BACKGROUND In recent years,confocal laser endomicroscopy(CLE)has become a new endoscopic imaging technology at the microscopic level,which is extensively performed for real-time in vivo histological examination.CLE ca...BACKGROUND In recent years,confocal laser endomicroscopy(CLE)has become a new endoscopic imaging technology at the microscopic level,which is extensively performed for real-time in vivo histological examination.CLE can be performed to distinguish benign from malignant lesions.In this study,we diagnosed using CLE an asymptomatic patient with poorly differentiated gastric adenocarcinoma.CASE SUMMARY A 63-year-old woman was diagnosed with gastric mucosal lesions,which may be gastric cancer,in the small curvature of the stomach by gastroscopy.She consented to undergo CLE for morphological observation of the gastric mucosa.Through the combination of CLE diagnosis and postoperative pathology,the intraoperative CLE diagnosis was considered to be reliable.According to our experience,CLE can be performed as the first choice for the diagnosis of gastric cancer.CONCLUSION CLE has several advantages over pathological diagnosis.We believe that CLE has great potential in the diagnosis of benign and malignant gastric lesions.展开更多
AIM:To evaluate the effects of antiglaucoma eye drops on corneal nerves by in vivo confocal microscopy(IVCM).METHODS:This study comprised 79 patients diagnosed with glaucoma and 16 healthy control individuals.Among th...AIM:To evaluate the effects of antiglaucoma eye drops on corneal nerves by in vivo confocal microscopy(IVCM).METHODS:This study comprised 79 patients diagnosed with glaucoma and 16 healthy control individuals.Among the glaucoma patients,54 were treated with medication,while 25 remained untreated.Central corneal images were evaluated by IVCM,and then ACCMetrics was used to calculate the following parameters:corneal nerve fiber density(CNFD),branch density(CNBD),fiber length(CNFL),total branch density(CTBD),fiber area(CNFA),fiber width(CNFW),and fractal dimension(CNFrD).The correlation between IVCM parameters and drugs was evaluated using non-parametric measurements of Spearman’s rank correlation coefficient.RESULTS:The CNFD was reduced in glaucoma groups compared to healthy subjects(P<0.01).Patients using anti-glaucoma medications exhibited poorer confocal parameters compared to untreated patients.As the number of medications and usage count increased,CNFD,CNBD,CNFL,CTBD,CNFA,and CNFrD experienced a decline,while CNFW increased(all P<0.01).For the brinzolamide-therapy group,there was a significant decrease in CNFD and CNFL compared to the other monotherapy groups(P<0.001).In the absence of medication,CNFD in males was lower than that in females(P<0.05).Among patients under medication therapy,CNFD remained consistent between males and females.CONCLUSION:Antiglaucoma eye drops affect the microstructure of corneal nerves.IVCM and ACCMetrics are useful tools that could be used to evaluate the corneal nerve changes.展开更多
Gastric cancer(GC)is a multifactorial disease,where both environmental and genetic features can have an impact on its occurrence and development.GC represents one of the leading causes of cancer-related deaths worldwi...Gastric cancer(GC)is a multifactorial disease,where both environmental and genetic features can have an impact on its occurrence and development.GC represents one of the leading causes of cancer-related deaths worldwide.GC is most frequent in males and is believed to arise from a series of premalignant lesions.The detection of GC at an early stage is crucial because early GC,which is an invasive stomach cancer confined to the mucosal or submucosal lining,may be curable with a reported 5-year survival rate of more than 90%.Advanced GC usually has a poor prognosis despite current treatment standards.The diagnostic efficacy of conventional endoscopy(with light endoscopy)is currently limited.Confocal laser endomicroscopy is a novel imaging technique that allows real-time in vivo histological examination of mucosal surfaces during endoscopy.Confocal laser endomicroscopy may be of great importance in the surveillance of precancerous gastric lesions and in the diagnosis of GC.In this editorial we commented on the article about this topic published by Lou et al in the recent issue of the World Journal of Clinical Cases.展开更多
Confocal laser endomicroscopy(CLE)is a novel endoscopic modality that provides real-time histological information via high-resolution magnified view of the mucosa.CLE has a higher sensitivity,specificity,and diagnosti...Confocal laser endomicroscopy(CLE)is a novel endoscopic modality that provides real-time histological information via high-resolution magnified view of the mucosa.CLE has a higher sensitivity,specificity,and diagnostic accuracy in detecting atrophic gastritis as compared to chromoendoscopy and narrow-band imaging.It can even predict low-grade and high-grade intraepithelial neoplasia by analyzing gastric pit patterns.CLE may have some advantages over the standard biopsy protocol,such as higher diagnostic yield and fewer biopsy requirements.Its diagnostic accuracy in detecting superficial gastric cancer is higher than that of white-light endoscopy.Inherent limitations,such as a narrow field of vision,can be surpassed by technological advancements and integration with other detection methods.Artificial intelligence holds promise in automated analysis of histopathological images.Thus,CLE can be helpful in screening for early gastric cancer and may help reduce the risk of complications from repeated biopsies,such as mucosal damage,bleeding,and infection.展开更多
We present a unified electromagnetic modeling of coherence scanning interferometry,confocal microscopy,and focus variation microscopy as the most common techniques for surface topography inspection with micro-and nano...We present a unified electromagnetic modeling of coherence scanning interferometry,confocal microscopy,and focus variation microscopy as the most common techniques for surface topography inspection with micro-and nanometer resolution.The model aims at analyzing the instrument response and predicting systematic deviations.Since the main focus lies on the modeling of the microscopes,the light–surface interaction is considered,based on the Kirchhoff approximation extended to vectorial imaging theory.However,it can be replaced by rigorous methods without changing the microscope model.We demonstrate that all of the measuring instruments mentioned above can be modeled using the same theory with some adaption to the respective instrument.For validation,simulated results are confirmed by comparison with measurement results.展开更多
The solidification process of a conventional superalloy, IN718, was investigated by confocal scanning laser microscope (CSLM). The liquid fraction during solidification was obtained as a function of real time and te...The solidification process of a conventional superalloy, IN718, was investigated by confocal scanning laser microscope (CSLM). The liquid fraction during solidification was obtained as a function of real time and temperature in reference with the in-situ observation. The characteristics of L→γ transformation were analyzed and the γ growing rate of each stage was also calculated. Scheil equation was employed to predict the segregation behavior, and the predict results are in consistence with the experimental results. As a result, the confocal scanning laser microscope shows a great potential for solidification process research.展开更多
