期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Diagnosis of obscure gastrointestinal bleeding by intraoperative enteroscopy in 81 consecutive patients 被引量:5
1
作者 ralf jakobs Dirk Hartmann +5 位作者 Claus Benz Dieter Schilling Uwe Weickert Axel Eickhoff Klaus Schoenleben Juergen F Riemann 《World Journal of Gastroenterology》 SCIE CAS CSCD 2006年第2期313-316,共4页
AIM: To analyze the results and complications of intraoperative enteroscopy (IOE) by investigating a series of selected patients with bleeding suspected to originate from the small intestine. METHODS: Eighty-one p... AIM: To analyze the results and complications of intraoperative enteroscopy (IOE) by investigating a series of selected patients with bleeding suspected to originate from the small intestine. METHODS: Eighty-one patients (mean age: 65 years) including 40 males (49.4%) and 41 females (50.6%) with obscure gastrointestinal bleeding underwent IOE between 1990 and 2004. The patients were identified from a database and data were selected from the patients' charts retrospectively. All the patients had undergone at least one non-diagnostic esophagogastroduodenoscopy, colonoscopy, standard enteroscopy and a negative abdominal ultrasound scan before IOE. RESULTS: The median minimal hemoglobin level in the patients was 59+15g/L and 72.8% of the patients required transfusion of packed erythrOoltes previously. A bleeding source was detected in 68 (84%) of the patients during IOE. Angiodysplasiae were found in 44 patients (54.3%) and 9 patients (11.1%) were affected by ulcers in the small intestine. A tumor in the small intestine was detected in another 6 patients. The treatment consisted of argon-plasma-coagulation, surgical suture or limited resection in most of the patients. CONCLUSION: Intra-operative enteroscopy is still used for the diagnosis of suspected small bowel bleeding. Recent developments such as wireless capsule endoscopy and double balloon enteroscopy, may lead to the replacement of IOE in the future. 展开更多
关键词 Obscure bleeding ENTEROSCOPY INTRAOPERATIVE Small intestine
在线阅读 下载PDF
Self-expanding metal stents for the palliation of malignant gastric outlet obstruction in patients with peritoneal carcinomatosis 被引量:2
2
作者 Christoph Rademacher Matthias Bechtler +3 位作者 Steffen Schneider Bettina Hartmann Johannes Striegel ralf jakobs 《World Journal of Gastroenterology》 SCIE CAS 2016年第43期9554-9561,共8页
AIM To evaluate the efficacy of self-expanding metal stents(SEMS) for the palliation of malignant gastric outlet obstruction in patients with and without peritoneal carcinomatosis(PC).METHODS We performed a retrospect... AIM To evaluate the efficacy of self-expanding metal stents(SEMS) for the palliation of malignant gastric outlet obstruction in patients with and without peritoneal carcinomatosis(PC).METHODS We performed a retrospective analysis of 62 patients who underwent SEMS placement for treatment of malignant gastroduodenal obstruction at our hospital over a six-year period. Stents were deployed through the scope under combined fluoroscopic and endoscopic guidance. Technical success was defined as successful stent placement and expansion. Clinical success was defined as an improvement in the obstructive symptoms and discharge from hospital without additional parenteral nutrition. According to carcinomatosis status, patients were assigned into groups with or without evidence of peritoneal disease.RESULTS In most cases, obstruction was caused by pancreatic(47%) or gastric cancer(23%). Technical success was achieved in 96.8%(60/62), clinical success in 79%(49/62) of all patients. Signs of carcinomatosis were identified in 27 patients(43.5%). The diagnosis was confirmed by pathology or previous operation in 7 patients(11.2%) and suspected by CT, MRI or ultrasound in 20 patients(32.2%). Presence of carcinomatosis was associated with a significantly lower clinical success rate compared to patients with no evidence of peritoneal disease(66.7% vs 88.6%, P = 0.036). There was no significant difference in overall survival between patients with or without PC(median 48 d vs 70 d, P = 0.21), but patients showed significantly longer survival after clinical success of SEMS placement compared to those experiencing clinical failure(median 14.5 d vs 75 d, P = 0.0003).CONCLUSION Given the limited therapeutic options and a clinical success rate of at least 66.7%, we believe that SEMS are a reasonable treatment option in patients with malignant gastric outlet obstruction with peritoneal carcinomatosis. 展开更多
关键词 Gastric outlet obstruction Self-expanding metal stents Peritoneal carcinomatosis PALLIATION ENDOSCOPY
在线阅读 下载PDF
PillCamColon2 after incomplete colonoscopy-A prospective multicenter study 被引量:1
3
作者 Peter Baltes Marc Bota +16 位作者 Jorg Albert Michael Philipper Hans-Georg Horster Friedrich Hagenmüller Ingo Steinbrück ralf jakobs Matthias Bechtler Dirk Hartmann Horst Neuhaus Jean-Pierre Charton Rupert Mayershofer Horst Hohn Thomas Rosch Stefan Groth Tanja Nowak Peter Wohlmuth Martin Keuchel 《World Journal of Gastroenterology》 SCIE CAS 2018年第31期3556-3566,共11页
AIM To evaluate the ability of PillCamColon2 to visualize colonic segments missed by incomplete optical colonoscopy(OC) and to assess the diagnostic yield.METHODS This prospective multicentre study included 81 patient... AIM To evaluate the ability of PillCamColon2 to visualize colonic segments missed by incomplete optical colonoscopy(OC) and to assess the diagnostic yield.METHODS This prospective multicentre study included 81 patients from nine centres who underwent second-generation colon capsule endoscopy(CCE) following incomplete OC performed by an experienced gastroenterologist(> 1000 colonoscopies). Patients with stenosis were excluded. According to patient preferences, CCE was performed the following day(protocol A) after staying on clear liquids and 0.75 L Moviprep in the morning or within 30 d after new split-dose Moviprep(protocol B). Boosts consisted of 0.75 L and 0.25 L Moviprep, and phospho-soda was given as a rescue if the capsule was not excreted after seven hours.RESULTS Seventy-four patients were analysed(51% of them in group A; 49% in group B). Bowel cleansing was adequate in 67% of cases, and CCE could visualize colonic segments missed by incomplete colonoscopy in 90% of patients under protocol A and 97% of patients under protocol B(P = 0.35, n.s.). Significant polyps including adenocarcinoma were detected in 24% of cases. Detection rates for all polyps and significant polyps per patient were similar in both protocols. Polyps were found predominantly in the right colon(86%) in segments that were not reached by OC. Extracolonic findings-such as reflux esophagitis, suspected Barrett esophagus, upper GI-bleeding, gastric polyps, gastric erosions and angiectasia-were detected in eight patients. Pill Cam Colon2 capsule was retained in the ileum of one patient(1.4%) without symptoms and removed during an uneventful resection for unknown Crohn's disease that was diagnosed as the cause of anemia, which was the indication for colonoscopy. CCE was well tolerated. One patient suffered from selflimiting vomiting after consuming the phospho-soda.CONCLUSION Second-generation CCE using a low-volume preparation is useful after incomplete OC, and it allows for the detection of additional relevant findings, but cleansing efficiency could be improved. 展开更多
关键词 Colon capsule endoscopy PillCamColon2 Incomplete colonoscopy Low volume prep Moviprep Phospho-soda Cleanliness level Complementation rate POLYPS
在线阅读 下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部