A derivative of thiazole(AAT) has been explored as a sensing material for preparation a selective Lu(III) PVC-based membrane sensor.The proposed sensor exhibits a Nernstian response over a wide concentration range...A derivative of thiazole(AAT) has been explored as a sensing material for preparation a selective Lu(III) PVC-based membrane sensor.The proposed sensor exhibits a Nernstian response over a wide concentration range from 1.0×10^(-6) to 1.0×10^(-1) mol/L of Lu(Ⅲ) and the detection limit is 5.7×10^(-7) mol/L.The sensor response is independent of pH of the solution in the range 3.2-8.8 and possesses the advantages of fast response time(~6) and in particular,good selectivity to the lutetium ions with regard to most common metal ions,and especially all lanthanide ions.展开更多
A simple and selective method using a column packed with graphene oxide(GO) as a solid phase extractant has been developed for the multi-element preconcentration of Fe(Ⅲ),Ni(Ⅱ),Cu(Ⅱ) and Zn(Ⅱ)ions prior ...A simple and selective method using a column packed with graphene oxide(GO) as a solid phase extractant has been developed for the multi-element preconcentration of Fe(Ⅲ),Ni(Ⅱ),Cu(Ⅱ) and Zn(Ⅱ)ions prior to flame atomic absorption spectrometric determinations.The method is based on the sorption of mentioned ions on synthesized GO using 2-(tert-butoxy)-N-(3-carbamothioylphenyl)acetamide as a chelating agent.Several parameters on the extraction and complex formation were optimized.Under the optimized conditions(pH 6,flow rate 9 mL/min),metal ions were retained on the column,then quantitatively eluted by HNO3solution(5 mL,3.0 mol/L).The preconcentration factor was calculated as250.The detection limits for the analyte ions of interest were found in the range of 0.11 ng/mL(Ni2+) to0.63 ng/mL(Cu2+).The column packed with GO was adequate for metal ions separation in matrixes containing alkali,alkaline earth,transition and heavy metal ions.展开更多
基金NFCRS,Nuclear Science&Technology Research Institute(Tehran,Iran)for their financial support
文摘A derivative of thiazole(AAT) has been explored as a sensing material for preparation a selective Lu(III) PVC-based membrane sensor.The proposed sensor exhibits a Nernstian response over a wide concentration range from 1.0×10^(-6) to 1.0×10^(-1) mol/L of Lu(Ⅲ) and the detection limit is 5.7×10^(-7) mol/L.The sensor response is independent of pH of the solution in the range 3.2-8.8 and possesses the advantages of fast response time(~6) and in particular,good selectivity to the lutetium ions with regard to most common metal ions,and especially all lanthanide ions.
文摘A simple and selective method using a column packed with graphene oxide(GO) as a solid phase extractant has been developed for the multi-element preconcentration of Fe(Ⅲ),Ni(Ⅱ),Cu(Ⅱ) and Zn(Ⅱ)ions prior to flame atomic absorption spectrometric determinations.The method is based on the sorption of mentioned ions on synthesized GO using 2-(tert-butoxy)-N-(3-carbamothioylphenyl)acetamide as a chelating agent.Several parameters on the extraction and complex formation were optimized.Under the optimized conditions(pH 6,flow rate 9 mL/min),metal ions were retained on the column,then quantitatively eluted by HNO3solution(5 mL,3.0 mol/L).The preconcentration factor was calculated as250.The detection limits for the analyte ions of interest were found in the range of 0.11 ng/mL(Ni2+) to0.63 ng/mL(Cu2+).The column packed with GO was adequate for metal ions separation in matrixes containing alkali,alkaline earth,transition and heavy metal ions.