期刊文献+
共找到331篇文章
< 1 2 17 >
每页显示 20 50 100
Development of a Peristaltic Micropump for Bio-Medical Applications Based on Mini LIPCA 被引量:1
1
作者 Thanh Tung Nguyen My Pham Nam Seo Goo 《Journal of Bionic Engineering》 SCIE EI CSCD 2008年第2期135-141,共7页
This paper presents the design, fabrication, and experimental characterization of a peristaltic micropump. The micropump is composed of two layers fabricated from Polydimethylsiloxane (PDMS) material. The first laye... This paper presents the design, fabrication, and experimental characterization of a peristaltic micropump. The micropump is composed of two layers fabricated from Polydimethylsiloxane (PDMS) material. The first layer has a rectangular channel and two valve seals. Three rectangular mini lightweight piezo-composite actuators are integrated in the second layer, and used as actuation parts. Two layers are bonded, and covered by two Polymethyl Methacrylate (PMMA) plates, which help increase the stiffness of the micropump. A maximum flow rate of 900μL.min 1 and a maximum backpressure of 1.8 kPa are recorded when water is used as pump liquid. We measured the power consumption of the micropump. The micropump is found to be a promising candidate for bio-medical application due to its bio-compatibility, portability, bidirectionality, and simple effective design. 展开更多
关键词 peristaltic micropump LIPCA PDMS bio-medical applications
在线阅读 下载PDF
LIQUID-SOLID COUPLED SYSTEM OF MICROPUMP 被引量:1
2
作者 WU Jiankang Lu Lijun 《Acta Mechanica Solida Sinica》 SCIE EI 2006年第1期40-49,共10页
This paper employs the integral-averaged method of thickness to approximate the periodical flows in a piezoelectric micropump, with a shallow water equation including nonlinearity and viscous damp presented to charact... This paper employs the integral-averaged method of thickness to approximate the periodical flows in a piezoelectric micropump, with a shallow water equation including nonlinearity and viscous damp presented to characterize the flows in micropump. The finite element method is used to obtain a matrix equation of fluid pressure. The fluid pressure equation is combined with the vibration equation of a silicon diaphragm to construct a liquid-solid coupled equation for reflecting the interaction between solid diaphragm and fluid motion in a micropump. Numerical results of a mode analysis of the coupled system indicate that the natural frequencies of the coupled system are much lower than those of the non-coupled system. The influence of additional mass and viscous damp of fluid on the natural frequencies of the coupled system is more significant as the pump thickness is small. It is found that the vibration shape functions of silicon diaphragm of the coupled system are almost the same as those of the non-coupled system. This paper also gives the first-order amplitude-frequency relationship of the silicon diaphragm, which is necessary for the flow-rate-frequency analysis of a micropump. 展开更多
关键词 micropump liquid-solid coupled system shallow water equation finite element method
在线阅读 下载PDF
A Novel Integrated PZT-Driven Micropump and Microvalve
3
作者 Zhaoxin Geng Dafu Cui Haining Wang Changchun Liu Bo Su 《稀有金属材料与工程》 SCIE EI CAS CSCD 北大核心 2006年第A03期540-542,共3页
According to the'elastic buffer mechanism'and the'variable gap mechanism',a new device,which is both micropump and active microvalve actuated by PZT bimorph cantilever,was fabricated with polydimethyis... According to the'elastic buffer mechanism'and the'variable gap mechanism',a new device,which is both micropump and active microvalve actuated by PZT bimorph cantilever,was fabricated with polydimethyisiloxane (PDMS) and silicon chip.The thickness of the micropump membrance is about 180μm.The diameter and the depth of micropump chamber cavity are 6 mm and 40μm,respectively.The performances of the micropump,such as pump rate and backpressure,were characterized.As a flow-rectifying element,the diffusers and active valve were used instead of passive check valves.The flow rate and the backpressure of the micropump are about 420μL/min and 2 kPa when applying a 100 V square wave driving voltage at frequency of 35 Hz. 展开更多
关键词 micropump MICROVALVE PZT PDMS
在线阅读 下载PDF
