信号为1 kHz 100 mV,采样率为32 kHz 24 bit的条件下,测试输出信号的总谐波失真为0.005217%;信噪比为98.295 dB;在不输入任何激励信号的情况下,系统平台的底噪为5.360μVrms。 展开更多
关键词 ANC验证 ADDA平台 无需编程 总谐波失真小 低失真 底噪小
在线阅读 下载PDF
LED灯具变位系数的测量与分析
12
作者 白云高 《日用电器》 2025年第2期82-85,共4页
功率因数是LED灯具的重要参数之一,但随着IEC在LED模块和LED灯具标准中用变位系数取代功率因数,国内相应的LED产品标准也开始用变位系数取代功率因数。本文根据标准中的定义及要求,用已有检测设备对LED灯具的变位系数进行测量和计算,来... 功率因数是LED灯具的重要参数之一,但随着IEC在LED模块和LED灯具标准中用变位系数取代功率因数,国内相应的LED产品标准也开始用变位系数取代功率因数。本文根据标准中的定义及要求,用已有检测设备对LED灯具的变位系数进行测量和计算,来阐述变位系数的规律和物理意义。 展开更多
关键词 LED灯具 变位系数 位移因数 功率因数 失真系数 总谐波畸变率
在线阅读 下载PDF
The Use of LMS and RLS Adaptive Algorithms for an Adaptive Control Method of Active Power Filter 被引量:2
13
作者 Radek Martinek Jan Zidek +4 位作者 Petr Bilik Jakub Manas Jiri Koziorek Zhaosheng Teng He Wen 《Energy and Power Engineering》 2013年第4期1126-1133,共8页
This paper deals with the adaptive control mechanism management meant for shunt active power filters (SAPF). Systems driven this way are designed to improve the quality of electric power (power quality) in industrial ... This paper deals with the adaptive control mechanism management meant for shunt active power filters (SAPF). Systems driven this way are designed to improve the quality of electric power (power quality) in industrial networks. The authors have focused on the implementation of two basic representatives of adaptive algorithms, first, the algorithm with a stochastic LMS (least mean square) gradient adaptation and then an algorithm with recursive RLS (recursive least square) optimal adaptation. The system examined by the authors can be used for non-linear loads for appliances with rapid fluctuations of the reactive and active power consumption. The proposed system adaptively reduces distortion, falls (dip) and changes in a supply voltage (flicker). Real signals for measurement were obtained at a sophisticated, three-phase experimental workplace. The results of executed experiments indicate that, with use of the certain adaptive algorithms, the examined AHC system shows very good dynamics, resulting in a much faster transition during the AHC connection-disconnection or during a change in harmonic load on the network. The actual experiments are evaluated from several points of view, mainly according to a time convergence (convergence time) and mistakes in a stable state error (steady state error) of the investigated adaptive algorithms and finally as a total harmonic distortion (THD). The article presents a comparison of the most frequently used adaptive algorithms. 展开更多
关键词 Active Power Filters total harmonic distortion Least Mean SQUARE Adaptive Filtering RECURSIVE Least SQUARE
在线阅读 下载PDF
Power-Sharing Enhancement Using Harmonized Membership Fuzzy Logic Droop Control Based Micro-Grid 被引量:1
14