The interphase nuclei of parenchyma cells and epidermal cells of garlic ( Allium sativum L.) clove were labelled with rabbit anti_actin antibody and FITC_conjugated goat anti_rabbit IgG antibody. The authors observ...The interphase nuclei of parenchyma cells and epidermal cells of garlic ( Allium sativum L.) clove were labelled with rabbit anti_actin antibody and FITC_conjugated goat anti_rabbit IgG antibody. The authors observed results with fluorescence microscopy and confocal laser scanning microscopy. The nuclei showed prominent green_yellow fluorescence, indicating the presence of actin in the nuclei. Fluorescence examination with TRITC_phalloidin showed distinctive red fluorescence in the nuclei, indicating that F_actin is present in the nuclei. Confocal laser scanning microscopy indicated the presence of F_actin containing network structures in the nuclei, but the network structures were absent and the nuclei still showed red fluorescence when the cells were treated with cytochalasin D before fixation; the red fluorescence in the nuclei was hard to be observed when the cells were treated with unlabelled phalloidin before the cells were stained with TRITC_phalloidin. These results indicate that F_actin is in the nuclei and forms network structures in the nuclei of garlic cells.展开更多
A whole-field 3D surface measurement system for semiconductor wafer inspection is described.The system consists of an optical fiber plate,which can split the light beam into N^2 subbeams to realize the whole-field ins...A whole-field 3D surface measurement system for semiconductor wafer inspection is described.The system consists of an optical fiber plate,which can split the light beam into N^2 subbeams to realize the whole-field inspection.A special prism is used to separate the illumination light and signal light.This setup is characterized by high precision,high speed and simple structure.展开更多
AIM: To classify the histological severity of Helicobacter pylori (H. pylori) infection-associated gastritis by confocal laser endomicroscopy (CLE). METHODS: Patients with upper gastrointestinal symptoms or individual...AIM: To classify the histological severity of Helicobacter pylori (H. pylori) infection-associated gastritis by confocal laser endomicroscopy (CLE). METHODS: Patients with upper gastrointestinal symptoms or individuals who were screened for gastric cancer were enrolled in this study. Histological severity of H. pylori infection-associated gastritis was graded according to the established CLE criteria. Diagnostic value of CLE for histo-logical gastritis was investigated and compared with that of white light endoscopy (WLE). Targeted biopsies from the sites observed by CLE were performed. RESULTS: A total of 118 consecutive patients with H. pylori infection-associated gastritis were enrolled in this study. Receiver operating characteristic curve analysis showedthat the sensitivity and specifi city of CLE were 82.9% and 90.9% for the diagnosis of H. pylori infection, 94.6% and 97.4% for predicting gastric normal mucosa, 98.5% and 94.6% for predicting histological active inflammation, 92.9% and 95.2% for predicting glan-dular atrophy, 98.6% and 100% for diagnosing intes-tinal metaplasia, respectively. Post-CLE image analysis showed that goblet cells and absorptive cells were the two most common parameters on the CLE-diagnosed intestinal metaplasia (IM) images (P < 0.001). More his-tological lesions of the stomach could be found by CLE than by WLE (P < 0.001). CONCLUSION: CLE can accurately show the histological severity of H. pylori infection-associated gastritis. Mapping IM by CLE has a rather good diagnostic accuracy.展开更多
In Japan and countries such as South Korea and Tai-wan, China, the standard technique for detecting earlygastric cancer (EGC) is chromoendoscopy. This technique involves a magnified endoscope and the use ofan indigo-c...In Japan and countries such as South Korea and Tai-wan, China, the standard technique for detecting earlygastric cancer (EGC) is chromoendoscopy. This technique involves a magnified endoscope and the use ofan indigo-carmine spray to distinguish between EGCand non-EGC areas. However, this technique is notwidely adopted in many parts of the world. One important reason for limited use is that this technique needsan experienced endoscopist to interpret the imagesduring the procedure. In addition, the sensitivity for detecting gastric intestinal metaplasia (GIM), a precancerous lesion of EGC, is graded as suboptimal. Moreover,the requirement of a cumbersome spraying method isinconvenient and needs preparation time. Easier digitalchromoendoscopy techniques, such as Narrow-bandImaging and Flexible spectral Imaging Color Enhancement, have been reported to facilitate targeted GIM and EGC biopsy. They provide higher sensitivities over conventional white light endoscopy. Recently, the noveltechnology of confocal laser endomicroscopy has been introduced as a high-magnification (1000 ×) real-time evaluation for many early gastrointestinal (GI) cancersand precancerous GI lesions, including colonic polyp,Barrett's esophagus, and GIM. The advantage of this technique is that it can be used as an in vivo confirmation of the presence of GIM and EGC during endoscopic surveillance. This review aims to explain the current information on the usefulness of digital chromoendos-copy and confocal laser endomicroscopy for evaluating GIM and EGC during endoscopic surveillance and the possible future role of these techniques for GI cancerscreening programs.展开更多
AIM:To evaluate the diagnosis of different differentiated gastric intraepithelial neoplasia (IN) by magnifica-tion endoscopy combined with narrow-band imaging (ME-NBI) and confocal laser endomicroscopy (CLE). METHODS:...AIM:To evaluate the diagnosis of different differentiated gastric intraepithelial neoplasia (IN) by magnifica-tion endoscopy combined with narrow-band imaging (ME-NBI) and confocal laser endomicroscopy (CLE). METHODS:Eligible patients with suspected gastric IN lesions previously diagnosed by endoscopy in secondary hospitals and scheduled for further diagnosis and tratment were recruited for this study. Excluded from the study were patients who had liver cirrhosis, impaired renal function, acute gastrointestinal (GI) bleeding, coagulopathy, esophageal varices, jaundice, and GI post-surgery. Also excluded were those who were pregnant, breastfeeding, were younger than 18 years old, or were unable to provide informed consent. All patients had all mucus and bile cleared from their stom-achs. They then received upper GI endoscopy. When a mucosal lesion is found during observation with whitelight imaging, the lesion is visualized using maximal magnification, employing gradual movement of the tip of the endoscope to bring the image into focus. Saved images are analyzed. Confocal images were evaluated by two endoscopists (Huang J and Li MY), who were familiar with CLE, blinded to the related information about the lesions, and asked to classify each lesion as either a low grade dysplasia (LGD) or high grade dysplasia (HGD) according to given criteria. The results were compared with the final histopathologic diagnosis. ME-NBI images were evaluated by two endoscopists (Lu ZS and Ling-Hu EQ) who were familiar with NBI, blinded to the related information about the lesions and CLE images, and were asked to classify each lesion as a LGD or HGD according to the "microvascular pattern and surface pattern" classification system. The results were compared with the final histopathologic diagnosis. RESULTS: The study included 32 pathology-proven low grade gastric IN and 26 pathology-proven high grade gastric IN that were detected with any of the modalities. CLE and ME-NBI enabled clear visualization of the vascular microsurface patterns and microvascular structures of the gastric mucosa. The accuracy of the CLE and the ME-NBI diagnosis was 88% (95% CI:78%-98%) and 81% (95% CI: 69%-93%), respectively. The kappa coefficient of agreement between the histopathology and the in vivo CLE imaging was 0.755; between the histopathology and the in vivo CLE imaging was 0.615. McNemar's test (binomial distribution used) indicated that the agreement was significant (P < 0.05). When patients were diagnosed by MENBI with CLE, the overall accuracy of the diagnosis was 86.21% (95% CI:73%-96%), and the kappa coefficient of agreement was 0.713, according to McNemar's test (P < 0.05). CONCLUSION:Higher diagnostic accuracy, sensitivityand specificity of CLE over ME-NBI indicate the feasibility of these two techniques for the efficacious diagnostic classification of gastric IN.展开更多