A NEW TYPE OF MICROPUMP DRIVEN BY A LOW ELECTRIC VOLTAGE
4
作者 郭书祥 ASAKA Kinji 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 2004年第2期146-151,共6页
In this paper,we propose a new prototype model of a micro pump using ICPF(Ionic Conducting Polymer Film)actuator as the servo actuator.This micro pump consists of two active one- way valves that make use of the same I... In this paper,we propose a new prototype model of a micro pump using ICPF(Ionic Conducting Polymer Film)actuator as the servo actuator.This micro pump consists of two active one- way valves that make use of the same ICPF actuator.The overall size of this micro pump prototype is 12mm in diameter and 20mm in length.The actuating mechanism is as follows:(1)The ICPF actuator as the diaphragm is bent into anode side by application of electricity.Then the volume of the pump chamber increases,resulting in the inflow of liquid from the inlet to the chamber.(2)By changing the current direction,the volume of the pump chamber decreases,resulting in the liquid flow from the chamber to the outlet.(3)The ICPF actuator is put on a sine voltage,the micro pump provides liquid flow from the inlet to the outlet continuously.Characteristic of the micro pump is measured.The experimental results indicate that the micro pump has the satisfactory responses. 展开更多
关键词 micro machine micropump ionic conducting polymer film(ICPF)actuator medical applications BIOTECHNOLOGY
在线阅读 下载PDF
Manipulating fluid with vibrating 3D-printed paddles for applications in micropump
5
作者 Zhiyong Tang Xiufeng Shao +2 位作者 Jianze Huang Jinyuan Yao Guifu Ding 《Nanotechnology and Precision Engineering》 EI CAS CSCD 2019年第3期95-104,共10页
This paper presents a novel working mechanism of a micropump using micropaddles(MPs)to actively manipulate fluid based on 3 D printing technology.The novel working principle is systematically discussed using analysis,... This paper presents a novel working mechanism of a micropump using micropaddles(MPs)to actively manipulate fluid based on 3 D printing technology.The novel working principle is systematically discussed using analysis,computation and experiment methods.A theoretical model is established to research the working mechanism and crucial parameters for driving ability,such as MPs shape,size,vibration amplitude and frequency.Two different 3 D printing techniques that simplify the multi-step process into only one step are introduced to manufacture the prototype pump for investigating the principle experimentally.A testing system is designed to evaluate the flow rate of pumps with eight different vibrating paddles.A maximum flux of 127.9 mL/min is obtained at an applied voltage of 9 V.These experiments show that the active-type mechanical pump could not only freely control flow direction but also change flux by adopting different shapes or distribution ways.The advantage of the novel micropump is the application of the MP structure into the micropump system to actively manipulate fluid with flexibility and high driving ability at fairly low power. 展开更多
关键词 micropump Manipulate fluid Vibrating micropaddles 3D printing Fluid-structure interaction
在线阅读 下载PDF
Analysis of Vibrational Performance of A Piezoelectric Micropump with Diffuse/Nozzle Microchannel
6
作者 Yanfang Guan Xiang Li 《Nanotechnology and Precision Engineering》 EI CAS CSCD 2018年第2期138-144,共7页
Piezoelectric transducers of different external diameters are designed and fabricated and incorporated into micropumps. Through finite element analysis, it is shown that the volume efficiency of the micropump reaches ... Piezoelectric transducers of different external diameters are designed and fabricated and incorporated into micropumps. Through finite element analysis, it is shown that the volume efficiency of the micropump reaches its maximum value for the first mode of vibration. The variation of maximum displacement with frequency is determined under free and forced vibration. Results demonstrate that this variation shows the same trend for different driving waves at the same driving voltage. The maximum displacement under forced vibration is less than that under free vibration. The displacement increases with decreasing distance from the center of the transducer. The maximum displacement is inversely proportional to the diameter of the transducer and proportional to the driving voltage under both free and forced vibrations. Finally, the micropump flow rate and pressure are measured and are found to manifest the same trend as the maximum displacement under the same driving conditions. For a piezoelectric transducer of 12 mm external diameter, the maximum flow rate and pressure value are 150 μL/min and 346 Pa, respectively, under sine-wave driving at 100 Vpp driving voltage. 展开更多
