A reliable approach based on a multi-verse optimization algorithm(MVO)for designing load frequency control incorporated in multi-interconnected power system comprising wind power and photovoltaic(PV)plants is presente...A reliable approach based on a multi-verse optimization algorithm(MVO)for designing load frequency control incorporated in multi-interconnected power system comprising wind power and photovoltaic(PV)plants is presented in this paper.It has been applied for optimizing the control parameters of the load frequency controller(LFC)of the multi-source power system(MSPS).The MSPS includes thermal,gas,and hydro power plants for energy generation.Moreover,the MSPS is integrated with renewable energy sources(RES).The MVO algorithm is applied to acquire the ideal parameters of the controller for controlling a single area and a multi-area MSPS integrated with RES.HVDC link is utilized in shunt with AC multi-areas interconnection tie line.The proposed scheme has achieved robust performance against the disturbance in loading conditions,variation of system parameters,and size of step load perturbation(SLP).Meanwhile,the simulation outcomes showed a good dynamic performance of the proposed controller.展开更多
National and international policies encourage increased penetration of solar and wind energy into electrical networks in order to reduce greenhouse gas emission. Solar radiation and wind speed variations complicate th...National and international policies encourage increased penetration of solar and wind energy into electrical networks in order to reduce greenhouse gas emission. Solar radiation and wind speed variations complicate the integration of wind and solar generation into power systems and delay the transition of these sources from centralized to distributed energy sources. The increased penetration of nontraditional energy sources into the electric grid stimulates the demand for large capacities in the field of energy storage. A mathematical model, which describes the operation of a proposed hybrid system, including solar PV, wind energy, and a pumped storage hydroelectric power plant is developed in this paper. This hydropower plant utilizes seawater as a lower reservoir, and only a tank has to be built in order to reduce the installation cost of the storing system. The pumped storage power plant used for compensation of the variation of the output energy from the PV and wind power plants by discharging water from the upper reservoir, which is previously pumped in the case of surplus energy from PV and wind turbine power plants. The impact of the proposed system on the grid utility is investigated in accordance with the values of energy exchange(deficits and surpluses of energy) between the considered hybrid system and the grid. The optimum design is determined by the pump and turbine capacities, upper reservoir volume, and the volume of water left in the tank for emergencies. Different scenarios of the optimum operations are presented for analysis. The results obtained from the examined scenarios indicate the ability of such a hybrid energy system to reduce the exchange of energy with the grid. This paper indicates the technical feasibility of seawater pumpedstorage hydropower plant for increasing the Egyptian national grid’s ability to accept high integration of renewable energy sources.展开更多
基金This project was supported by the Deanship of Scientific Research at Prince Sattam Bin Abdulaziz University under the research project No 2020/01/11742.
文摘A reliable approach based on a multi-verse optimization algorithm(MVO)for designing load frequency control incorporated in multi-interconnected power system comprising wind power and photovoltaic(PV)plants is presented in this paper.It has been applied for optimizing the control parameters of the load frequency controller(LFC)of the multi-source power system(MSPS).The MSPS includes thermal,gas,and hydro power plants for energy generation.Moreover,the MSPS is integrated with renewable energy sources(RES).The MVO algorithm is applied to acquire the ideal parameters of the controller for controlling a single area and a multi-area MSPS integrated with RES.HVDC link is utilized in shunt with AC multi-areas interconnection tie line.The proposed scheme has achieved robust performance against the disturbance in loading conditions,variation of system parameters,and size of step load perturbation(SLP).Meanwhile,the simulation outcomes showed a good dynamic performance of the proposed controller.
文摘National and international policies encourage increased penetration of solar and wind energy into electrical networks in order to reduce greenhouse gas emission. Solar radiation and wind speed variations complicate the integration of wind and solar generation into power systems and delay the transition of these sources from centralized to distributed energy sources. The increased penetration of nontraditional energy sources into the electric grid stimulates the demand for large capacities in the field of energy storage. A mathematical model, which describes the operation of a proposed hybrid system, including solar PV, wind energy, and a pumped storage hydroelectric power plant is developed in this paper. This hydropower plant utilizes seawater as a lower reservoir, and only a tank has to be built in order to reduce the installation cost of the storing system. The pumped storage power plant used for compensation of the variation of the output energy from the PV and wind power plants by discharging water from the upper reservoir, which is previously pumped in the case of surplus energy from PV and wind turbine power plants. The impact of the proposed system on the grid utility is investigated in accordance with the values of energy exchange(deficits and surpluses of energy) between the considered hybrid system and the grid. The optimum design is determined by the pump and turbine capacities, upper reservoir volume, and the volume of water left in the tank for emergencies. Different scenarios of the optimum operations are presented for analysis. The results obtained from the examined scenarios indicate the ability of such a hybrid energy system to reduce the exchange of energy with the grid. This paper indicates the technical feasibility of seawater pumpedstorage hydropower plant for increasing the Egyptian national grid’s ability to accept high integration of renewable energy sources.