Recent technological advances in miniaturization have allowed for a confocal scanning microscope to be integrated into a conventional flexible endoscope,or into trans-endoscopic probes,a technique now known as confoca...Recent technological advances in miniaturization have allowed for a confocal scanning microscope to be integrated into a conventional flexible endoscope,or into trans-endoscopic probes,a technique now known as confocal endomicroscopy or confocal laser endomicroscopy.This newly-developed technology has enabled endoscopists to collect real-time in vivo histological images or "virtual biopsies" of the gastrointestinal mucosa during endoscopy,and has stimulated significant interest in the application of this technique in clinical gastroenterology.This review aims to evaluate the current data on the technical aspects and the utility of this new technology in clinical gastroenterology and its potential impact in the future,particularly in the screening or surveillance of gastrointestinal neoplasia.展开更多
AIM To investigate the application of confocallaser scanning microscopy(CLSM)in tumorpathology and three-dimensional( 3-D )reconstruction by CLSM in pathologic specimensof hepatocellular carcinoma(HCC).METHODS The 30...AIM To investigate the application of confocallaser scanning microscopy(CLSM)in tumorpathology and three-dimensional( 3-D )reconstruction by CLSM in pathologic specimensof hepatocellular carcinoma(HCC).METHODS The 30μm thick sections were cutfrom the paraffin-embedded tissues of HCC,hyperplasia and normal liver,stained with DNAfluorescent probe YOYO-1 iodide and examinedby CLSM to collect optical sections of nuclei and3-D images reconstructed.RESULTS HCC displayed chaotic arrangementof carcinoma cell nuclei,marked pleomorphism,indented and irregular nuclear surface,andirregular and coarse chromatin texture.CONCLUSION The serial optical tomograms ofCLSM can be used to create 3-D reconstruction ofcancer cell nuclei.Such 3-D impressions mightbe helpful or even essential in making anaccurate diagnosis.展开更多
AIM:To review applications of confocal laser endomicroscopy(CLE) in pancreatobiliary lesions and studies that assessed training and interpretation of images. METHODS: A computerized literature search was performed usi...AIM:To review applications of confocal laser endomicroscopy(CLE) in pancreatobiliary lesions and studies that assessed training and interpretation of images. METHODS: A computerized literature search was performed using OVID MEDLINE, EMBASE, Cochrane library, and the ISI Web of Knowledge from 1980 to October 2014. We also searched abstracts from major meetings that included the Digestive Disease Week, Canadian Digestive Disease Week and the United European Gastroenterology Week using a combination of controlled vocabulary and text words related to p CLE, confocal, endomicroscopy, probe-based confocal laser endomicroscopy, and bile duct to identify reports of trials. In addition, recursive searches and crossreferencing was performed, and manual searches of articles identified after the initial search was also completed. We included fully published articles and those in abstract form. Given the relatively recent introduction of CLE we included randomized trials and cohort studies.R E S U LT S : In the evaluation of indeterminate pancreatobiliary strictures CLE with ERCP compared to ERCP alone can increase the detection of cancerous strictures with a sensitivity of(98% vs 45%) andhas a negative predictive value(97% vs 69%), but decreased the specificity(67% vs 100%) and the positive predictive value(71% vs 100%) when compared to index pathology. Modifications in the classification systems in indeterminate biliary strictures have increased the specificity of p CLE from 67% to 73%. In pancreatic cystic lesions there is a need to develop similar systems to interpret and characterize lesions based on CLE images obtained. The presence of superficial vascular network predicts serous cystadenomas accurately. Also training in acquiring and interpretation of images is feasible in those without any prior knowledge in CLE in a relatively simple manner and computer-aided diagnosis software is a promising innovation. CONCLUSION: The role of p CLE in the evaluation of pancreatobiliary disorders might be better suited for those with an intermediate and low probability.展开更多
Gastrointestinal cancers represent a major cause of morbidity and mortality,with incomplete response to chemotherapy in the advanced stages and poor prognosis.Angiogenesis plays a crucial part in tumor growth and meta...Gastrointestinal cancers represent a major cause of morbidity and mortality,with incomplete response to chemotherapy in the advanced stages and poor prognosis.Angiogenesis plays a crucial part in tumor growth and metastasis,with most gastrointestinal cancers depending strictly on the development of a new and devoted capillary network.Confocal laser endomicroscopy is a new technology which allows in vivo microscopic analysis of the gastrointestinal mucosa and its microvascularization during ongoing endoscopy by using topically or systemically administered contrast agents.Targeting markers of angiogenesis in association with confocal laser endomicroscopic examination(immunoendoscopy),as a future challenge,will add functional analysis to the morphological aspect of the neoplastic process.This review describes previous experience in endomicroscopic examination of the upper and lower digestive tract with emphasis on vascularization,resulting in a broad spectrum of potential clinical applications,and also preclinical research that could be translated to human studies.展开更多
Since its inception, endoscopy has aimed to establish an immediate diagnosis that is virtually consistent with a histologic diagnosis. In the past decade, confocal laser scanning microscopy has been brought into endos...Since its inception, endoscopy has aimed to establish an immediate diagnosis that is virtually consistent with a histologic diagnosis. In the past decade, confocal laser scanning microscopy has been brought into endoscopy, thus enabling in vivo microscopic tissue visualization with a magnification and resolution comparable to that obtained with the ex vivo microscopy of histological specimens. The major challenge in the development of instrumentation lies in the miniaturization of a fiber-optic probe for microscopic imaging with micron-scale resolution. Here, we present the design and construction of a confocal endoscope based on a fiber bundle with 1.4-μm lateral resolution and 8-frames per second(fps) imaging speed. The fiber-optic probe has a diameter of 2.6 mm that is compatible with the biopsy channel of a conventional endoscope. The prototype of a confocal endoscope has been used to observe epithelial cells of the gastrointestinal tracts of mice and will be further demonstrated in clinical trials. In addition, the confocal endoscope can be used for translational studies of epithelial function in order to monitor how molecules work and how cells interact in their natural environment.展开更多
