The construction and performance characteristics of a novel (diphenhydramine) DPH CC-sensor based on DZCE were reported in this work. The CC-membrane was prepared by incorporating of (diazacrown ether) DZCE and/or (te...The construction and performance characteristics of a novel (diphenhydramine) DPH CC-sensor based on DZCE were reported in this work. The CC-membrane was prepared by incorporating of (diazacrown ether) DZCE and/or (tetraflorophenyl borate) TFPB into a plasticized poly(vinyl chloride) membrane. The CC-sensor revealed a Nernstian behavior over a DPH-concentration range (9.1 × 10<sup>-3</sup> - 6.3 × 10<sup>-7</sup> mol ·L<sup>-1</sup>), and relatively low detection limit (1 × 10<sup>-7</sup> mol ·L<sup>-1</sup>). The potentiometric response was independent on the pH of the solution in the range of 7 - 10. The DPH-CC showed a very short response time (<5 s). It showed good selectivity towards different cations and pharmaceutical compounds. The relative selectivity coefficient was applied for evaluation of the selectivity properties of the DPH-CC. The DPH-CC was used successfully for determination of DPH in its samples. The found recovery range was 95% - 98.5%, and the standard deviation value ranged between 0.13 - 0.42. The DPH-CC facilitates the analysis of DPH directly without pretreatment and it can be built-in as a detector in chromatographic apparatus. It can be used as a tool for on-line monitoring of the drug levels.展开更多
The construction and performance characteristics of a novel Iron(III) membrane sensor based on (37-bis-[(diethoxy-thiophosphoryl)-oxy]-5,11,17,23,29,35-hexa-kis-(1,1-dimethylethyl)-calix[6]-arene-38,39,40,41,42-pentol...The construction and performance characteristics of a novel Iron(III) membrane sensor based on (37-bis-[(diethoxy-thiophosphoryl)-oxy]-5,11,17,23,29,35-hexa-kis-(1,1-dimethylethyl)-calix[6]-arene-38,39,40,41,42-pentol) (A) were reported in this paper. The sensor was prepared by incorporating compound (A) into a plasticized polyvinyl chloride PVC membrane. The electrode reveals a Nernstian behavior over a wide iron ion concentration range (1.0 × 10-2 - 1.0 × 10-4 mol·L-1), and relatively low detection limit (1.0 × 10-5 mol·L-1). The potentiometric response was independent on the pH of the solution in the range of 4 - 7. The electrode showed a very short response time (<5 s). It exhibited very good selectivity relative to a wide variety of metal cations. Correlation of selectivity coefficient values with ionic radii of interferent cations was discussed. The proposed iron- ISE was applied for analysis of iron containing samples with comparison to a recommended spectrophotometric method.展开更多
文摘The construction and performance characteristics of a novel (diphenhydramine) DPH CC-sensor based on DZCE were reported in this work. The CC-membrane was prepared by incorporating of (diazacrown ether) DZCE and/or (tetraflorophenyl borate) TFPB into a plasticized poly(vinyl chloride) membrane. The CC-sensor revealed a Nernstian behavior over a DPH-concentration range (9.1 × 10<sup>-3</sup> - 6.3 × 10<sup>-7</sup> mol ·L<sup>-1</sup>), and relatively low detection limit (1 × 10<sup>-7</sup> mol ·L<sup>-1</sup>). The potentiometric response was independent on the pH of the solution in the range of 7 - 10. The DPH-CC showed a very short response time (<5 s). It showed good selectivity towards different cations and pharmaceutical compounds. The relative selectivity coefficient was applied for evaluation of the selectivity properties of the DPH-CC. The DPH-CC was used successfully for determination of DPH in its samples. The found recovery range was 95% - 98.5%, and the standard deviation value ranged between 0.13 - 0.42. The DPH-CC facilitates the analysis of DPH directly without pretreatment and it can be built-in as a detector in chromatographic apparatus. It can be used as a tool for on-line monitoring of the drug levels.
文摘The construction and performance characteristics of a novel Iron(III) membrane sensor based on (37-bis-[(diethoxy-thiophosphoryl)-oxy]-5,11,17,23,29,35-hexa-kis-(1,1-dimethylethyl)-calix[6]-arene-38,39,40,41,42-pentol) (A) were reported in this paper. The sensor was prepared by incorporating compound (A) into a plasticized polyvinyl chloride PVC membrane. The electrode reveals a Nernstian behavior over a wide iron ion concentration range (1.0 × 10-2 - 1.0 × 10-4 mol·L-1), and relatively low detection limit (1.0 × 10-5 mol·L-1). The potentiometric response was independent on the pH of the solution in the range of 4 - 7. The electrode showed a very short response time (<5 s). It exhibited very good selectivity relative to a wide variety of metal cations. Correlation of selectivity coefficient values with ionic radii of interferent cations was discussed. The proposed iron- ISE was applied for analysis of iron containing samples with comparison to a recommended spectrophotometric method.