为研究棒尖端外形对低气压下棒-板间隙直流放电特性的影响,利用低气压放电试验平台在2~20 k Pa气压下对锥尖头、半球头以及平头3种棒电极在100~300 mm间隙内进行直流电压放电试验,并通过仿真对不同棒尖端的放电特性试验结果进行验证。...为研究棒尖端外形对低气压下棒-板间隙直流放电特性的影响,利用低气压放电试验平台在2~20 k Pa气压下对锥尖头、半球头以及平头3种棒电极在100~300 mm间隙内进行直流电压放电试验,并通过仿真对不同棒尖端的放电特性试验结果进行验证。结果表明:棒尖端外形会对低气压下棒-板间隙的放电电压产生影响,击穿电压幅值从小到大依次为:锥尖头、半球头、平头;锥尖头棒和平头棒尖端存在局部电场极不均匀点,而半球头棒尖端电场分布较为均匀;随着气压的上升,棒-板间隙的U50%-P曲线呈稳定上升趋势。展开更多
The mechanism of gas discharge in refrigeration temperature range is still not clear. N2, CF4, 20% CF4+N2 and 50%CF4+50%N2 binary gas mixtures were tested under the conditions of –153–25 ℃ and 50–2000 Pa. The ex...The mechanism of gas discharge in refrigeration temperature range is still not clear. N2, CF4, 20% CF4+N2 and 50%CF4+50%N2 binary gas mixtures were tested under the conditions of –153–25 ℃ and 50–2000 Pa. The experimental results show that the minimum of Paschen curves of all test samples shifts to low pressure, from 500 Pa to 200 Pa. The value of Paschen curve minimum of N2 shows remarkable fluctuation. This fluctuation is explained by molecule agglomeration and electronic mean energy. The fluctuation decreases with the increasing mixing ratio of CF4. What’s more, the value of Paschen curve minimum of CF4 decreases with temperature. This phenomenon is ascribed to attach-radiation and secondary process.展开更多
文摘为研究棒尖端外形对低气压下棒-板间隙直流放电特性的影响,利用低气压放电试验平台在2~20 k Pa气压下对锥尖头、半球头以及平头3种棒电极在100~300 mm间隙内进行直流电压放电试验,并通过仿真对不同棒尖端的放电特性试验结果进行验证。结果表明:棒尖端外形会对低气压下棒-板间隙的放电电压产生影响,击穿电压幅值从小到大依次为:锥尖头、半球头、平头;锥尖头棒和平头棒尖端存在局部电场极不均匀点,而半球头棒尖端电场分布较为均匀;随着气压的上升,棒-板间隙的U50%-P曲线呈稳定上升趋势。
基金Project(51277063) supported by the National Natural Science Foundation of ChinaProject(51407013) supported in part by the National Natural Science Foundation of China
文摘The mechanism of gas discharge in refrigeration temperature range is still not clear. N2, CF4, 20% CF4+N2 and 50%CF4+50%N2 binary gas mixtures were tested under the conditions of –153–25 ℃ and 50–2000 Pa. The experimental results show that the minimum of Paschen curves of all test samples shifts to low pressure, from 500 Pa to 200 Pa. The value of Paschen curve minimum of N2 shows remarkable fluctuation. This fluctuation is explained by molecule agglomeration and electronic mean energy. The fluctuation decreases with the increasing mixing ratio of CF4. What’s more, the value of Paschen curve minimum of CF4 decreases with temperature. This phenomenon is ascribed to attach-radiation and secondary process.