AIM:To support probe-based confocal laser endomi-croscopy (pCLE) diagnosis by designing software for the automated classification of colonic polyps. METHODS:Intravenous fluorescein pCLE imaging of colorectal lesions w...AIM:To support probe-based confocal laser endomi-croscopy (pCLE) diagnosis by designing software for the automated classification of colonic polyps. METHODS:Intravenous fluorescein pCLE imaging of colorectal lesions was performed on patients under-going screening and surveillance colonoscopies, followed by polypectomies. All resected specimens were reviewed by a reference gastrointestinal pathologist blinded to pCLE information. Histopathology was used as the criterion standard for the differentiation between neoplastic and non-neoplastic lesions. The pCLE video sequences, recorded for each polyp, were analyzed off-line by 2 expert endoscopists who were blinded to the endoscopic characteristics and histopathology. These pCLE videos, along with their histopathology diagnosis, were used to train the automated classification software which is a content-based image retrieval technique followed by k-nearest neighbor classification. The performance of the off-line diagnosis of pCLE videos established by the 2 expert endoscopists was compared with that of automated pCLE software classification. All evaluations were performed using leave-one-patient- out cross-validation to avoid bias. RESULTS:Colorectal lesions (135) were imaged in 71 patients. Based on histopathology, 93 of these 135 lesions were neoplastic and 42 were non-neoplastic. The study found no statistical significance for the difference between the performance of automated pCLE software classification (accuracy 89.6%, sensitivity 92.5%, specificity 83.3%, using leave-one-patient-out cross-validation) and the performance of the off-line diagnosis of pCLE videos established by the 2 expert endoscopists (accuracy 89.6%, sensitivity 91.4%, specificity 85.7%). There was very low power (< 6%) to detect the observed differences. The 95% confidence intervals for equivalence testing were:-0.073 to 0.073 for accuracy, -0.068 to 0.089 for sensitivity and -0.18 to 0.13 for specificity. The classification software proposed in this study is not a "black box" but an informative tool based on the query by example model that produces, as intermediate results, visually similar annotated videos that are directly interpretable by the endoscopist. CONCLUSION:The proposed software for automated classification of pCLE videos of colonic polyps achieves high performance, comparable to that of off-line diagnosis of pCLE videos established by expert endoscopists.展开更多
AIM: To evaluate a newly developed hand-held confocal probe for in vivo microscopic imaging of the complete gastrointestinal tract in rodents. METHODS: A novel rigid confocal probe (diameter 7 mm) was designed wit...AIM: To evaluate a newly developed hand-held confocal probe for in vivo microscopic imaging of the complete gastrointestinal tract in rodents. METHODS: A novel rigid confocal probe (diameter 7 mm) was designed with optical features similar to the flexible endomicroscopy system for use in humans using a 488 nm single line laser for fluorophore excitation, Light emission was detected at 505 to 750 nm. The field of view was 475 μm × 475 μm. Optical slice thickness was 7 μm with a lateral resolution of 0.7 μm. Subsurface serial images at different depths (surface to 250 μm) were generated in real time at 1024 × 1024 pixels (0.8 frames/s) by placing the probe onto the tissue in gentle, stable contact. Tissue specimens were sampled for histopathological correlation.RESULTS: The esophagus, stomach, small and large intestine and meso, liver, pancreas and gall bladder were visualised in vivo at high resolution in n = 48 mice. Real time microscopic imaging with the confocal minimicroscopy probe was easy to achieve. The different staining protocols (fluorescein, acriflavine, FITC-labelled dextran and L. esculentum lectin) each highlighted specific aspects of the tissue, and in vivo imaging correlated excellently with conventional histology. In vivo blood flow monitoring added a functional quality to morphologic imaging.CONCLUSION: Confocal microscopy is feasible in vivo allowing the visualisation of the complete GI tract at high resolution even of subsurface tissue structures. The new confocal probe design evaluated in this study is compatible with laparoscopy and significantly expands the field of possible applications to intra-abdominal organs. It allows immediate testing of new in vivo staining and application options and therefore permits rapid transfer from animal studies to clinical use in patients.展开更多
While flexible endoscopy is essential for macroscopic evaluation,confocal laser endomicroscopy(CLE)has recently emerged as an endoscopic method enabling visualization at a cellular level.Two systems are currently avai...While flexible endoscopy is essential for macroscopic evaluation,confocal laser endomicroscopy(CLE)has recently emerged as an endoscopic method enabling visualization at a cellular level.Two systems are currently available,one based on miniprobes that can be inserted via a conventional endoscope or via a needle guided by endoscopic ultrasound.The second system has a confocal microscope integrated into the distal part of an endoscope.By adding molecular probes like fluorescein conjugated antibodies or fluorescent peptides to this procedure(either topically or systemically administered during on-going endoscopy),a novel world of molecular evaluation opens up.The method of molecular CLE could potentially be used for estimating the expression of important receptors in carcinomas,subsequently resulting in immediate individualization of treatment regimens,but also for improving the diagnostic accuracy of endoscopic procedures by identifying otherwise invisible mucosal lesions.Furthermore,studies have shown that fluorescein labelled drugs can be used to estimate the affinity of the drug to a target organ,which probably can be correlated to the efficacy of the drug.However,several of the studies in this research field have been conducted in animal facilities or in vitro,while only a limited number of trials have actually been carried out in vivo.Therefore,safety issues still needs further evaluations.This review will present an overview of the implications and pitfalls,as well as future challenges of molecular CLE in gastrointestinal diseases.展开更多
Technological advances and the widespread use of medical imaging have led to an increase in the identification of pancreatic cysts in patients who undergo crosssectional imaging. Current methods for the diagnosis and ...Technological advances and the widespread use of medical imaging have led to an increase in the identification of pancreatic cysts in patients who undergo crosssectional imaging. Current methods for the diagnosis and risk-stratification of pancreatic cysts are suboptimal, resulting in both unnecessary surgical resection and overlooked cases of neoplasia. Accurate diagnosis is crucial for guiding how a pancreatic cyst is managed, whether with surveillance for low-risk lesions or surgical resection for high-risk lesions. This review aims to summarize the current literature on confocal endomicroscopy and cyst fluid molecular analysis for the evaluation of pancreatic cysts. These recent technologies are promising adjuncts to existing approaches with the potential to improve diagnostic accuracy and ultimately patient outcomes.展开更多
基金The Health Science and Technology Foundation of Inner Mongolia,No.202201436Science and Technology Innovation Foundation of Inner Mongolia,No.CXYD2022BT01.
