Solid solutions of (1 - x)Al2TiO5-xMgTi2O5 (x = 0 - 1) doped with alkaline feldspar were prepared. Thermal decomposition largely depends on the feldspar doping as same as the x value. It was found that decomposition f...Solid solutions of (1 - x)Al2TiO5-xMgTi2O5 (x = 0 - 1) doped with alkaline feldspar were prepared. Thermal decomposition largely depends on the feldspar doping as same as the x value. It was found that decomposition free ceramics over 500 hours of heat treatment at 1100°C in an ambient atmosphere could be obtained for the feldspar-doped ceramics at x > 0.5 with a fracture strength of 33 - 40 MPa and coefficient of thermal expansion of 2.4 - 4.1 ×10-6K-1. A partial decomposition was observed for a compositional range of around x = 0.75. Both composition of the solid solution and an addition of the alkaline feldspar contributed synergistically to improve such thermal and mechanical properties. The decomposition free Al2TiO5-MgTi2O5 ceramics is expected for variety of high temperature applications including diesel particulate filters.展开更多
Background:To compare the arithmetic mean(M-SIA)and the summated vector mean of surgically induced astigmatism(SVM-SIA)according to the incision site after phakic intraocular lens(Visian implantable collamer lens(ICL)...Background:To compare the arithmetic mean(M-SIA)and the summated vector mean of surgically induced astigmatism(SVM-SIA)according to the incision site after phakic intraocular lens(Visian implantable collamer lens(ICL),STAAR Surgical)implantation.Methods:This study comprised 121 eyes of 121 consecutive patients undergoing ICL surgery through a 3.0-mm temporal or superior clear corneal incision.The magnitude and the axis of corneal astigmatism preoperatively and 3 months postoperatively were measured using an automated keratometer.The M-SIA and the SVM-SIA were determined according to the incision site.Results:The magnitude of corneal astigmatism significantly increased from 1.23±0.59 D preoperatively to 1.46±0.72 D postoperatively in the temporal incision group(Wilcoxon signed-rank test,P<0.001),but it significantly decreased from 1.09±0.36 D preoperatively to 0.86±0.41 D postoperatively in the superior incision group(P<0.001).The M-SIA was 0.48±0.30 D,and the SVM-SIA was 0.23±0.52 D at a meridian of 82°in the temporal incision group.The M-SIA was 0.57±0.30 D,and the SVM-SIA was 0.47±0.45 D at a meridian of 1°in the superior incision group.Conclusions:ICL implantation induces the M-SIA by approximately 0.5 D,but the SVM-SIA decreased to 50%and 80%of the M-SIA in magnitude through temporal and superior incisions,respectively.The direction of the SVM-SIA showed a tendency toward corneal flattening to the incisional site.It should be noted that the M-SIA is somewhat different from the SVM-SIA according to the incision site.展开更多
BackgroundTo compare the arithmetic mean (M-SIA) and the summated vector mean of surgically induced astigmatism (SVM-SIA) according to the incision site after phakic intraocular lens (Visian implantable collamer lens ...BackgroundTo compare the arithmetic mean (M-SIA) and the summated vector mean of surgically induced astigmatism (SVM-SIA) according to the incision site after phakic intraocular lens (Visian implantable collamer lens (ICL), STAAR Surgical) implantation.MethodsThis study comprised 121 eyes of 121 consecutive patients undergoing ICL surgery through a 3.0-mm temporal or superior clear corneal incision. The magnitude and the axis of corneal astigmatism preoperatively and 3 months postoperatively were measured using an automated keratometer. The M-SIA and the SVM-SIA were determined according to the incision site.ResultsThe magnitude of corneal astigmatism significantly increased from 1.23 ± 0.59 D preoperatively to 1.46 ± 0.72 D postoperatively in the temporal incision group (Wilcoxon signed-rank test, P < 0.001), but it significantly decreased from 1.09 ± 0.36 D preoperatively to 0.86 ± 0.41 D postoperatively in the superior incision group (P < 0.001). The M-SIA was 0.48 ± 0.30 D, and the SVM-SIA was 0.23 ± 0.52 D at a meridian of 82° in the temporal incision group. The M-SIA was 0.57 ± 0.30 D, and the SVM-SIA was 0.47 ± 0.45 D at a meridian of 1° in the superior incision group.ConclusionsICL implantation induces the M-SIA by approximately 0.5 D, but the SVM-SIA decreased to 50% and 80% of the M-SIA in magnitude through temporal and superior incisions, respectively. The direction of the SVM-SIA showed a tendency toward corneal flattening to the incisional site. It should be noted that the M-SIA is somewhat different from the SVM-SIA according to the incision site.展开更多
文摘Solid solutions of (1 - x)Al2TiO5-xMgTi2O5 (x = 0 - 1) doped with alkaline feldspar were prepared. Thermal decomposition largely depends on the feldspar doping as same as the x value. It was found that decomposition free ceramics over 500 hours of heat treatment at 1100°C in an ambient atmosphere could be obtained for the feldspar-doped ceramics at x > 0.5 with a fracture strength of 33 - 40 MPa and coefficient of thermal expansion of 2.4 - 4.1 ×10-6K-1. A partial decomposition was observed for a compositional range of around x = 0.75. Both composition of the solid solution and an addition of the alkaline feldspar contributed synergistically to improve such thermal and mechanical properties. The decomposition free Al2TiO5-MgTi2O5 ceramics is expected for variety of high temperature applications including diesel particulate filters.
