The Effects of Voltage and Suction Line Heat Exchanger on a Domestic Refrigerator's Performance
1
作者 Xerri Stefan farrugia mario 《Journal of Energy and Power Engineering》 2016年第10期606-614,共9页
This experimental analysis shows the measured reduction in energy consumption as well as the effects of voltage on cycle temperatures, pressures, flow rates and also compressor speed (revolutions per minute). The do... This experimental analysis shows the measured reduction in energy consumption as well as the effects of voltage on cycle temperatures, pressures, flow rates and also compressor speed (revolutions per minute). The domestic refrigerator used R134a as refrigerant. Two energy consumption procedures were adapted from the JIS and ISO standards. The biggest difference between two standards is that the fridge is not opened in the ISO test while it is opened a number of times in the JIS test. The tests were carried out between 190 V and 250 V in steps of 10 V. The reduction in energy consumption was of 49.78 W-h per day or 6.27% of the total consumption. The experiments also showed that the voltage drop resulted in only a small rpm drop which in turn did not result in a noticeable refrigerant flow-rate change. Consequently the temperatures and pressures were not affected. 展开更多
关键词 REFRIGERATION voltage optimization energy consumption capillary-tube/suction-line heat exchanger.