文摘BACKGROUND In recent years,confocal laser endomicroscopy(CLE)has become a new endoscopic imaging technology at the microscopic level,which is extensively performed for real-time in vivo histological examination.CLE can be performed to distinguish benign from malignant lesions.In this study,we diagnosed using CLE an asymptomatic patient with poorly differentiated gastric adenocarcinoma.CASE SUMMARY A 63-year-old woman was diagnosed with gastric mucosal lesions,which may be gastric cancer,in the small curvature of the stomach by gastroscopy.She consented to undergo CLE for morphological observation of the gastric mucosa.Through the combination of CLE diagnosis and postoperative pathology,the intraoperative CLE diagnosis was considered to be reliable.According to our experience,CLE can be performed as the first choice for the diagnosis of gastric cancer.CONCLUSION CLE has several advantages over pathological diagnosis.We believe that CLE has great potential in the diagnosis of benign and malignant gastric lesions.
基金Supported by the National Natural Science Foundation of China(No.82371058)the Natural Science Foundation of Shandong Province(No.ZR2020MH172)+2 种基金the Ophthalmology New Technology Incubation Fund Program(Ophthalmology Incubation Fund Phase II Project[2022]No.[005])Medicine Science and Technology Development Program of Shandong Province(No.202107020108)Qingdao Science and Technology Beneficiary Program(No.24-1-8-smjk-16-nsh).
文摘AIM:To evaluate the effects of antiglaucoma eye drops on corneal nerves by in vivo confocal microscopy(IVCM).METHODS:This study comprised 79 patients diagnosed with glaucoma and 16 healthy control individuals.Among the glaucoma patients,54 were treated with medication,while 25 remained untreated.Central corneal images were evaluated by IVCM,and then ACCMetrics was used to calculate the following parameters:corneal nerve fiber density(CNFD),branch density(CNBD),fiber length(CNFL),total branch density(CTBD),fiber area(CNFA),fiber width(CNFW),and fractal dimension(CNFrD).The correlation between IVCM parameters and drugs was evaluated using non-parametric measurements of Spearman’s rank correlation coefficient.RESULTS:The CNFD was reduced in glaucoma groups compared to healthy subjects(P<0.01).Patients using anti-glaucoma medications exhibited poorer confocal parameters compared to untreated patients.As the number of medications and usage count increased,CNFD,CNBD,CNFL,CTBD,CNFA,and CNFrD experienced a decline,while CNFW increased(all P<0.01).For the brinzolamide-therapy group,there was a significant decrease in CNFD and CNFL compared to the other monotherapy groups(P<0.001).In the absence of medication,CNFD in males was lower than that in females(P<0.05).Among patients under medication therapy,CNFD remained consistent between males and females.CONCLUSION:Antiglaucoma eye drops affect the microstructure of corneal nerves.IVCM and ACCMetrics are useful tools that could be used to evaluate the corneal nerve changes.
文摘Gastric cancer(GC)is a multifactorial disease,where both environmental and genetic features can have an impact on its occurrence and development.GC represents one of the leading causes of cancer-related deaths worldwide.GC is most frequent in males and is believed to arise from a series of premalignant lesions.The detection of GC at an early stage is crucial because early GC,which is an invasive stomach cancer confined to the mucosal or submucosal lining,may be curable with a reported 5-year survival rate of more than 90%.Advanced GC usually has a poor prognosis despite current treatment standards.The diagnostic efficacy of conventional endoscopy(with light endoscopy)is currently limited.Confocal laser endomicroscopy is a novel imaging technique that allows real-time in vivo histological examination of mucosal surfaces during endoscopy.Confocal laser endomicroscopy may be of great importance in the surveillance of precancerous gastric lesions and in the diagnosis of GC.In this editorial we commented on the article about this topic published by Lou et al in the recent issue of the World Journal of Clinical Cases.
文摘Confocal laser endomicroscopy(CLE)is a novel endoscopic modality that provides real-time histological information via high-resolution magnified view of the mucosa.CLE has a higher sensitivity,specificity,and diagnostic accuracy in detecting atrophic gastritis as compared to chromoendoscopy and narrow-band imaging.It can even predict low-grade and high-grade intraepithelial neoplasia by analyzing gastric pit patterns.CLE may have some advantages over the standard biopsy protocol,such as higher diagnostic yield and fewer biopsy requirements.Its diagnostic accuracy in detecting superficial gastric cancer is higher than that of white-light endoscopy.Inherent limitations,such as a narrow field of vision,can be surpassed by technological advancements and integration with other detection methods.Artificial intelligence holds promise in automated analysis of histopathological images.Thus,CLE can be helpful in screening for early gastric cancer and may help reduce the risk of complications from repeated biopsies,such as mucosal damage,bleeding,and infection.
基金support of the following research Projects (Nos.GZ:LE 992/14-3 and LE 992/18-1)by the Deutsche Forschungsgemeinschaft and the EMPIR program (project TracOptic,20IND07)co-financed by the European Union’s Horizon 2020 Research and Innovation Program.
文摘We present a unified electromagnetic modeling of coherence scanning interferometry,confocal microscopy,and focus variation microscopy as the most common techniques for surface topography inspection with micro-and nanometer resolution.The model aims at analyzing the instrument response and predicting systematic deviations.Since the main focus lies on the modeling of the microscopes,the light–surface interaction is considered,based on the Kirchhoff approximation extended to vectorial imaging theory.However,it can be replaced by rigorous methods without changing the microscope model.We demonstrate that all of the measuring instruments mentioned above can be modeled using the same theory with some adaption to the respective instrument.For validation,simulated results are confirmed by comparison with measurement results.