关键词 micropump Vibrational displacement Piezoelectric transducer MICROFLOW
在线阅读 下载PDF
The dynamic characteristics of a valve-less micropump
7
作者 蒋丹 李松晶 《Chinese Physics B》 SCIE EI CAS CSCD 2012年第7期359-367,共9页
The aim of this paper is to investigate the dynamic characteristics of a valve-less micropump. A dynamic mathe- matical model of the micropump based on a hydraulic analogue system and a simulation method using AMESim ... The aim of this paper is to investigate the dynamic characteristics of a valve-less micropump. A dynamic mathe- matical model of the micropump based on a hydraulic analogue system and a simulation method using AMESim software are developed. By using the finite-element analysis method, the static analysis of the diaphragm is carried out to ob- tain the maximum deflection and volumetric displacement. Dynamic characteristics of the valve-less micropump under different excitation voltages and frequencies are simulated and tested. Because of the discrepancy between simulation results and experimental data at frequencies other than the natural frequency, the revised model for the diaphragm maximum volumetric displacement is presented. Comparison between the simulation results based on the revised model and experimental data shows that the dynamic mathematical model based on the hydraulic analogue system is capable of predicting dynamic characteristics of the valve-less micropump at any excitation voltage and frequency. 展开更多
关键词 valve-less micropump dynamic characteristics hydraulic analogue model DIFFUSER
在线阅读 下载PDF
A Hybrid Silicon-PDMS Micropump Actuated by PZT Bimorph
8
作者 Haining Wang Dafu Cui Zhaoxin Geng Xing Chen 《稀有金属材料与工程》 SCIE EI CAS CSCD 北大核心 2006年第A03期319-320,共2页
The fabrication and characterization of a hybrid Silicon-PDMS micropump based on MEMS technology is presented. The micropump consists of one chamber,two passive valves and one PDMS diaphragm.A PZT bimorph working as t... The fabrication and characterization of a hybrid Silicon-PDMS micropump based on MEMS technology is presented. The micropump consists of one chamber,two passive valves and one PDMS diaphragm.A PZT bimorph working as the actuator is mounted on the PDMS diaphragm.The use of the PDMS diaphragm and the PZT bimorph can give rise to large displacements of the pump diaphragm,making the micropump more efficient and easier to be fabricated.The flow rate of the micropump is a function to the voltage and frequency of the applied square wave.When a square wave of 100V is applied,a maximum flow rate of 317μL/min and a back-pressure of 2 kPa are achieved at 20 Hz. 展开更多
关键词 micropump PZT bimorph PDMS
在线阅读 下载PDF
Design and fabrication process of electromagnetically actuated valveless micropump with two parallel flexible diaphragms
9
作者 苏宇锋 陈文元 +1 位作者 崔峰 张卫平 《Journal of Shanghai University(English Edition)》 CAS 2007年第1期79-83,共5页
A parallel dynamic passive valveless micropump was designed, which consists of three layers-valve, diaphragm and electromagnetic coil. The valve was wetly etched in a silicon wafer, the diaphragm was a PDMS (polydime... A parallel dynamic passive valveless micropump was designed, which consists of three layers-valve, diaphragm and electromagnetic coil. The valve was wetly etched in a silicon wafer, the diaphragm was a PDMS (polydimethyl siloxane) film spun on a silicon wafer with embedded permanent magnet posts, and the coil was electroplated on a silicon substrate. Under the actuation of the magnetic field generated by coils, the flexible diaphragm could be displaced upwards and downwards. After analyzing magnetic and mechanical characteristic of the flexible membrane and direction-dependence of the nozzle, a micropump was designed. And the relative length (L/d) of the micropump nozzle was taken 4. A 7 × 7 array of permanent magnetic posts was embedded in the PDMS film. Two diaphragms worked in an anti-step mode, which could relieve the liquid shock and increase the discharge of the micropump. The ANSYS and Matlab were adopted to analyze the actuation effect of the coil and the flow characteristic of the micropump. Results show that when actuated under a 0.3 A, 100 Hz current, the displacement of the diaphragm is more than 30 μm, and the discharge of the micropump is about 6 μL/s. 展开更多