作者 W.J.Praiselin J.Belwin Edward 《Intelligent Automation & Soft Computing》 SCIE 2023年第5期1395-1415,共21页
The contribution of Renewable Energy Resources(RER)in the process of power generation is significantly high in the recent days since it paves the way for overcoming the issues like serious energy crisis and natural con... The contribution of Renewable Energy Resources(RER)in the process of power generation is significantly high in the recent days since it paves the way for overcoming the issues like serious energy crisis and natural contamination.This paper deals with the renewable energy based micro-grid as it is regarded as the apt solution for integrating the RER with the electrical frameworks.As thefixed droop coefficients in conventional droop control approaches have caused various limitations like low power-sharing and sudden drops of grid voltage in the Direct Current(DC)side,the Harmonized Membership Fuzzy Logic(MFL)droop control is employed in this present study.This proposed droop control for the hybrid PV-wind-battery system with MFL assists in achieving proper power-sharing and minimizing Total Harmonic Distortion(THD)in the emer-gency micro-grid.It eradicates the deviations in voltage and frequency with itsflexible and robust operation.The THD is reduced and attains the value of 3.1%compared to the traditional droop control.The simulation results of harmo-nized MFL droop control are analogized with the conventional approaches to vali-date the performance of the proposed method.In addition,the experimental results provided by the Field Programmable Gate Array(FPGA)based laboratory setup built using a solar photovoltaic(PV)and wind Permanent Magnet Synchro-nous Generator(PMSG)reaffirms the design. 展开更多
关键词 MICRO-GRID harmonized droop control fuzzy POWER-SHARING total harmonic distortion
在线阅读 下载PDF
基于模拟开关的放大器非线性失真电路设计
15
作者 吴晓盼 《黄山学院学报》 2024年第5期26-30,共5页
非线性失真是影响模拟电路性能的重要因素之一,针对顶部失真、底部失真、双向失真和交越失真四种非线性失真情况对晶体管放大电路的影响,在详细介绍非线性失真原因及总谐波失真量化评价的基础上,以STM32F103ZET6单片机为核心,设计制作... 非线性失真是影响模拟电路性能的重要因素之一,针对顶部失真、底部失真、双向失真和交越失真四种非线性失真情况对晶体管放大电路的影响,在详细介绍非线性失真原因及总谐波失真量化评价的基础上,以STM32F103ZET6单片机为核心,设计制作了一个放大器非线性失真研究装置。该装置主要包括晶体管放大器、采集测量、微控制器等硬件电路和软件驱动。通过两级负反馈共射放大、乙类放大分别实现基本晶体管放大和四种非线性失真产生电路,利用BL1551和CD4053模拟开关控制波形输出,采用FFT算法提取总谐波失真值。经系统测试:所设计的装置可以输出不失真波形、四种非线性失真电压波形和测量显示总谐波失真系数;测试外接信号源指定信号的总谐波失真系数时,平均精度可达95%。 展开更多
关键词 非线性失真 晶体管 放大器 模拟开关 总谐波失真
在线阅读 下载PDF
基于改进变步长LMS算法的谐波电流检测法
16
作者 曹珍贯 方金明 董高辉 《佳木斯大学学报(自然科学版)》 CAS 2024年第4期19-23,共5页
针对传统基于瞬时无功功率理论谐波电流检测中的二阶低通滤波器无法同时满足检测精度和响应时间的问题,提出了基于改进的双曲正切函数变步长LMS算法(IVSSLMS)的低通滤波器提取p轴和q轴中直流分量的方法;将两个谐波电流的间隔时间通过适... 针对传统基于瞬时无功功率理论谐波电流检测中的二阶低通滤波器无法同时满足检测精度和响应时间的问题,提出了基于改进的双曲正切函数变步长LMS算法(IVSSLMS)的低通滤波器提取p轴和q轴中直流分量的方法;将两个谐波电流的间隔时间通过适当的调节采样间隔次数来延长,目的是为了达到高次谐波的自相关性能迅速降为零。从理论上分析了算法性能的优越,给出了参数的取值,并在simulink中搭建了仿真模型,仿真实验结果表明,改进后的低通滤波器直流分量的跟踪速度提升了一倍,得到基波正弦波形的THD值下降了0.37%。并得出以下结论:在同样输电条件下,采用改进变步长LMS算法构成低通滤波器加快了直流量的跟踪,提取的基波分量更加接近于理想波形,提升了谐波检测的瞬时性和准确性。 展开更多
