期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Evaluation of Air-Kerma and Absorbed Dose to Water for External Radiotherapy Beam Using Ionization Chamber
1
作者 Collins omondi Margaret Chege samson omondi 《Open Journal of Radiology》 2024年第3期113-124,共12页
Radiotherapy is the most widely applied oncologic treatment modality utilizing ionizing radiation. A high degree of accuracy, reliability and reproducibility is required for a successful treatment outcome. Measurement... Radiotherapy is the most widely applied oncologic treatment modality utilizing ionizing radiation. A high degree of accuracy, reliability and reproducibility is required for a successful treatment outcome. Measurement using ionization chamber is a prerequisite for absorbed dose determination for external beam radiotherapy. Calibration coefficient is expressed in terms of air kerma and absorbed dose to water traceable to Secondary Standards Dosimetry Laboratory. The objective of this work was to evaluate the level of accuracy of ionization chamber used for clinical radiotherapy beam determination. Measurement and accuracy determination were carried out according to IAEA TRS 398 protocol. Clinical farmers type ionization chamber measurement and National Reference standard from Secondary Standards Dosimetry Laboratory were both exposed to cobalt-60 beam and measurement results compared under the same environmental conditions. The accuracy level between National Reference Standard and clinical radiotherapy standard was found to be −1.92% and −2.02% for air kerma and absorbed dose to water respectively. To minimize the effect of error and maximize therapeutic dose during treatment in order to achieve required clinical outcome, calibration factor was determined for air kerma (Nk) as 49.7 mGy/nC and absorbed dose to water ND, as 52.9 mGy/nC. The study established that radiotherapy beam measurement chain is prone to errors. Hence there is a need to independently verify the accuracy of radiation dose to ensure precision of dose delivery. The errors must be accounted for during clinical planning by factoring in calibration factor to minimize the systematic errors during treatment, and thereby providing enough room to achieve ±5% dose delivery to tumor target as recommended by ICRU. 展开更多
关键词 Absorbed Dose to Water Air Kerma Co-60 Source Calibration SSDL Radiotherapy Beam METROLOGY Accuracy and Accuracy
在线阅读 下载PDF
Evaluation of Dosimetric Impact of Uncertainty of Measurement in Estimating External Radiotherapy Dose
2
作者 Collins omondi Margaret Chege samson omondi 《Open Journal of Applied Sciences》 2024年第8期1985-1995,共11页
Cancer is a major societal public health and economic problem, responsible for one in every six deaths. Radiotherapy is the main technique of treatment for more than half of cancer patients. To achieve a successful ou... Cancer is a major societal public health and economic problem, responsible for one in every six deaths. Radiotherapy is the main technique of treatment for more than half of cancer patients. To achieve a successful outcome, the radiation dose must be delivered accurately and precisely to the tumor, within ± 5% accuracy. Smaller uncertainties are required for better treatment outcome. The objective of the study is to investigate the uncertainty of measurement of external radiotherapy beam using a standard ionization chamber under reference conditions. Clinical farmers type ionization chamber measurement was compared against the National Reference standard, by exposing it in a beam 60Co gamma source. The measurement set up was carried out according to IAEA TRS 498 protocol and uncertainty of measurement evaluated according to GUM TEDDOC-1585. Evaluation and analysis were done for the identified subjects of uncertainty contributors. The expanded uncertainty associated with 56 mGy/nC ND,W was found to be 0.9% corresponding to a confidence level of approximately 95% with a coverage factor of k = 2. The study established the impact of dosimetry uncertainty of measurement in estimating external radiotherapy dose. The investigation established that the largest contributor of uncertainty is the stability of the ionization chamber at 36%, followed by temperature at 22% and positioning of the chamber in the beam at 8%. The effect of pressure, electrometer, resolution, and reproducibility were found to be minimal to the overall uncertainty. The study indicate that there is no flawless measurement, as there are many prospective sources of variation. Measurement results have component of unreliability and should be regarded as best estimates of the true value. . 展开更多