关键词 micropump valveless permanent magnet polydimethyl siloxane (PDMS)
在线阅读 下载PDF
Hybrid Optimization of a Valveless Diaphragm Micropump Using the Cut-Cell Method
10
作者 kapsoulis K.Samouchos +1 位作者 X.Trompoukis K.Giannakoglou 《Journal of Mechanics Engineering and Automation》 2019年第4期120-127,共8页
This paper presents the optimization of 3D valveless diaphragm micropump for medical applications.The pump comprises an inlet and outlet diffuser connected to the main chamber equipped with a periodically moving diaph... This paper presents the optimization of 3D valveless diaphragm micropump for medical applications.The pump comprises an inlet and outlet diffuser connected to the main chamber equipped with a periodically moving diaphragm that generates the unsteady flow within the device.The optimization,which is related exclusively to the diaphragm motion,aims at maximizing the net flowrate and minimizing the backflow at the outlet diffuser.All CFD analyses are performed using an in-house cut-cell method,based on the finite volume approach,on a many-processor system.To reduce the optimization turn-around time,two optimization methods,a gradient-free evolutionary algorithm enhanced by surrogate evaluation models and a gradient-based(GB)method are synergistically used.To support the GB optimization,the continuous adjoint method that computes the gradient of the objectives with respect to the design variables has been developed and programmed.Using the hybrid optimization method,the Pareto front of non-dominated solutions,in the two-objective space,is computed.Finally,a couple of optimal solutions selected from the computed Pareto front are re-evaluated by considering uncertainties in the operating conditions;these are quantified using the polynomial chaos expansion method. 展开更多
关键词 DIAPHRAGM micropump cut-cell METHOD hybrid optimization ADJOINT METHOD evolutionary algorithm uncertaintyquantification
在线阅读 下载PDF
Performance of a serial-connection multi-chamber piezoelectric micropump 被引量:3
11
作者 KAN Jun-wu XUAN Ming +2 位作者 LIU Guo-jun YANG Zhi-gang WU Yi-hui 《光学精密工程》 EI CAS CSCD 北大核心 2005年第5期535-541,共7页
The concept and structure of serial-connection multi-chamber (SCMC) micropumps with cantilever valves is introduced. The SCMC micropump, which can be manufactured using conventional production techniques and materials... The concept and structure of serial-connection multi-chamber (SCMC) micropumps with cantilever valves is introduced. The SCMC micropump, which can be manufactured using conventional production techniques and materials, has a multi-layer circular planar structure. The border-upon piezoelectric actuators of a SCMC micropump work in anti-phase, as a result the pumping performance is similar to that of several single-chamber pumps running in series. The theoretical analysis shows that the pumping performance of a SCMC micropump depends not only on the characteristic and geometrical parameters of the piezoelectric actuators, but also on the number of pump chambers. Both flowrate and pressure of a SCMC pump can be enhanced to a certain extent. Four piezoelectric micropumps with different chambers were fabricated and tested. The testing results show that the enhancing extents of the flowrate and pressure of a SCMC piezoelectric micropump are different. The maximum flowrate and pressure of the four-chamber pump achieved are 2.5 times and 3.6 times those of the single-chamber pump achieved. 展开更多
关键词 SCMC 微电子系统 MEMS PZT 压电泵
在线阅读 下载PDF
Simulation of the fluidic features for diffuser/nozzle involved in a PZT-based valveless micropump 被引量:2
