期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
2-Amino-4-(4-aminophenyl)thiazole application as an ionophore in the construction of a Lu(Ⅲ) selective membrane sensor 被引量:1
1
作者 mohammad reza pourjavid Taherehsadat Razavi 《Chinese Chemical Letters》 SCIE CAS CSCD 2012年第3期343-346,共4页
A derivative of thiazole(AAT) has been explored as a sensing material for preparation a selective Lu(III) PVC-based membrane sensor.The proposed sensor exhibits a Nernstian response over a wide concentration range... A derivative of thiazole(AAT) has been explored as a sensing material for preparation a selective Lu(III) PVC-based membrane sensor.The proposed sensor exhibits a Nernstian response over a wide concentration range from 1.0×10^(-6) to 1.0×10^(-1) mol/L of Lu(Ⅲ) and the detection limit is 5.7×10^(-7) mol/L.The sensor response is independent of pH of the solution in the range 3.2-8.8 and possesses the advantages of fast response time(~6) and in particular,good selectivity to the lutetium ions with regard to most common metal ions,and especially all lanthanide ions. 展开更多
关键词 Membrane sensor Lu(Ⅲ) selective Thiazole derivative PVC POTENTIOMETRY
原文传递
Use of 2-(tert-butoxy)-N-(3-carbamothioylphenyl)acetamide and graphene oxide for separation and preconcentration of Fe(Ⅲ),Ni(Ⅱ),Cu(Ⅱ) and Zn(Ⅱ) ions in different samples 被引量:2
2
作者 mohammad reza pourjavid Ali Akbari Sehat +4 位作者 Majid Haji Hosseini mohammad rezaee Masoud Arabieh Seyed reza Yousefi mohammad reza Jamali 《Chinese Chemical Letters》 SCIE CAS CSCD 2014年第5期791-793,共3页
A simple and selective method using a column packed with graphene oxide(GO) as a solid phase extractant has been developed for the multi-element preconcentration of Fe(Ⅲ),Ni(Ⅱ),Cu(Ⅱ) and Zn(Ⅱ)ions prior ... A simple and selective method using a column packed with graphene oxide(GO) as a solid phase extractant has been developed for the multi-element preconcentration of Fe(Ⅲ),Ni(Ⅱ),Cu(Ⅱ) and Zn(Ⅱ)ions prior to flame atomic absorption spectrometric determinations.The method is based on the sorption of mentioned ions on synthesized GO using 2-(tert-butoxy)-N-(3-carbamothioylphenyl)acetamide as a chelating agent.Several parameters on the extraction and complex formation were optimized.Under the optimized conditions(pH 6,flow rate 9 mL/min),metal ions were retained on the column,then quantitatively eluted by HNO3solution(5 mL,3.0 mol/L).The preconcentration factor was calculated as250.The detection limits for the analyte ions of interest were found in the range of 0.11 ng/mL(Ni2+) to0.63 ng/mL(Cu2+).The column packed with GO was adequate for metal ions separation in matrixes containing alkali,alkaline earth,transition and heavy metal ions. 展开更多
关键词 Solid phase extraction Transition metals Graphene oxide Flame atomic absorption spectrometry
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部