关键词 瞬时无功理论 LMS算法 谐波总畸变率
在线阅读 下载PDF
适用于三电平逆变器的电流谐波最小脉宽调制策略 被引量:1
17
作者 褚艳红 周明磊 +1 位作者 王琛琛 游小杰 《电机与控制学报》 EI CSCD 北大核心 2024年第8期21-30,共10页
受限于散热条件,大功率牵引传动系统中逆变器开关频率通常很低,三电平逆变器由于在低开关频率下具有较小的输出谐波、较低的dv/dt等特点在中高压大功率领域中被广泛应用。以三电平中点钳位型逆变器为研究对象,提出一种电流谐波最小脉宽... 受限于散热条件,大功率牵引传动系统中逆变器开关频率通常很低,三电平逆变器由于在低开关频率下具有较小的输出谐波、较低的dv/dt等特点在中高压大功率领域中被广泛应用。以三电平中点钳位型逆变器为研究对象,提出一种电流谐波最小脉宽调制策略(CHMPWM),基于加权总谐波畸变最小的优化目标求解不同开关角个数下的开关角曲线,与目前应用较为广泛的特定次谐波消除脉宽调制进行谐波性能对比。该方法不会完全消除特定次数的谐波成分,但是总体电流谐波可以达到最小。针对电流谐波最小脉宽调制策略在实现过程中存在的困难,设计全速度范围基于电流谐波最小脉宽调制的多模式调制策略。仿真和实验结果表明,提出的调制策略具有良好的谐波性能,与理论分析结果一致。 展开更多
关键词 三电平逆变器 电流谐波最小 脉宽调制 低开关频率 加权总谐波畸变 谐波性能
在线阅读 下载PDF
基于STM32单片机的音响品质测试仪 被引量:1
18
作者 刁楚涵 王艳 +2 位作者 陈敏杰 付山峰 林书乐 《电子器件》 CAS 2024年第4期935-940,共6页
基于STM32F407VET6单片机,设计出一款能够测试音响设备失真度、频响范围等参数的音响品质测试仪。该装置采用锂电池,配合降压电路进行供电,利用拾音电路采集声音信号,借助外置16位A/D模块进行信号的ADC采样,通过FFT算法对声音信号进行分... 基于STM32F407VET6单片机,设计出一款能够测试音响设备失真度、频响范围等参数的音响品质测试仪。该装置采用锂电池,配合降压电路进行供电,利用拾音电路采集声音信号,借助外置16位A/D模块进行信号的ADC采样,通过FFT算法对声音信号进行分析,得到基波电压幅值和四次谐波幅值,计算出音响设备的失真度,进而得到音响设备的频响范围,最终将结果显示在屏幕上。该装置填补了市面上音响品质测试系统的空白,具有较好的测试精度和可靠度,且结构紧凑,显示直观,使用简单,能够满足实际使用需求。 展开更多
关键词 STM32单片机 音响品质测试 FFT算法 失真度 频响范围
在线阅读 下载PDF
集成式GaN单开关管功率因数校正变换器
19
作者 曹通 秦世清 +4 位作者 何映谊 李婷 张秀梅 杨国锋 卞宝安 《重庆大学学报》 CAS CSCD 北大核心 2024年第7期63-73,共11页
传统的降压型功率因数校正(power factor correction,PFC)变换器由于存在高谐波电流的缺点,较难满足IEC61000-3-2 C类限值,其应用受到很大限制。文中设计并搭建了一种集成式功率因数校正变换器,该变换器由一个降压PFC变换器和一个反激PF... 传统的降压型功率因数校正(power factor correction,PFC)变换器由于存在高谐波电流的缺点,较难满足IEC61000-3-2 C类限值,其应用受到很大限制。文中设计并搭建了一种集成式功率因数校正变换器,该变换器由一个降压PFC变换器和一个反激PFC变换器组成,其中降压和反激PFC变换器采用输入并联和输出并联连接方式共用一个GaN开关管和控制电路,降低变换器成本。集成式变换器在临界导通模式(critical conduction mode,CRM)恒定导通时间(constant on time,COT)控制下,反激单元消除了降压输入电流死区的影响,利用降压和反激PFC变换器的优势和GaN开关管的优异性能,变换器可以在宽电压输入范围下实现高效率和低总谐波失真。文中介绍了电路结构和工作原理,通过PSIM(power simulation)仿真验证理论推导的正确性,最后搭建了满载效率为94.1%的120 W样机,验证了该方案的可行性。 展开更多
关键词 功率因数校正变换器 氮化镓 集成式 低总谐波失真
在线阅读 下载PDF
微型扬声器总谐波失真测量的衍射效应
20
作者 曾宪宏 冯雪磊 沈勇 《应用声学》 CSCD 北大核心 2024年第5期941-948,共8页
该文旨在消除衍射效应对微型扬声器总谐波失真测量的影响,根据扩展的Biot–Tolstoy–Medwin模型,研究了微型扬声器总谐波失真测量的衍射效应,重点分析了微型扬声器后腔封闭和后腔开放的两种不同条件下考虑微型扬声器后向衍射和不考虑后... 该文旨在消除衍射效应对微型扬声器总谐波失真测量的影响,根据扩展的Biot–Tolstoy–Medwin模型,研究了微型扬声器总谐波失真测量的衍射效应,重点分析了微型扬声器后腔封闭和后腔开放的两种不同条件下考虑微型扬声器后向衍射和不考虑后向衍射的两种情况。该文使用的是简单稳定的障板测试条件,由于衍射效应与障板尺寸和微型扬声器的安装位置有关,因此该文将微型扬声器安装在固定尺寸的障板上的固定位置。该文理论计算了不同测量距离下障板的衍射曲线,分析了对应情况下微型扬声器总谐波失真测量的衍射效应,并进行实验验证。实验结果与理论计算吻合良好,证明了该文计算方法的准确性。该文研究表明,微型扬声器总谐波失真测量的衍射效应受障板的影响较大,且测试距离越远,影响越大,扬声器后腔开放时的衍射效应比后腔封闭时的衍射效应更为明显。使用根据该文的方法计算出的衍射曲线,可以对微型扬声器测量得到的总谐波失真进行修正,消除障板测试条件下衍射效应的影响。 展开更多
关键词 微型扬声器 衍射 总谐波失真 障板
在线阅读 下载PDF
上一页 1 2 27 下一页 到第
使用帮助 返回顶部