12
作者 HouWensheng Zheng Xiaolin +4 位作者 Biswajit Das Jiang Yingtao Qian Shizhi Wu Xiaoying Zheng Zhigao 《仪器仪表学报》 EI CAS CSCD 北大核心 2008年第1期1-4,共4页
PZT-based valveless micropump is a microactuator that can be used for controlling and delivering tiny amounts of fluids,and diffuser/nozzle plays an important role when this type of micropump drives the fluid flowing ... PZT-based valveless micropump is a microactuator that can be used for controlling and delivering tiny amounts of fluids,and diffuser/nozzle plays an important role when this type of micropump drives the fluid flowing along a specific direction.In this paper,a numerical model of micropump has been proposed,and the fluidic properties of diffuser/nozzle have been simulated with ANSYS.With the method of finite-element analysis,the increased pressure drop between inlet and outlet of diffuser/nozzle induces the increment of flow rate in both diffuser and nozzle simultaneously,but the increasing rate of diffuser is faster than that of nozzle.The L/R,ratio of L(length of cone pipe) and R(radius of minimal cross section of cone pipe) plays an important role in fluidic performance of diffuser and nozzle as well,and the mean flow rate will decrease with increment of L/R.The mean flow rate reaches its peak value when L/R with the value of 10 regardless the divergence angle of diffuser or nozzle.The simulation results indicate that the fluidic properties of diffuser/nozzle can be defined by its geometric structure,and accordingly determine the efficiency of micropump. 展开更多
关键词 流体系统 模拟 无阀微型泵 散流器 喷嘴
在线阅读 下载PDF
血管紧张素Ⅱ微量泵植入和皮下注射致小鼠心肌纤维化的造模方法比较
13
作者 潘亮亮 张思涵 +5 位作者 王雪晴 杨晓薇 王少兰 李汨 马晓真 于远望 《陕西医学杂志》 CAS 2025年第1期14-20,共7页
目的:比较血管紧张素Ⅱ(AngⅡ)微量泵植入和皮下注射两种造模方式及不同剂量致小鼠心肌纤维化的成模情况及成模差异性,确定较优的动物模型复制方法。方法:40只雄性C57BL/6小鼠随机分为空白对照组、微量泵组[微量泵皮下植入1.5 mg/(kg... 目的:比较血管紧张素Ⅱ(AngⅡ)微量泵植入和皮下注射两种造模方式及不同剂量致小鼠心肌纤维化的成模情况及成模差异性,确定较优的动物模型复制方法。方法:40只雄性C57BL/6小鼠随机分为空白对照组、微量泵组[微量泵皮下植入1.5 mg/(kg·d)]、皮下组1[皮下注射1.5 mg/(kg·d)]和皮下组2[皮下注射2.5 mg/(kg·d)],每组10只,空白组不做任何处理,其余组给予AngⅡ,持续28 d,观察小鼠一般状态。第28天行心电图和超声心动图检测心功能,HE、Masson染色观察心脏病理变化,ELISA检测血清脑钠肽(BNP)水平,Western blot检测心肌α-平滑肌肌动蛋白(α-SMA)、Ⅰ型胶原蛋白(CollagenⅠ)、Ⅲ型胶原蛋白(CollagenⅢ)蛋白表达。结果:同空白对照组比较,各给药组小鼠一般状态、心电图受影响程度为微量泵组>皮下组2>皮下组1。超声心动图微量泵组和皮下组2的左室射血分数(EF)、左室短轴缩短率(FS)下降(均P<0.05),左室舒张末期内径(LVIDd)、左室收缩末期内径(LVIDs)、左室舒张末期容量(LVEDV)、左室收缩末期容量(LVESV)、左室质量(LVd Mass)均上升(均P<0.05);皮下组1的FS下降(P<0.05),LVIDs、LVIDd上升(均P<0.05),各组间EF比较有统计学差异(均P<0.05)。微量泵组和皮下组2的BNP均显著升高(P<0.05),皮下组1与空白对照组比较无统计学差异,各给药组间比较差异有统计学意义(P<0.05)。HE染色微量泵组炎性细胞浸润明显大于皮下组,Masson染色胶原纤维沉积高于皮下组2(均P<0.05),皮下组1与空白对照组比较无统计学差异(P>0.05)。Western blot微量泵组和皮下组2的α-SMA、CollagenⅠ、CollagenⅢ蛋白表达显著增高(均P<0.05),皮下组1仅α-SMA增高(P<0.05)。结论:微量泵1.5 mg/(kg·d)和皮下注射2.5 mg/(kg·d)累积28 d均可建立心肌纤维化模型,微量泵组明显优于皮下注射;皮下注射1.5 mg/(kg·d)诱导心肌纤维化不明显。 展开更多
关键词 血管紧张素Ⅱ 心肌纤维化 造模方法 微量泵植入 皮下注射 动物模型
在线阅读 下载PDF
Design,fabrication and experimental research for an electrohydrodynamic micropump 被引量:6
14
作者 YU He, YU Jian & MA ChongFang Key Lab of Enhanced Heat Transfer & Energy Conservation, Ministry of Education and Key Lab of Heat Transfer & Energy Conversion, Beijing Municipality, College of Enviromental and Energy Engineering, Beijing University of Technology, Beijing 100124, China 《Science China(Technological Sciences)》 SCIE EI CAS 2010年第10期2839-2845,共7页
This paper presented a novel electrohydrodynamic (EHD) micropump based on MEMS technology. The working mechanisms and classification of EHD micropump were introduced. The fabrication process of EHD micropump was prese... This paper presented a novel electrohydrodynamic (EHD) micropump based on MEMS technology. The working mechanisms and classification of EHD micropump were introduced. The fabrication process of EHD micropump was presented with the material selection,optimal design of microelectrode and assembly process. Static pressure experiments and flow experiments were carried out using different fluid and the channel depth. The results indicated that the micropump could achieve a maximum static pressure head of 268 Pa at an applied voltage of 90 V. The maximum flow rate of the micropump-driven fluid could reach 106 μL/min. This paper analyzed the future of combining micropump with heat pipe to deal with heat dissipation of high power electronic chips. The maximum heat dissipation capacity of 87 W/cm2 can be realized by vaporizing the micropump-driven liquid on vaporizing section of the heat pipe. 展开更多