关键词 Absorbed Dose to Water RADIOTHERAPY Uncertainty of Measurement Secondary Standards Dosimetry Laboratory Ionizing Chamber
在线阅读 下载PDF
Assessment of Occupational Radiation Exposure for Radiotherapy Healthcare Workers at Kenyatta National Hospital Using Thermoluminescence Dosimeter LiF:Mg,Ti
3
作者 Collins omondi Margaret Chege samson omondi 《Journal of Geoscience and Environment Protection》 2024年第7期14-24,共11页
Kenyatta National Hospital (KNH) is the largest public referral hospital with a comprehensive cancer treatment facility in East and Central Africa. Occupational radiation monitoring is a significant technique for demo... Kenyatta National Hospital (KNH) is the largest public referral hospital with a comprehensive cancer treatment facility in East and Central Africa. Occupational radiation monitoring is a significant technique for demonstrating compliance of radiation regulatory limits. The objective of the study was to carry out assessment of occupational radiation exposure among radiotherapy personnel at KNH using thermoluminescence dosimeter, TLD. KNH staff were monitored using dosimeter type TLD-100 made of LiF:Mg,Ti, on monthly basis. The reader system used for analysis was Harshaw 8800. The measurement established the average monthly accumulated occupational personnel dose for KNH to be 0.21 mSv and 0.29 mSv for Hp (10) and Hp (0.07) respectively. The accumulated dose results were within the maximum acceptable dose of 1.67 mSv/month and 41.6 mSv/month for Hp (10) and Hp (0.07) respectively. The investigation results were higher than the acceptable public limit of 0.08 mSv/month. Moreover, incidences were noted where the fetus dose limit 0.42 was also exceeded. Evaluation of statistical dose exposure among doctors, nurses and radiographers’ measurement results were within ±0.02 mSv. The study established the average KNH occupational radiation exposure levels for both Hp (10) and Hp (0.07) were within the ICRU recommendation, validating radiation protection safe practice. Data analysis of healthcare workers did not indicate exposure trend biased to any healthcare profession. Hence radiation risk cut across all professional categories. It is recommended that Radiation Monitoring program be reviewed to include non-clinical staff who access the facility. Radiation reporting should not be limited to one facility, but reflect cases where workers are involved in multiple multiple jobs. 展开更多
关键词 Occupational Monitoring EXPOSURE Thermoluminescence Dosimeter and Radiotherapy
在线阅读 下载PDF
Diversity and distribution patterns of non-volant smallmammals along different elevation gradients on Mt. Kenya,Kenya 被引量:5
4
作者 Simon Musila Zhong-Zheng Chen +9 位作者 Quan Li Richard Yego Bin Zhang Kenneth Onditi Immaculate Muthoni Shui-Wang He samson omondi James Mathenge Esther N.Kioko Xue-Long Jiang 《Zoological Research》 SCIE CAS CSCD 2019年第1期53-60,共8页
The distribution of small mammals in mountainous environments across different elevations can provide important information on the effects of climate change on the dispersal of species. However, few studies conducted ... The distribution of small mammals in mountainous environments across different elevations can provide important information on the effects of climate change on the dispersal of species. However, few studies conducted on Afromontane ecosystems have compared the altitudinal patterns of small mammal diversity. We investigated the species diversity and abundance of non-volant small mammals(hereafter ‘small mammals')on Mt. Kenya, the second tallest mountain in Africa,using a standard sampling scheme. Nine sampling transects were established at intervals of 200 m on the eastern(Chogoria) and western(Sirimon) slopes.A total of 1 905 individuals representing 25 species of small mammals were trapped after 12 240 trap-nights.Abundance was highest at mid-elevations on both slopes.However, species richness and their distribution patterns differed between the two slopes. More species were recorded on Chogoria(24) than on Sirimon(17). On Chogoria, species richness was higher at mid-high elevations, with a peak at mid-elevation(2 800 m a.s.l.),whereas species richness showed little variation on the Sirimon slope. These results indicate that patterns of species diversity can differ between slopes on the same mountain. In addition, we extensively reviewed literature on Mt. Kenya's mammals and compiled a comprehensive checklist of 76 mammalian species. However, additional research is required to improve our understanding of smal mammal diversity in mountain habitats in Africa. 展开更多
关键词 Small MAMMALS Species richness ABUNDANCE ELEVATION Mt.Kenya
在线阅读 下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部