The integration of distributed generation brings in new challenges for the operation of distribution networks,including out-of-limit voltage and power flow control.Soft open points(SOP)are new power electronic devices...The integration of distributed generation brings in new challenges for the operation of distribution networks,including out-of-limit voltage and power flow control.Soft open points(SOP)are new power electronic devices that can flexibly control active and reactive power flows.With the exception of active power output,photovoltaic(PV)devices can provide reactive power compensation through an inverter.Thus,a synergetic optimization operation method for SOP and PV in a distribution network is proposed.A synergetic optimization model was developed.The voltage deviation,network loss,and ratio of photovoltaic abandonment were selected as the objective functions.The PV model was improved by considering the three reactive power output modes of the PV inverter.Both the load fluctuation and loss of the SOP were considered.Three multi-objective optimization algorithms were used,and a compromise optimal solution was calculated.Case studies were conducted using an IEEE 33-node system.The simulation results indicated that the SOP and PVs complemented each other in terms of active power transmission and reactive power compensation.Synergetic optimization improves power control capability and flexibility,providing better power quality and PV consumption rate.展开更多
BACKGROUND: Early identification of patients requiring ventilator support will be beneficial for the outcomes of botulism. The present study aimed to establish a new scoring system to predict mechanical ventilation(MV...BACKGROUND: Early identification of patients requiring ventilator support will be beneficial for the outcomes of botulism. The present study aimed to establish a new scoring system to predict mechanical ventilation(MV) for botulism patients.METHODS: A single-center retrospective study was conducted to identify risk factors associated with MV in botulism patients from 2007 to 2022. Univariate analysis and multivariate logistic regression analysis were used to screen out risk factors for constructing a prognostic scoring system. The area under the receiver operating characteristic(ROC) curve was calculated.RESULTS: A total of 153 patients with botulism(66 males and 87 females, with an average age of 43 years) were included. Of these, 49 patients(32.0%) required MV, including 21(13.7%) with invasive ventilation and 28(18.3%) with non-invasive ventilation. Multivariate analysis revealed that botulinum toxin type, pneumonia, incubation period, degree of hypoxia, and severity of muscle involvement were independent risk factors for MV. These risk factors were incorporated into a multivariate logistic regression analysis to establish a prognostic scoring system. Each risk factor was scored by allocating a weight based on its regression coefficient and rounded to whole numbers for practical utilization([botulinum toxin type A: 1], [pneumonia: 2], [incubation period ≤1 day: 2], [hypoxia <90%: 2], [severity of muscle involvement: grade Ⅱ, 3;gradeⅢ, 7;grade IV, 11]). The scoring system achieved an area under the ROC curve of 0.82(95% CI 0.75–0.89, P<0.001). At the optimal threshold of 9, the scoring system achieved a sensitivity of 83.7% and a specificity of 70.2%.CONCLUSION: Our study identified botulinum toxin type, pneumonia, incubation period, degree of hypoxia, and severity of muscle involvement as independent risk factors for MV in botulism patients. A score ≥9 in our scoring system is associated with a higher likelihood of requiring MV in botulism patients. This scoring system needs to be validated externally before it can be applied in clinical settings.展开更多
Oxidative stress has been associated with a number of physiological problems in swine,including reduced production efficiency.Recently,although there has been increased research into regulatory mechanisms and antioxid...Oxidative stress has been associated with a number of physiological problems in swine,including reduced production efficiency.Recently,although there has been increased research into regulatory mechanisms and antioxidant strategies in relation to oxidative stress-induced pig production,it remains so far largely unsuccessful to develop accurate models and nutritional strategies for specific oxidative stress factors.Here,we discuss the dose and dose intensity of the causes of oxidative stress involving physiological,environmental and dietary factors,recent research models and the antioxidant strategies to provide theoretical guidance for future oxidative stress research in swine.展开更多
Wind-photovoltaic(PV)-hydrogen-storage multi-agent energy systems are expected to play an important role in promoting renewable power utilization and decarbonization.In this study,a coordinated operation method was pr...Wind-photovoltaic(PV)-hydrogen-storage multi-agent energy systems are expected to play an important role in promoting renewable power utilization and decarbonization.In this study,a coordinated operation method was proposed for a wind-PVhydrogen-storage multi-agent energy system.First,a coordinated operation model was formulated for each agent considering peer-to-peer power trading.Second,a coordinated operation interactive framework for a multi-agent energy system was proposed based on the theory of the alternating direction method of multipliers.Third,a distributed interactive algorithm was proposed to protect the privacy of each agent and solve coordinated operation strategies.Finally,the effectiveness of the proposed coordinated operation method was tested on multi-agent energy systems with different structures,and the operational revenues of the wind power,PV,hydrogen,and energy storage agents of the proposed coordinated operation model were improved by approximately 59.19%,233.28%,16.75%,and 145.56%,respectively,compared with the independent operation model.展开更多
基金supported by the Science and Technology Project of SGCC(kj2022-075).
