In order to improve the efficiency of a geothermal power plant, oil wells in the high water cut stage were used as geothermal wells, thereby improving the recovery ratio and economic benefit. A new function that refle...In order to improve the efficiency of a geothermal power plant, oil wells in the high water cut stage were used as geothermal wells, thereby improving the recovery ratio and economic benefit. A new function that reflects both the technical and economic performances was put forward and used as the objective function. An organic Rankine cycle (ORC) was analyzed through the energetic and exergetic analyses, and the reasons for low efficiency were pinpointed. Results indicate that geothermal water directly transferring heat to the working fluid reduces energy dissipation and increases cycle efficiencies. The net power output with an internal heat exchanger (IHE) is averagely 5.3% higher than that without an IHE. R601a and R601 can be used to replace R123 for geothermal water below 110℃. Moreover, the modified ORC dramatically outperforms the actual one.展开更多
The orientation strategy of side pipe and the heat transfer performance of six ground heat exchangers(GHEs) were optimized by numerical simulation,with soil being treated as a porous medium.An experiment on the heat t...The orientation strategy of side pipe and the heat transfer performance of six ground heat exchangers(GHEs) were optimized by numerical simulation,with soil being treated as a porous medium.An experiment on the heat transfer of four GHEs was carried out in 2010.Results indicate that the velocity field is disturbed by GHEs.The optimal orientation strategy of side pipe is that the upward pipe is located upstream and the downward pipe downstream.The space between GHEs should be appropriately adjusted,depending on the direction and flow velocity.Groups of GHEs should be installed perpendicular to the mainstream in a single row,but if the acreage does not meet the requirements,GHEs should be installed in staggered multiple rows.Fewer GHEs parallel to the mainstream strengthen the heat transfer.Moreover,numerical results agree well with the test data,with the maximum relative error being less than 7.7%.展开更多
Organic Rankine cycle(ORC) is applicable for the heat-work conversion. Whereas, there also exist a lot issues that influence the efficiency and the cost of the system. In this work, eleven pure working fluids(as categ...Organic Rankine cycle(ORC) is applicable for the heat-work conversion. Whereas, there also exist a lot issues that influence the efficiency and the cost of the system. In this work, eleven pure working fluids(as categorized into alkanes, and fluorinated alkanes) are investigated based on the first and second law of thermodynamics. The major objective is to obtain the most suitable working fluid for the latent heat source. The results show that the working fluid is an important factor of the system performance. The heat absorption of the working fluid in the evaporator is inversely proportional to the evaporating temperature, but the thermal and exergetic efficiencies are just the opposite. RC318 has the highest net power output and the lowest outlet temperature of the heat source, but its global warming potential(GWP) value is too high. The cyclohexane shows the highest thermal efficiency among the fluids investigated. Moreover, the figure of merit(FOM) of the isobutane is higher than that of other working fluids. Overall, the cyclohexane shows that the optimal comprehensive performance is more feasible for medium grade heat source in engineering applications.展开更多
In order to select the appropriate working fluids and optimize parameters for medium-temperature geothermally-powered organic Rankine cycle(ORC), R245 fa is mixed with R601 a at geothermal water temperature of 110 ℃....In order to select the appropriate working fluids and optimize parameters for medium-temperature geothermally-powered organic Rankine cycle(ORC), R245 fa is mixed with R601 a at geothermal water temperature of 110 ℃. Based on thermodynamics, the characteristics of mixture and its influence on the performance of ORC under different evaporating temperatures and composition proportions are analyzed. Results show that the zeotropic mixture R245fa/R601a(0.4/0.6) has the highest performance. When the evaporating temperature reaches 67 ℃, the outlet temperature of geothermal water is 61 ℃, the net power output is the highest and the thermal efficiency is about 9%.展开更多
A comparison on subcritical and transcritical organic Rankine cycle(ORC) system with a heat source of 110 ℃ geothermal water was presented. The net power output, thermal and exergy efficiencies and the products of ...A comparison on subcritical and transcritical organic Rankine cycle(ORC) system with a heat source of 110 ℃ geothermal water was presented. The net power output, thermal and exergy efficiencies and the products of the heat transfer coefficient(U) and the total heat exchange area(A)(UA values) were calculated for parametric optimization. Nine candidate working fluids were investigated and compared. Under the given conditions, transcritical systems have higher net power outputs than subcritical ones. The highest net power output of transcritical systems is 18.63 k W obtained by R218, and that of subcritical systems is 13.57 k W obtained by R600 a. Moreover, with the increase of evaporating pressure, the thermal and exergy efficiencies of transcritical systems increase at first and then decrease, but the efficiencies of subcritical ones increase. As a result, the efficiencies of transcritical systems cannot always outperform those of the subcritical ones. However, the subcritical systems have lower minimum UA values and lower expansion ratios than the transcritical ones at the maximum net power output. In addition, the transcritical cycles have higher expansion ratios than the subcritical ones at their maximum net power output.展开更多
基金Project(2012AA052804) supported by the National High Technology Research and Development Program of China
文摘In order to improve the efficiency of a geothermal power plant, oil wells in the high water cut stage were used as geothermal wells, thereby improving the recovery ratio and economic benefit. A new function that reflects both the technical and economic performances was put forward and used as the objective function. An organic Rankine cycle (ORC) was analyzed through the energetic and exergetic analyses, and the reasons for low efficiency were pinpointed. Results indicate that geothermal water directly transferring heat to the working fluid reduces energy dissipation and increases cycle efficiencies. The net power output with an internal heat exchanger (IHE) is averagely 5.3% higher than that without an IHE. R601a and R601 can be used to replace R123 for geothermal water below 110℃. Moreover, the modified ORC dramatically outperforms the actual one.
