期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
装备试验鉴定计量保障方案研究
1
作者 刘岩 胡晓粉 +1 位作者 张春洋 边飞龙 《计量与测试技术》 2024年第1期61-64,共4页
本文在分析装备试验鉴定计量保障方案的研究目的、基本内涵和建设思路的基础上,提出该方案的总体规划和实施步骤,从而满足试验任务全过程的计量监督管理和试验设备设施量值的溯源要求,确保试验鉴定过程计量单位统一和量值准确可靠,有效... 本文在分析装备试验鉴定计量保障方案的研究目的、基本内涵和建设思路的基础上,提出该方案的总体规划和实施步骤,从而满足试验任务全过程的计量监督管理和试验设备设施量值的溯源要求,确保试验鉴定过程计量单位统一和量值准确可靠,有效发挥军事计量建设对提高装备试验鉴定质量和可靠性的重要作用。 展开更多
关键词 装备 试验鉴定 计量保障
在线阅读 下载PDF
Conjugate Heat Transfer Analysis of an Ultrasonic Molten Metal Treatment System 被引量:1
2
作者 ZHU Youli bian feilong +1 位作者 WANG Yanli ZHAO Qian 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2014年第5期986-991,共6页
In piezoceramic ultrasonic devices,the piezoceramic stacks may fail permanently or function improperly if their working temperatures overstep the Curie temperature of the piezoceramic material.While the end of the hor... In piezoceramic ultrasonic devices,the piezoceramic stacks may fail permanently or function improperly if their working temperatures overstep the Curie temperature of the piezoceramic material.While the end of the horn usually serves near the melting point of the molten metal and is enclosed in an airtight chamber,so that it is difficult to experimentally measure the temperature of the transducer and its variation with time,which bring heavy difficulty to the design of the ultrasonic molten metal treatment system.To find a way out,conjugate heat transfer analysis of an ultrasonic molten metal treatment system is performed with coupled fluid and heat transfer finite element method.In modeling of the system,the RNG model and the SIMPLE algorithm are adopted for turbulence and nonlinear coupling between the momentum equation and the energy equation.Forced air cooling as well as natural air cooling is analyzed to compare the difference of temperature evolution.Numerical results show that,after about 350 s of working time,temperatures in the surface of the ceramic stacks in forced air cooling drop about 7 K compared with that in natural cooling.At 240 s,The molten metal surface emits heat radiation with a maximum rate of about 19 036 W/m2,while the heat insulation disc absorbs heat radiation at a maximum rate of about 7922 W/m2,which indicates the effectiveness of heat insulation of the asbestos pad.Transient heat transfer film coefficient and its distribution,which are difficult to be measured experimentally are also obtained through numerical simulation.At 240 s,the heat transfer film coefficient in the surface of the transducer ranges from–17.86 to 20.17 W/(m2?K).Compared with the trial and error method based on the test,the proposed research provides a more effective way in the design and analysis of the temperature control of the molten metal treatment system. 展开更多
关键词 conjugate heat transfer finite element analysis ultrasonic molten metal treatment computational fluid dynamics
在线阅读 下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部