基金Project(08dj1400402) supported by the Major Program for the Fundamental Research of Shanghai Committee of Science and Technology, China
文摘The solidification process of a conventional superalloy, IN718, was investigated by confocal scanning laser microscope (CSLM). The liquid fraction during solidification was obtained as a function of real time and temperature in reference with the in-situ observation. The characteristics of L→γ transformation were analyzed and the γ growing rate of each stage was also calculated. Scheil equation was employed to predict the segregation behavior, and the predict results are in consistence with the experimental results. As a result, the confocal scanning laser microscope shows a great potential for solidification process research.
文摘The interphase nuclei of parenchyma cells and epidermal cells of garlic ( Allium sativum L.) clove were labelled with rabbit anti_actin antibody and FITC_conjugated goat anti_rabbit IgG antibody. The authors observed results with fluorescence microscopy and confocal laser scanning microscopy. The nuclei showed prominent green_yellow fluorescence, indicating the presence of actin in the nuclei. Fluorescence examination with TRITC_phalloidin showed distinctive red fluorescence in the nuclei, indicating that F_actin is present in the nuclei. Confocal laser scanning microscopy indicated the presence of F_actin containing network structures in the nuclei, but the network structures were absent and the nuclei still showed red fluorescence when the cells were treated with cytochalasin D before fixation; the red fluorescence in the nuclei was hard to be observed when the cells were treated with unlabelled phalloidin before the cells were stained with TRITC_phalloidin. These results indicate that F_actin is in the nuclei and forms network structures in the nuclei of garlic cells.
文摘A whole-field 3D surface measurement system for semiconductor wafer inspection is described.The system consists of an optical fiber plate,which can split the light beam into N^2 subbeams to realize the whole-field inspection.A special prism is used to separate the illumination light and signal light.This setup is characterized by high precision,high speed and simple structure.
基金Supported by A Program from Clinical Projects of Ministry of Health of China (2007) and Taishan Scholar Program of Shandong Province
文摘AIM: To classify the histological severity of Helicobacter pylori (H. pylori) infection-associated gastritis by confocal laser endomicroscopy (CLE). METHODS: Patients with upper gastrointestinal symptoms or individuals who were screened for gastric cancer were enrolled in this study. Histological severity of H. pylori infection-associated gastritis was graded according to the established CLE criteria. Diagnostic value of CLE for histo-logical gastritis was investigated and compared with that of white light endoscopy (WLE). Targeted biopsies from the sites observed by CLE were performed. RESULTS: A total of 118 consecutive patients with H. pylori infection-associated gastritis were enrolled in this study. Receiver operating characteristic curve analysis showedthat the sensitivity and specifi city of CLE were 82.9% and 90.9% for the diagnosis of H. pylori infection, 94.6% and 97.4% for predicting gastric normal mucosa, 98.5% and 94.6% for predicting histological active inflammation, 92.9% and 95.2% for predicting glan-dular atrophy, 98.6% and 100% for diagnosing intes-tinal metaplasia, respectively. Post-CLE image analysis showed that goblet cells and absorptive cells were the two most common parameters on the CLE-diagnosed intestinal metaplasia (IM) images (P < 0.001). More his-tological lesions of the stomach could be found by CLE than by WLE (P < 0.001). CONCLUSION: CLE can accurately show the histological severity of H. pylori infection-associated gastritis. Mapping IM by CLE has a rather good diagnostic accuracy.
文摘In Japan and countries such as South Korea and Tai-wan, China, the standard technique for detecting earlygastric cancer (EGC) is chromoendoscopy. This technique involves a magnified endoscope and the use ofan indigo-carmine spray to distinguish between EGCand non-EGC areas. However, this technique is notwidely adopted in many parts of the world. One important reason for limited use is that this technique needsan experienced endoscopist to interpret the imagesduring the procedure. In addition, the sensitivity for detecting gastric intestinal metaplasia (GIM), a precancerous lesion of EGC, is graded as suboptimal. Moreover,the requirement of a cumbersome spraying method isinconvenient and needs preparation time. Easier digitalchromoendoscopy techniques, such as Narrow-bandImaging and Flexible spectral Imaging Color Enhancement, have been reported to facilitate targeted GIM and EGC biopsy. They provide higher sensitivities over conventional white light endoscopy. Recently, the noveltechnology of confocal laser endomicroscopy has been introduced as a high-magnification (1000 ×) real-time evaluation for many early gastrointestinal (GI) cancersand precancerous GI lesions, including colonic polyp,Barrett's esophagus, and GIM. The advantage of this technique is that it can be used as an in vivo confirmation of the presence of GIM and EGC during endoscopic surveillance. This review aims to explain the current information on the usefulness of digital chromoendos-copy and confocal laser endomicroscopy for evaluating GIM and EGC during endoscopic surveillance and the possible future role of these techniques for GI cancerscreening programs.
文摘AIM:To evaluate the diagnosis of different differentiated gastric intraepithelial neoplasia (IN) by magnifica-tion endoscopy combined with narrow-band imaging (ME-NBI) and confocal laser endomicroscopy (CLE). METHODS:Eligible patients with suspected gastric IN lesions previously diagnosed by endoscopy in secondary hospitals and scheduled for further diagnosis and tratment were recruited for this study. Excluded from the study were patients who had liver cirrhosis, impaired renal function, acute gastrointestinal (GI) bleeding, coagulopathy, esophageal varices, jaundice, and GI post-surgery. Also excluded were those who were pregnant, breastfeeding, were younger than 18 years old, or were unable to provide informed consent. All patients had all mucus and bile cleared from their stom-achs. They then received upper GI endoscopy. When a mucosal lesion is found during observation with whitelight imaging, the lesion is visualized using maximal magnification, employing gradual movement of the tip of the endoscope to bring the image into focus. Saved images are analyzed. Confocal images were evaluated by two endoscopists (Huang J and Li MY), who were familiar with CLE, blinded to the related information about the lesions, and asked to classify each lesion as either a low grade dysplasia (LGD) or high grade dysplasia (HGD) according to given criteria. The results were compared with the final histopathologic diagnosis. ME-NBI images were evaluated by two endoscopists (Lu ZS and Ling-Hu EQ) who were familiar with NBI, blinded to the related information about the lesions and CLE images, and were asked to classify each lesion as a LGD or HGD according to the "microvascular pattern and surface pattern" classification system. The results were compared with the final histopathologic diagnosis. RESULTS: The study included 32 pathology-proven low grade gastric IN and 26 pathology-proven high grade gastric IN that were detected with any of the modalities. CLE and ME-NBI enabled clear visualization of the vascular microsurface patterns and microvascular structures of the gastric mucosa. The accuracy of the CLE and the ME-NBI diagnosis was 88% (95% CI:78%-98%) and 81% (95% CI: 69%-93%), respectively. The kappa coefficient of agreement between the histopathology and the in vivo CLE imaging was 0.755; between the histopathology and the in vivo CLE imaging was 0.615. McNemar's test (binomial distribution used) indicated that the agreement was significant (P < 0.05). When patients were diagnosed by MENBI with CLE, the overall accuracy of the diagnosis was 86.21% (95% CI:73%-96%), and the kappa coefficient of agreement was 0.713, according to McNemar's test (P < 0.05). CONCLUSION:Higher diagnostic accuracy, sensitivityand specificity of CLE over ME-NBI indicate the feasibility of these two techniques for the efficacious diagnostic classification of gastric IN.