文摘The orientation strategy of side pipe and the heat transfer performance of six ground heat exchangers(GHEs) were optimized by numerical simulation,with soil being treated as a porous medium.An experiment on the heat transfer of four GHEs was carried out in 2010.Results indicate that the velocity field is disturbed by GHEs.The optimal orientation strategy of side pipe is that the upward pipe is located upstream and the downward pipe downstream.The space between GHEs should be appropriately adjusted,depending on the direction and flow velocity.Groups of GHEs should be installed perpendicular to the mainstream in a single row,but if the acreage does not meet the requirements,GHEs should be installed in staggered multiple rows.Fewer GHEs parallel to the mainstream strengthen the heat transfer.Moreover,numerical results agree well with the test data,with the maximum relative error being less than 7.7%.
基金Project(51406130) supported by the National Natural Science Foundation of China
文摘Organic Rankine cycle(ORC) is applicable for the heat-work conversion. Whereas, there also exist a lot issues that influence the efficiency and the cost of the system. In this work, eleven pure working fluids(as categorized into alkanes, and fluorinated alkanes) are investigated based on the first and second law of thermodynamics. The major objective is to obtain the most suitable working fluid for the latent heat source. The results show that the working fluid is an important factor of the system performance. The heat absorption of the working fluid in the evaporator is inversely proportional to the evaporating temperature, but the thermal and exergetic efficiencies are just the opposite. RC318 has the highest net power output and the lowest outlet temperature of the heat source, but its global warming potential(GWP) value is too high. The cyclohexane shows the highest thermal efficiency among the fluids investigated. Moreover, the figure of merit(FOM) of the isobutane is higher than that of other working fluids. Overall, the cyclohexane shows that the optimal comprehensive performance is more feasible for medium grade heat source in engineering applications.
基金Supported by the National High Technology Research and Development Program of China("863" Program,No.2012AA053001)
文摘In order to select the appropriate working fluids and optimize parameters for medium-temperature geothermally-powered organic Rankine cycle(ORC), R245 fa is mixed with R601 a at geothermal water temperature of 110 ℃. Based on thermodynamics, the characteristics of mixture and its influence on the performance of ORC under different evaporating temperatures and composition proportions are analyzed. Results show that the zeotropic mixture R245fa/R601a(0.4/0.6) has the highest performance. When the evaporating temperature reaches 67 ℃, the outlet temperature of geothermal water is 61 ℃, the net power output is the highest and the thermal efficiency is about 9%.
基金Project(2012AA053001) supported by the National High Technology Research and Development Program of China
文摘A comparison on subcritical and transcritical organic Rankine cycle(ORC) system with a heat source of 110 ℃ geothermal water was presented. The net power output, thermal and exergy efficiencies and the products of the heat transfer coefficient(U) and the total heat exchange area(A)(UA values) were calculated for parametric optimization. Nine candidate working fluids were investigated and compared. Under the given conditions, transcritical systems have higher net power outputs than subcritical ones. The highest net power output of transcritical systems is 18.63 k W obtained by R218, and that of subcritical systems is 13.57 k W obtained by R600 a. Moreover, with the increase of evaporating pressure, the thermal and exergy efficiencies of transcritical systems increase at first and then decrease, but the efficiencies of subcritical ones increase. As a result, the efficiencies of transcritical systems cannot always outperform those of the subcritical ones. However, the subcritical systems have lower minimum UA values and lower expansion ratios than the transcritical ones at the maximum net power output. In addition, the transcritical cycles have higher expansion ratios than the subcritical ones at their maximum net power output.