关键词 ELECTROHYDRODYNAMIC (EHD) MEMS micropump ELECTRONIC COOLING
原文传递
Experimental investigation on phase transformation type micropump 被引量:1
15
作者 Li, ZX Wang, MR Tan, LY 《Chinese Science Bulletin》 SCIE EI CAS 2002年第6期518-522,共5页
The phase transformation type micropump without moving parts was experimentally studied in this note. To analyze the pumping mechanism of the micropump, a simplified physical model was presented. The experimental resu... The phase transformation type micropump without moving parts was experimentally studied in this note. To analyze the pumping mechanism of the micropump, a simplified physical model was presented. The experimental results indicate that the pump characteristic is mainly dependent on the heating and cooling conditions. For a given system, there exist an optimal combination of heating current and switch time with which the flow rate reaches maximum. Comparing with the natural cooling, the forced con-vective cooling needs larger heating current to obtain the same flow rate. In our experiments, the maximum flow rate is 33μL/min when the inner diameter of the micropump is 200μm, and the maximum pumping pressure reaches over 20 kPa. The theoretical analysis shows that the pumping mechanism of the micropump mainly lies in the large density difference between liquid and gas phases and the effect of gas chocking. 展开更多
关键词 micropump PHASE TRANSFORMATION PUMPING character-istic.
原文传递
A novel hydrodynamic suspension micropump using centrifugal pressurization and the wedge effect 被引量:2
16
作者 XING GuanYing XUE Song +2 位作者 HONG Tao ZUO HuaiYu LUO XiaoBing 《Science China(Technological Sciences)》 SCIE EI CAS CSCD 2023年第7期2047-2058,共12页
The micropump is the heart of microfluidics systems.However,for mechanical micropumps,bearing wear failure has been a major obstacle to performance and reliability.Hydrodynamic suspension,which can make the rotating c... The micropump is the heart of microfluidics systems.However,for mechanical micropumps,bearing wear failure has been a major obstacle to performance and reliability.Hydrodynamic suspension,which can make the rotating components levitate in liquid without any mechanical friction,is applied to break this bottleneck.In this paper,a novel kind of hydrodynamic suspension micropump(HSMP) without a grooved thrust bearing is proposed.Based on the centrifugal effect,the HSMP uses a rotating rotor to accelerate and pressurize adjacent fluid,and thus reacting forces are generated on the rotor surfaces to levitate it.The mechanisms of suspension forces formation,the centrifugal effect and the wedge effect in the liquid films near the rotor are identified using theoretical analysis and simulation.The variation in suspension forces with rotor position is investigated,revealing that the suspension bearings of the HSMP,similar to a spring damper,can self-adjust suspension forces along with a change in rotor position.Moreover,the suspension stiffness is positively correlated with the rotating speed.The HSMP prototype designed herein,whose overall size is only 34 mm × 34 mm × 31 mm,can provide a maximum output performance of3230 mL/min and 96.3 kPa at 20000 r/min,which is manyfold greater than other micropumps.The proposed HSMP is demonstrated to be more powerful with a simple structure,high power density,and high reliability. 展开更多
关键词 hydrodynamic levitation SUSPENSION micropump
原文传递
Light-powered direction-controlled micropump
17
作者 Mingtong Li Yajun Su +1 位作者 Hui Zhang Bin Dong 《Nano Research》 SCIE EI CAS CSCD 2018年第4期1810-1821,共12页