文摘Recent technological advances in miniaturization have allowed for a confocal scanning microscope to be integrated into a conventional flexible endoscope,or into trans-endoscopic probes,a technique now known as confocal endomicroscopy or confocal laser endomicroscopy.This newly-developed technology has enabled endoscopists to collect real-time in vivo histological images or "virtual biopsies" of the gastrointestinal mucosa during endoscopy,and has stimulated significant interest in the application of this technique in clinical gastroenterology.This review aims to evaluate the current data on the technical aspects and the utility of this new technology in clinical gastroenterology and its potential impact in the future,particularly in the screening or surveillance of gastrointestinal neoplasia.
文摘AIM To investigate the application of confocallaser scanning microscopy(CLSM)in tumorpathology and three-dimensional( 3-D )reconstruction by CLSM in pathologic specimensof hepatocellular carcinoma(HCC).METHODS The 30μm thick sections were cutfrom the paraffin-embedded tissues of HCC,hyperplasia and normal liver,stained with DNAfluorescent probe YOYO-1 iodide and examinedby CLSM to collect optical sections of nuclei and3-D images reconstructed.RESULTS HCC displayed chaotic arrangementof carcinoma cell nuclei,marked pleomorphism,indented and irregular nuclear surface,andirregular and coarse chromatin texture.CONCLUSION The serial optical tomograms ofCLSM can be used to create 3-D reconstruction ofcancer cell nuclei.Such 3-D impressions mightbe helpful or even essential in making anaccurate diagnosis.
基金Supported by Deanship of Scientific Research at King Saud University through the Research Group Project number RGPVPP-279
文摘AIM:To review applications of confocal laser endomicroscopy(CLE) in pancreatobiliary lesions and studies that assessed training and interpretation of images. METHODS: A computerized literature search was performed using OVID MEDLINE, EMBASE, Cochrane library, and the ISI Web of Knowledge from 1980 to October 2014. We also searched abstracts from major meetings that included the Digestive Disease Week, Canadian Digestive Disease Week and the United European Gastroenterology Week using a combination of controlled vocabulary and text words related to p CLE, confocal, endomicroscopy, probe-based confocal laser endomicroscopy, and bile duct to identify reports of trials. In addition, recursive searches and crossreferencing was performed, and manual searches of articles identified after the initial search was also completed. We included fully published articles and those in abstract form. Given the relatively recent introduction of CLE we included randomized trials and cohort studies.R E S U LT S : In the evaluation of indeterminate pancreatobiliary strictures CLE with ERCP compared to ERCP alone can increase the detection of cancerous strictures with a sensitivity of(98% vs 45%) andhas a negative predictive value(97% vs 69%), but decreased the specificity(67% vs 100%) and the positive predictive value(71% vs 100%) when compared to index pathology. Modifications in the classification systems in indeterminate biliary strictures have increased the specificity of p CLE from 67% to 73%. In pancreatic cystic lesions there is a need to develop similar systems to interpret and characterize lesions based on CLE images obtained. The presence of superficial vascular network predicts serous cystadenomas accurately. Also training in acquiring and interpretation of images is feasible in those without any prior knowledge in CLE in a relatively simple manner and computer-aided diagnosis software is a promising innovation. CONCLUSION: The role of p CLE in the evaluation of pancreatobiliary disorders might be better suited for those with an intermediate and low probability.
基金Supported by Research Grant,No.239/2007,entitled OCTEUS,financed by the CNCSIS Romaniaby the Sectoral Operational Programme Human Resources Development (SOP HRD),financed from the European Social Fundby the RomanianGovernment under the contract number POSDRU/89/1.5/S/64109
文摘Gastrointestinal cancers represent a major cause of morbidity and mortality,with incomplete response to chemotherapy in the advanced stages and poor prognosis.Angiogenesis plays a crucial part in tumor growth and metastasis,with most gastrointestinal cancers depending strictly on the development of a new and devoted capillary network.Confocal laser endomicroscopy is a new technology which allows in vivo microscopic analysis of the gastrointestinal mucosa and its microvascularization during ongoing endoscopy by using topically or systemically administered contrast agents.Targeting markers of angiogenesis in association with confocal laser endomicroscopic examination(immunoendoscopy),as a future challenge,will add functional analysis to the morphological aspect of the neoplastic process.This review describes previous experience in endomicroscopic examination of the upper and lower digestive tract with emphasis on vascularization,resulting in a broad spectrum of potential clinical applications,and also preclinical research that could be translated to human studies.
基金supported by the National Key Technology R&D Program of China (2011BAI12B06)National Natural Science Foundation of China (61205197 and 61178077)
文摘Since its inception, endoscopy has aimed to establish an immediate diagnosis that is virtually consistent with a histologic diagnosis. In the past decade, confocal laser scanning microscopy has been brought into endoscopy, thus enabling in vivo microscopic tissue visualization with a magnification and resolution comparable to that obtained with the ex vivo microscopy of histological specimens. The major challenge in the development of instrumentation lies in the miniaturization of a fiber-optic probe for microscopic imaging with micron-scale resolution. Here, we present the design and construction of a confocal endoscope based on a fiber bundle with 1.4-μm lateral resolution and 8-frames per second(fps) imaging speed. The fiber-optic probe has a diameter of 2.6 mm that is compatible with the biopsy channel of a conventional endoscope. The prototype of a confocal endoscope has been used to observe epithelial cells of the gastrointestinal tracts of mice and will be further demonstrated in clinical trials. In addition, the confocal endoscope can be used for translational studies of epithelial function in order to monitor how molecules work and how cells interact in their natural environment.