文摘The integration of distributed generation brings in new challenges for the operation of distribution networks,including out-of-limit voltage and power flow control.Soft open points(SOP)are new power electronic devices that can flexibly control active and reactive power flows.With the exception of active power output,photovoltaic(PV)devices can provide reactive power compensation through an inverter.Thus,a synergetic optimization operation method for SOP and PV in a distribution network is proposed.A synergetic optimization model was developed.The voltage deviation,network loss,and ratio of photovoltaic abandonment were selected as the objective functions.The PV model was improved by considering the three reactive power output modes of the PV inverter.Both the load fluctuation and loss of the SOP were considered.Three multi-objective optimization algorithms were used,and a compromise optimal solution was calculated.Case studies were conducted using an IEEE 33-node system.The simulation results indicated that the SOP and PVs complemented each other in terms of active power transmission and reactive power compensation.Synergetic optimization improves power control capability and flexibility,providing better power quality and PV consumption rate.
基金funded by the Medical Science Research Project of Hebei Provincial Health and Health Commission(20221073).
文摘BACKGROUND: Early identification of patients requiring ventilator support will be beneficial for the outcomes of botulism. The present study aimed to establish a new scoring system to predict mechanical ventilation(MV) for botulism patients.METHODS: A single-center retrospective study was conducted to identify risk factors associated with MV in botulism patients from 2007 to 2022. Univariate analysis and multivariate logistic regression analysis were used to screen out risk factors for constructing a prognostic scoring system. The area under the receiver operating characteristic(ROC) curve was calculated.RESULTS: A total of 153 patients with botulism(66 males and 87 females, with an average age of 43 years) were included. Of these, 49 patients(32.0%) required MV, including 21(13.7%) with invasive ventilation and 28(18.3%) with non-invasive ventilation. Multivariate analysis revealed that botulinum toxin type, pneumonia, incubation period, degree of hypoxia, and severity of muscle involvement were independent risk factors for MV. These risk factors were incorporated into a multivariate logistic regression analysis to establish a prognostic scoring system. Each risk factor was scored by allocating a weight based on its regression coefficient and rounded to whole numbers for practical utilization([botulinum toxin type A: 1], [pneumonia: 2], [incubation period ≤1 day: 2], [hypoxia <90%: 2], [severity of muscle involvement: grade Ⅱ, 3;gradeⅢ, 7;grade IV, 11]). The scoring system achieved an area under the ROC curve of 0.82(95% CI 0.75–0.89, P<0.001). At the optimal threshold of 9, the scoring system achieved a sensitivity of 83.7% and a specificity of 70.2%.CONCLUSION: Our study identified botulinum toxin type, pneumonia, incubation period, degree of hypoxia, and severity of muscle involvement as independent risk factors for MV in botulism patients. A score ≥9 in our scoring system is associated with a higher likelihood of requiring MV in botulism patients. This scoring system needs to be validated externally before it can be applied in clinical settings.
基金supported by Guangzhou Science and Technology Planning Project(2023A04J0131)Special fund for scientific innovation strategyconstruction of high level Academy of Agriculture Science(R2020PY-JG009,R2022PY-QY007,202106TD)+2 种基金China Agriculture Research System-CARS-35the Project of Swine Innovation Team in Guangdong Modern Agricultural Research System(2022KJ126)Special Fund for Rural Revitalization Strategy of Guangdong(2023TS-3),China。
文摘Oxidative stress has been associated with a number of physiological problems in swine,including reduced production efficiency.Recently,although there has been increased research into regulatory mechanisms and antioxidant strategies in relation to oxidative stress-induced pig production,it remains so far largely unsuccessful to develop accurate models and nutritional strategies for specific oxidative stress factors.Here,we discuss the dose and dose intensity of the causes of oxidative stress involving physiological,environmental and dietary factors,recent research models and the antioxidant strategies to provide theoretical guidance for future oxidative stress research in swine.
基金supported by the Key Research and Development Program of Jiangsu Provincial Department of Science and Technology(BE2020081).
文摘Wind-photovoltaic(PV)-hydrogen-storage multi-agent energy systems are expected to play an important role in promoting renewable power utilization and decarbonization.In this study,a coordinated operation method was proposed for a wind-PVhydrogen-storage multi-agent energy system.First,a coordinated operation model was formulated for each agent considering peer-to-peer power trading.Second,a coordinated operation interactive framework for a multi-agent energy system was proposed based on the theory of the alternating direction method of multipliers.Third,a distributed interactive algorithm was proposed to protect the privacy of each agent and solve coordinated operation strategies.Finally,the effectiveness of the proposed coordinated operation method was tested on multi-agent energy systems with different structures,and the operational revenues of the wind power,PV,hydrogen,and energy storage agents of the proposed coordinated operation model were improved by approximately 59.19%,233.28%,16.75%,and 145.56%,respectively,compared with the independent operation model.