BACKGROUND: This study aims to investigate whether small balloon aortic valvuloplasty(BAV) reduces the need for permanent pacemaker implantation (PPMI) after transcatheter aortic valveimplantation (TAVI).METHODS: This...BACKGROUND: This study aims to investigate whether small balloon aortic valvuloplasty(BAV) reduces the need for permanent pacemaker implantation (PPMI) after transcatheter aortic valveimplantation (TAVI).METHODS: This was a retrospective analysis using data from our local TAVI database. SmallBAV was defined as a small balloon size (=18 mm) pre-dilatation. Normal BAV was defined as aballoon size >18 mm. The primary endpoint was the incidence of new PPMI.RESULTS: Of 99 consecutive TAVI patients, five patients were excluded due to pre-existingpermanent pacemaker. Patients in the small BAV group (n=57) had a signifi cantly lower PPMI ratecompared with the normal BAV group (n=37) (3.5% vs. 18.9%, P=0.026). Moderate or severe aorticvalve regurgitation post-procedure was similar between the small BAV and normal BAV groups (5.3%vs. 8.1%, P=0.480);likewise, the mean aortic gradient post-procedure did not differ significantly(11.5±5.2 mmHg vs. 12.2±7.3 mmHg, 1 mmHg=0.133 kPa, P=0.580) between the groups. Devicesuccess rates were also similar (94.7% vs. 91.8%, P=0.680). In multivariable analysis, small BAV(P=0.027), the ratio of prosthesis diameter to annulus diameter (P=0.048), and mean aortic gradientby echo in the basement (P=0.021) were independent predictors of PPMI.CONCLUSIONS: The small BAV strategy is associated with a low rate of permanentpacemaker implantation after transcatheter self-expanding valve implantation in this single-centerobservational study.展开更多
基金supported by National Key R & D Plan(2017YFC1104202).
文摘BACKGROUND: This study aims to investigate whether small balloon aortic valvuloplasty(BAV) reduces the need for permanent pacemaker implantation (PPMI) after transcatheter aortic valveimplantation (TAVI).METHODS: This was a retrospective analysis using data from our local TAVI database. SmallBAV was defined as a small balloon size (=18 mm) pre-dilatation. Normal BAV was defined as aballoon size >18 mm. The primary endpoint was the incidence of new PPMI.RESULTS: Of 99 consecutive TAVI patients, five patients were excluded due to pre-existingpermanent pacemaker. Patients in the small BAV group (n=57) had a signifi cantly lower PPMI ratecompared with the normal BAV group (n=37) (3.5% vs. 18.9%, P=0.026). Moderate or severe aorticvalve regurgitation post-procedure was similar between the small BAV and normal BAV groups (5.3%vs. 8.1%, P=0.480);likewise, the mean aortic gradient post-procedure did not differ significantly(11.5±5.2 mmHg vs. 12.2±7.3 mmHg, 1 mmHg=0.133 kPa, P=0.580) between the groups. Devicesuccess rates were also similar (94.7% vs. 91.8%, P=0.680). In multivariable analysis, small BAV(P=0.027), the ratio of prosthesis diameter to annulus diameter (P=0.048), and mean aortic gradientby echo in the basement (P=0.021) were independent predictors of PPMI.CONCLUSIONS: The small BAV strategy is associated with a low rate of permanentpacemaker implantation after transcatheter self-expanding valve implantation in this single-centerobservational study.