文摘AIM:To support probe-based confocal laser endomi-croscopy (pCLE) diagnosis by designing software for the automated classification of colonic polyps. METHODS:Intravenous fluorescein pCLE imaging of colorectal lesions was performed on patients under-going screening and surveillance colonoscopies, followed by polypectomies. All resected specimens were reviewed by a reference gastrointestinal pathologist blinded to pCLE information. Histopathology was used as the criterion standard for the differentiation between neoplastic and non-neoplastic lesions. The pCLE video sequences, recorded for each polyp, were analyzed off-line by 2 expert endoscopists who were blinded to the endoscopic characteristics and histopathology. These pCLE videos, along with their histopathology diagnosis, were used to train the automated classification software which is a content-based image retrieval technique followed by k-nearest neighbor classification. The performance of the off-line diagnosis of pCLE videos established by the 2 expert endoscopists was compared with that of automated pCLE software classification. All evaluations were performed using leave-one-patient- out cross-validation to avoid bias. RESULTS:Colorectal lesions (135) were imaged in 71 patients. Based on histopathology, 93 of these 135 lesions were neoplastic and 42 were non-neoplastic. The study found no statistical significance for the difference between the performance of automated pCLE software classification (accuracy 89.6%, sensitivity 92.5%, specificity 83.3%, using leave-one-patient-out cross-validation) and the performance of the off-line diagnosis of pCLE videos established by the 2 expert endoscopists (accuracy 89.6%, sensitivity 91.4%, specificity 85.7%). There was very low power (< 6%) to detect the observed differences. The 95% confidence intervals for equivalence testing were:-0.073 to 0.073 for accuracy, -0.068 to 0.089 for sensitivity and -0.18 to 0.13 for specificity. The classification software proposed in this study is not a "black box" but an informative tool based on the query by example model that produces, as intermediate results, visually similar annotated videos that are directly interpretable by the endoscopist. CONCLUSION:The proposed software for automated classification of pCLE videos of colonic polyps achieves high performance, comparable to that of off-line diagnosis of pCLE videos established by expert endoscopists.
基金Supported by Group for Minimal-invasive Chirurgie, Johannes Gutenberg-Universitat, Mainz, Germany
文摘AIM: To evaluate a newly developed hand-held confocal probe for in vivo microscopic imaging of the complete gastrointestinal tract in rodents. METHODS: A novel rigid confocal probe (diameter 7 mm) was designed with optical features similar to the flexible endomicroscopy system for use in humans using a 488 nm single line laser for fluorophore excitation, Light emission was detected at 505 to 750 nm. The field of view was 475 μm × 475 μm. Optical slice thickness was 7 μm with a lateral resolution of 0.7 μm. Subsurface serial images at different depths (surface to 250 μm) were generated in real time at 1024 × 1024 pixels (0.8 frames/s) by placing the probe onto the tissue in gentle, stable contact. Tissue specimens were sampled for histopathological correlation.RESULTS: The esophagus, stomach, small and large intestine and meso, liver, pancreas and gall bladder were visualised in vivo at high resolution in n = 48 mice. Real time microscopic imaging with the confocal minimicroscopy probe was easy to achieve. The different staining protocols (fluorescein, acriflavine, FITC-labelled dextran and L. esculentum lectin) each highlighted specific aspects of the tissue, and in vivo imaging correlated excellently with conventional histology. In vivo blood flow monitoring added a functional quality to morphologic imaging.CONCLUSION: Confocal microscopy is feasible in vivo allowing the visualisation of the complete GI tract at high resolution even of subsurface tissue structures. The new confocal probe design evaluated in this study is compatible with laparoscopy and significantly expands the field of possible applications to intra-abdominal organs. It allows immediate testing of new in vivo staining and application options and therefore permits rapid transfer from animal studies to clinical use in patients.
基金Supported by ERC-like nr.7/2012 "Real-time Evaluation of Treatment Effects in Advanced Colorectal Carcinoma (REACT)",project ID PNII-CT-ERC-2012-1financed by the Executive Agency for Higher Education,Research,Development and Innovation Funding (CNCS-UEFISCDI)+2 种基金Romanian National Authority for Scientific Research,Ministry of National Education,ROMANIAEstablishment of confocal laser endomicroscopy in Copenhagen was possible due to the generous contributions of A.P.Moller and Chastine McKinney Mollers Foundation,Foundation Jochum,The Toyota Foundation and the Foundation of Aase and Ejnar DanielsenThe Foundation of Arvid Nilsson and The Lundbeck Foundation supported the activity of JGK and AS,respectively
文摘While flexible endoscopy is essential for macroscopic evaluation,confocal laser endomicroscopy(CLE)has recently emerged as an endoscopic method enabling visualization at a cellular level.Two systems are currently available,one based on miniprobes that can be inserted via a conventional endoscope or via a needle guided by endoscopic ultrasound.The second system has a confocal microscope integrated into the distal part of an endoscope.By adding molecular probes like fluorescein conjugated antibodies or fluorescent peptides to this procedure(either topically or systemically administered during on-going endoscopy),a novel world of molecular evaluation opens up.The method of molecular CLE could potentially be used for estimating the expression of important receptors in carcinomas,subsequently resulting in immediate individualization of treatment regimens,but also for improving the diagnostic accuracy of endoscopic procedures by identifying otherwise invisible mucosal lesions.Furthermore,studies have shown that fluorescein labelled drugs can be used to estimate the affinity of the drug to a target organ,which probably can be correlated to the efficacy of the drug.However,several of the studies in this research field have been conducted in animal facilities or in vitro,while only a limited number of trials have actually been carried out in vivo.Therefore,safety issues still needs further evaluations.This review will present an overview of the implications and pitfalls,as well as future challenges of molecular CLE in gastrointestinal diseases.
文摘Technological advances and the widespread use of medical imaging have led to an increase in the identification of pancreatic cysts in patients who undergo crosssectional imaging. Current methods for the diagnosis and risk-stratification of pancreatic cysts are suboptimal, resulting in both unnecessary surgical resection and overlooked cases of neoplasia. Accurate diagnosis is crucial for guiding how a pancreatic cyst is managed, whether with surveillance for low-risk lesions or surgical resection for high-risk lesions. This review aims to summarize the current literature on confocal endomicroscopy and cyst fluid molecular analysis for the evaluation of pancreatic cysts. These recent technologies are promising adjuncts to existing approaches with the potential to improve diagnostic accuracy and ultimately patient outcomes.