A micropump induces the flow of its surrounding fluids and is extremely promising in a variety of applications such as chemical sensing or mass transportation. However, it is still challenging to manipulate its pumpin... A micropump induces the flow of its surrounding fluids and is extremely promising in a variety of applications such as chemical sensing or mass transportation. However, it is still challenging to manipulate its pumping direction. In this stud~ we examine a binary micropump based on perovskite and poly[(2-methoxy-5-ethylhexyloxy)-1,4-phenylenevinylene] (MEHPPV). The micropump is operational under the influence of light. Light exhibits significant versatility in controlling the pumping phenomenon of the micropump. It governs the start and stop and also regulates the velocity and directions. The direction control signifies immense opportunities for the development of micropumps with unprecedented pumping behaviors and functions (such as heartbeat-like pumping, rectification, and amplification). This makes them potentially useful in various fields. Hence, it is expected that the micropump reported in the current study could act as a key step towards the further development of more sophisticated micropumps for diverse applications. 展开更多
关键词 micropump light powered density-driven thermal effect direction control
原文传递
Valveless Thermally-Driven Phase-Change Micropump
18
作者 王沫然 李志信 《Tsinghua Science and Technology》 SCIE EI CAS 2004年第6期688-693,共6页
A dynamic model with moving heat sources was developed to analyze the pumping mechanism of a valveless thermally-driven phase-change micropump. The coupled equations were solved to determine the pumping characteristic... A dynamic model with moving heat sources was developed to analyze the pumping mechanism of a valveless thermally-driven phase-change micropump. The coupled equations were solved to determine the pumping characteristics. The numerical results agree with experimental data from micropumps with different diameter microtubes. The maximum flow rate reached 33 μL / min and the maximum pump pressure was over 20 kPa for a 200-μm diameter microtube. Analysis of the pumping mechanism shows that the main factors affecting the flow come from the large density difference between the liquid and vapor phases and the choking effect of the vapor region. 展开更多
关键词 valveless micropump phase change pumping mechanism
原文传递
Fluidic Control System Employing Micropump and Microvalves for Cell Isolation
19
作者 张坚 荆高山 +2 位作者 许俊泉 程京 周玉祥 《Tsinghua Science and Technology》 SCIE EI CAS 2001年第3期277-280,284,共5页
A micro fluidic system was developed and used for cell isolation on biochips. The flow speed could be precisely adjusted by a micropump, and the flow direction could be controlled by switching valves. The complete ope... A micro fluidic system was developed and used for cell isolation on biochips. The flow speed could be precisely adjusted by a micropump, and the flow direction could be controlled by switching valves. The complete operation was computer controlled. The control system for the micropump and microvalves is discussed here. This control system can be combined with other biochip devices to construct a micro total analysis system (μTAS). 展开更多
关键词 MICROFLUIDICS micropump MICROVALVE micro total analysis system (μTAS)
原文传递
Viscous Micropump Simulation by Particle/Continuum Methods
20
作者 王盛 罗昔联 +2 位作者 雷康斌 顾兆林 KASE Kiwamu 《Journal of Shanghai Jiaotong university(Science)》 EI 2011年第3期364-367,共4页
A novel viscous micropump consisting of a cylindrical rotor eccentrically placed inside a microchannel is simulated by the two Volume-CAD(V-CAD)framework-based flow solvers,i.e.,the direct simulation Monte Carlo(DSMC)... A novel viscous micropump consisting of a cylindrical rotor eccentrically placed inside a microchannel is simulated by the two Volume-CAD(V-CAD)framework-based flow solvers,i.e.,the direct simulation Monte Carlo(DSMC)package(named as V-DSMC)and the Navier-Stoke solver(named as V-Flow).V-DSMC is used in the case of the pump applied to gas,while V-Flow is applied to model the pump in the case of liquid working medium.The pumping performance curves under different liquid media with the variation of Reynolds number,as well as under different eccentricity factors are obtained.The performance and the flow filed characteristics are very sensitive to the tangential momentum accommodation coefficient in the case of gas medium.Three recirculations exist in the flow field,and the sizes of recirculation are different at the different operating points in a performance curve. 展开更多
关键词 viscous micropump pumping performance flow field characteristics
原文传递