文摘Background:To compare the arithmetic mean(M-SIA)and the summated vector mean of surgically induced astigmatism(SVM-SIA)according to the incision site after phakic intraocular lens(Visian implantable collamer lens(ICL),STAAR Surgical)implantation.Methods:This study comprised 121 eyes of 121 consecutive patients undergoing ICL surgery through a 3.0-mm temporal or superior clear corneal incision.The magnitude and the axis of corneal astigmatism preoperatively and 3 months postoperatively were measured using an automated keratometer.The M-SIA and the SVM-SIA were determined according to the incision site.Results:The magnitude of corneal astigmatism significantly increased from 1.23±0.59 D preoperatively to 1.46±0.72 D postoperatively in the temporal incision group(Wilcoxon signed-rank test,P<0.001),but it significantly decreased from 1.09±0.36 D preoperatively to 0.86±0.41 D postoperatively in the superior incision group(P<0.001).The M-SIA was 0.48±0.30 D,and the SVM-SIA was 0.23±0.52 D at a meridian of 82°in the temporal incision group.The M-SIA was 0.57±0.30 D,and the SVM-SIA was 0.47±0.45 D at a meridian of 1°in the superior incision group.Conclusions:ICL implantation induces the M-SIA by approximately 0.5 D,but the SVM-SIA decreased to 50%and 80%of the M-SIA in magnitude through temporal and superior incisions,respectively.The direction of the SVM-SIA showed a tendency toward corneal flattening to the incisional site.It should be noted that the M-SIA is somewhat different from the SVM-SIA according to the incision site.
文摘BackgroundTo compare the arithmetic mean (M-SIA) and the summated vector mean of surgically induced astigmatism (SVM-SIA) according to the incision site after phakic intraocular lens (Visian implantable collamer lens (ICL), STAAR Surgical) implantation.MethodsThis study comprised 121 eyes of 121 consecutive patients undergoing ICL surgery through a 3.0-mm temporal or superior clear corneal incision. The magnitude and the axis of corneal astigmatism preoperatively and 3 months postoperatively were measured using an automated keratometer. The M-SIA and the SVM-SIA were determined according to the incision site.ResultsThe magnitude of corneal astigmatism significantly increased from 1.23 ± 0.59 D preoperatively to 1.46 ± 0.72 D postoperatively in the temporal incision group (Wilcoxon signed-rank test, P < 0.001), but it significantly decreased from 1.09 ± 0.36 D preoperatively to 0.86 ± 0.41 D postoperatively in the superior incision group (P < 0.001). The M-SIA was 0.48 ± 0.30 D, and the SVM-SIA was 0.23 ± 0.52 D at a meridian of 82° in the temporal incision group. The M-SIA was 0.57 ± 0.30 D, and the SVM-SIA was 0.47 ± 0.45 D at a meridian of 1° in the superior incision group.ConclusionsICL implantation induces the M-SIA by approximately 0.5 D, but the SVM-SIA decreased to 50% and 80% of the M-SIA in magnitude through temporal and superior incisions, respectively. The direction of the SVM-SIA showed a tendency toward corneal flattening to the incisional site. It should be noted that the M-SIA is somewhat different from the SVM-SIA according to the incision site.